Disposable insulin syringe reuse and aseptic practices in diabetic patients
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Diabetic patients are traditionally taught to discard plastic syringe/needle units after a single use and to employ aseptic technique for administering insulin injections. We surveyed 87 diabetic outpatients for compliance with aseptic recommendations. We then studied prospectively the effects of reusing disposable syringes in 56 diabetic patients who reused syringes a mean of 6.6 times for 8.3 months and an aggregate of 23,664 injections. Almost half (49%) of diabetic patients in a combined university clinic and private practice reused supposedly disposable insulin syringes a mean of 3.9 times. Compliance with standard aseptic precautions was poor, with only 29% of patients following recommended practices. No adverse effect of syringe reuse was identified. The authors conclude that diabetic patients frequently reuse disposable syringes, without apparent harmful effect.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Insulin pens may allow people with vision impairment or dexterity issues to dose insulin accurately (149-151), and insulin injection aids are also available to help with these issues.”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [151]
Citations
Cites
EXPERIMENTAL STAPHYLOCOCCAL INFECTIONS IN THE SKIN OF MAN
Elek, S. D. (1956) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1956.tb36626.x · Cited by 272
STERILITY PROBLEMS AND DIABETIC
Drayer, N. (1978) · University of Groningen research database (University of Groningen / Centre for Information Technology) · Cited by 74
IS SKIN PREPARATION NECESSARY BEFORE INSULIN INJECTION?
Koivisto, V., & Felig, P. (1978) · The Lancet · doi:10.1016/s0140-6736(78)90916-9 · Cited by 65
ROUTINE SKIN PREPARATION BEFORE INJECTION
Dann, T. C. (1969) · The Lancet · doi:10.1016/s0140-6736(69)92405-2 · Cited by 58
Treatment of Diabetes Mellitus.
(1941) · Archives of Internal Medicine · doi:10.1001/archinte.1941.00200050203015 · Cited by 58
Disposable syringes for insulin injection.
Greenough, A., Cockcroft, P. M., & Bloom, A. (1979) · BMJ · doi:10.1136/bmj.1.6176.1467 · Cited by 51
Treatment of Diabetes Mellitus
Bonequi, C. C. (1927) · Postgraduate Medical Journal · doi:10.1136/pgmj.2.19.110 · Cited by 38
Multiple Use of Disposable Insulin Syringe-Needle Units
Hodge, R. H. (1980) · JAMA · doi:10.1001/jama.1980.03310030042024 · Cited by 37
SAFETY OF REUSING DISPOSABLE PLASTIC INSULIN SYRINGES
Collins, B. J., Spence, B., Richardson, S. G., Hunter, J., Son, & Nelson, J. K. (1983) · The Lancet · doi:10.1016/s0140-6736(83)92812-x · Cited by 33
Traditional Insulin-Use Practices and the Incidence of Bacterial Contamination and Infection
Borders, L. M., Bingham, P. R., & Riddle, M. C. (1984) · Diabetes Care · doi:10.2337/diacare.7.2.121 · Cited by 32
Research works printed but not linked: 1
- Canilang B, Armstrong D. Subcutaneous abscesses due toMycobacterium fortuitum. Am Rev Resp Dis 1968;97:451–4.
Cited by
7. Diabetes Technology: Standards of Medical Care in Diabetes—2022
American Diabetes Association Professional Practice Committee (2022) · Diabetes Care · doi:10.2337/dc22-s007 · Cited by 358
7. Diabetes Technology: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., Ekhlaspour, L., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s007 · Cited by 348
7. Diabetes Technology: Standards of Care in Diabetes — 2023
ElSayed, N. A., Aleppo, G., Aroda, V. R., Bannuru, R. R., Brown, F. M., Bruemmer, D., Collins, B. S., Hilliard, M. E., Isaacs, D., Johnson, E. L., et al. (2023) · Diabetes Care · doi:10.2337/dc23-s007 · Cited by 301
New insulin delivery recommendations
Frid, A. H., Kreugel, G., Grassi, G., Halimi, S., Hicks, D., Hirsch, L. J., Smith, M. J., Wellhoener, R., Bode, B. W., Hirsch, I. B., et al. (2016) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2016.06.010 · Cited by 286
7. Diabetes Technology: Standards of Care in Diabetes—2024
American Diabetes Association Professional Practice Committee, ElSayed, N. A., Aleppo, G., Bannuru, R. R., Bruemmer, D., Collins, B. S., Ekhlaspour, L., Hilliard, M. E., Johnson, E. L., Khunti, K., et al. (2024) · Diabetes Care · doi:10.2337/dc24-s007 · Cited by 281
7. Diabetes Technology: Standards of Medical Care in Diabetes—2020
American Diabetes Association (2020) · Diabetes Care · doi:10.2337/dc20-s007 · Cited by 250
“reused by the same individual in resourcelimited settings with appropriate storage and cleansing (81).”
Background7. Diabetes Technology: Standards of Medical Care in Diabetes—2021
American Diabetes Association (2021) · Diabetes Care · doi:10.2337/dc21-s007 · Cited by 202
“erally used once but may be reused by the same individual in resource-limited settings with appropriate storage and cleansing (113).”
Background7. Diabetes Technology: Standards of Medical Care in Diabetes—2019
American Diabetes Association (2019) · Diabetes Care · doi:10.2337/dc19-s007 · Cited by 179
“appropriate storage and cleansing (6).”
Financial costs for families of children with Type 1 diabetes in lower‐income countries
Ogle, G. D., Kim, H., Middlehurst, A. C., Silink, M., & Jenkins, A. J. (2015) · Diabetic Medicine · doi:10.1111/dme.12997 · Cited by 59
Indian Injection Technique Study: Population Characteristics and Injection Practices
Kalra, S., Mithal, A., Sahay, R. K., John, M., Unnikrishnan, A., Saboo, B., Ghosh, S. K., Sanyal, D., Hirsch, L. J., Gupta, V., et al. (2017) · Diabetes Therapy · doi:10.1007/s13300-017-0243-x · Cited by 57
“Similar observations have been reported by others for plastic insulin syringe use [44, 45].”
BackgroundThe Injection Technique Factor: What You Don’t Know or Teach Can Make a Difference
Hirsch, L. J., & Strauss, K. W. (2018) · Clinical Diabetes · doi:10.2337/cd18-0076 · Cited by 59
“Bacterial growth was found on reused needles and inflammatory changes (skin redness) were found at injection sites of patients who reused needles (69,70).”
BackgroundZabaleta‐del‐Olmo, E., Vlacho, B., Jódar-Fernández, L., Urpí‐Fernández, A., Lumillo‐Gutiérrez, I., Agudo-Ugena, J., Morros, R., & Violán, C. (2016) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2016.04.010 · Cited by 48
Ademe, M., & Mekonnen, Z. (2014) · Asian Pacific Journal of Tropical Disease · doi:10.1016/s2222-1808(14)60712-x · Cited by 10
“It has been well elucidated that skin lesions and skin irritation are usually associated with bacterial contamination[15,23].”
BackgroundPerinephric Abscess from Insulin Syringe Reuse
Paily, R. (2004) · The American Journal of the Medical Sciences · doi:10.1097/00000441-200401000-00010 · Cited by 8
Risk of cross-infection through shared diabetic devices.
Shalit, P., Brennan, C., Murphy, V. L., & Hooton, T. M. (1990) · PubMed · Cited by 6
Frid, A. H., Hirsch, L. J., & Strauss, K. W. (2019) · IntechOpen eBooks · doi:10.5772/intechopen.76232 · Cited by 2
Subcutaneous Administration of Insulin in Adults: An Integrative Review of the Research
Nicoll, L. H., & Beyea, S. C. (1996) · Worldviews on Evidence-based Nursing presents the archives of Online Journal of Knowledge Synthesis for Nursing · doi:10.1111/j.1524-475x.1996.00019.x · Cited by 2
Infection at Insulin Injection Sites in Diabetic Patients with or without Alcohol Swab
Kshanti, I. A., & Suyono, S. (2011) · Journal Of The Indonesian Medical Association · Cited by 1
Strollo, F., Guarino, G., & Gentile, S. (2025) · Diabetology · doi:10.3390/diabetology6090089
Metadata
- Authors
- Thomas, D. R., Fischer, R. G., Nicholas, W. C., Beghe, C., Hatten, K. W., & Thomas, J. N.
- Affiliations
- University of Mississippi Medical Center (US)
- Venue
- Journal of General Internal Medicine
- Published
- 1989-03
- Volume
- 4
- Issue
- 2
- Pages
- 97-100
- ISSN
- 0884-8734 (ISSN-L)
- 1525-1497
- OpenAlex
- W2039921208
- Cited by
- 19
- References
- 23
- Citations by year
- 2025: 1 · 2024: 1 · 2023: 1 · 2022: 1 · 2021: 1 · 2020: 1 · 2019: 2 · 2018: 2 · 2017: 1 · 2016: 2 · 2015: 1 · 2014: 1
- FWCI
- 0.37
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Journal of General Internal Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Infectious Diseases › Infection Control in Healthcare
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Patient Safety and Medication Errors
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Keywords
- disposable syringes, aseptic technique, diabetes mellitus, insulin injection, medication adherence, needle safety, diabetic outpatients
- MeSH terms
- Asepsis, Costs and Cost Analysis, Diabetes Mellitus, Type 1, Disposable Equipment, Humans, Injections, Insulin, Patient Compliance, Syringes
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.