7. Diabetes Technology: Standards of Care in Diabetes—2025
Open accessAbstract
The American Diabetes Association (ADA) “Standards of Care in Diabetes” includes the ADA’s current clinical practice recommendations and is intended to provide the components of diabetes care, general treatment goals and guidelines, and tools to evaluate quality of care. Members of the ADA Professional Practice Committee, an interprofessional expert committee, are responsible for updating the Standards of Care annually, or more frequently as warranted. For a detailed description of ADA standards, statements, and reports, as well as the evidence-grading system for ADA’s clinical practice recommendations and a full list of Professional Practice Committee members, please refer to Introduction and Methodology. Readers who wish to comment on the Standards of Care are invited to do so at professional.diabetes.org/SOC.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
0 of 284 cited sources checked · 0 supported · 0 flagged
- Premisecitation§ Initiation of Device Use
Interruption of access to CGM is associated with worsening outcomes.
“Interruption of access to CGM is associated with a worsening of outcomes (7,15); therefore, it is important for individuals on CGM to have consistent access to devices.”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [7] Addala, 2020, Uninterrupted continuous glucose monitoring access is associated with a decrease in HbA1c in youth with type 1 diabetes and public insurance, Pediatr Diabetes source
Not checked in the free run.
- cites [15] Aleppo, 2021, The effect of discontinuing continuous glucose monitoring in adults with type 2 diabetes treated with basal insulin, Diabetes Care source
Not checked in the free run.
- Premisecitation§ Education and Training
People with diabetes who receive more education about device use achieve better outcomes.
“Those with more education regarding device use have better outcomes (1,2); therefore, the need for additional education should be periodically assessed, particularly if outcomes are not being met.”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [1] Broos, 2021, Diabetes knowledge and metabolic control in type 1 diabetes starting with continuous glucose monitoring: FUTURE-PEAK, J Clin Endocrinol Metab source
Not checked in the free run.
- cites [2] Yoo, 2022, Effect of structured individualized education on continuous glucose monitoring use in poorly controlled patients with type 1 diabetes: a randomized controlled trial, Diabetes Res Clin Pract source
Not checked in the free run.
- Premisecitation§ People With Diabetes Using Basal Insulin and/or Oral Agents and Noninsulin Injectables
A trial of once-daily BGM with enhanced feedback through messaging found no clinically or statistically significant change in A1C at 1 year.
“A trial of once-daily BGM that included enhanced feedback from people with diabetes through messaging found no clinically or statistically significant change in A1C levels at 1 year (31).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [31] Young, 2017, Glucose self-monitoring in non-insulin-treated patients with type 2 diabetes in primary care settings: a randomized trial, JAMA Intern Med source
Not checked in the free run.
- Interpretationreasoning§ BLOOD GLUCOSE MONITORING
For people using insulin, BGM is an integral component of effective therapy.
“BGM is thus an integral component of effective therapy for individuals using insulin.”
Quote in the paperSubstantial claim - Premisecitation§ People With Diabetes Using Basal Insulin and/or Oral Agents and Noninsulin Injectables
For people with type 2 diabetes taking basal insulin, assessing fasting glucose with BGM to inform dose adjustments to achieve blood glucose goals results in lower A1C levels.
“However, for those taking basal insulin, assessing fasting glucose with BGM to inform dose adjustments to achieve blood glucose goals results in lower A1C levels (30).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [30] Garber, 2014, Treat-to-target trials: uses, interpretation and review of concepts, Diabetes Obes Metab source
Not checked in the free run.
- Premisecitation§ Optimizing Blood Glucose Monitoring Device Use
Among people who check blood glucose at least once daily, many report taking no action when results are high or low.
“Among those who check their blood glucose at least once daily, many report taking no action when results are high or low (25).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [25] Grant, 2015, Patients who self-monitor blood glucose and their unused testing results, Am J Manag Care
Not checked in the free run.
- Premisecitation§ BLOOD GLUCOSE MONITORING
Major clinical trials of insulin-treated people with diabetes included BGM as part of multifactorial interventions that demonstrated intensive glycemic management reduces diabetes complications.
“Major clinical trials of insulin-treated people with diabetes have included BGM as part of multifactorial interventions to demonstrate the benefit of intensive glycemic management on diabetes complications (16).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [16] Nathan, 1993, The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus, N Engl J Med source
Not checked in the free run.
- Premisecitation§ Optimizing Blood Glucose Monitoring Device Use
In people with type 1 diabetes, greater BGM frequency correlates with lower A1C levels.
“In people with type 1 diabetes, there is a correlation between greater BGM frequency and lower A1C levels (24).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [24] Miller, 2013, Evidence of a strong association between frequency of self-monitoring of blood glucose and hemoglobin A1c levels in T1D exchange clinic registry participants, Diabetes Care source
Not checked in the free run.
- Premisecitation§ People With Diabetes Using Basal Insulin and/or Oral Agents and Noninsulin Injectables
In a year-long study of insulin-naive people with diabetes with suboptimal initial glycemic outcomes, a group trained in structured BGM reduced A1C by 0.3% more than the control group.
“In a year-long study of insulin-naive people with diabetes with suboptimal initial glycemic outcomes, a group trained in structured BGM (a paper tool was used at least quarterly to collect and interpret seven-point BGM profiles taken on three consecutive days) reduced their A1C levels by 0.3% more than the control group (32).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [32] Polonsky, 2011, Structured self-monitoring of blood glucose significantly reduces A1C levels in poorly controlled, noninsulin-treated type 2 diabetes: results from the Structured Testing Program study, Diabetes Care source
Not checked in the free run.
- Premisecitation§ Glucose Meter Inaccuracy
Several physiologic and pharmacologic factors interfere with glucose readings measured by personal or professional blood glucose meters in various inpatient settings.
“There are several physiologic and pharmacologic factors that interfere with glucose readings measured with either personal blood glucose meters or professional blood glucose meters used in various inpatient settings (neonatal intensive care unit, hospital wards, and intensive care unit) (37).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [37] Sacks, 2023, Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus, Diabetes Care source
Not checked in the free run.
- Premisecitation§ Glucose Meter Inaccuracy
Because the reaction is sensitive to temperature, all glucose monitors have an acceptable temperature range.
“Because the reaction is sensitive to temperature, all monitors have an acceptable temperature range (37).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [37] Sacks, 2023, Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus, Diabetes Care source
Not checked in the free run.
- Premisecitation§ Meter Standards
There is substantial variation in the accuracy of widely used BGM systems.
“There is substantial variation in the accuracy of widely used BGM systems (17,18).”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [17] King, 2018, A review of blood glucose monitor accuracy, Diabetes Technol Ther source
Not checked in the free run.
- cites [18] Brazg, 2013, Performance variability of seven commonly used self-monitoring of blood glucose systems: clinical considerations for patients and providers, J Diabetes Sci Technol source
Not checked in the free run.
- Premisecitation§ Meter Standards
In a subsequent analysis with updated glucose meters, 14 of 18 glucose meters met the minimum accuracy requirements.
“In a subsequent analysis with updated glucose meters, 14 of 18 glucose meters met the minimum accuracy requirements (20).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [20] Pleus, 2019, Documentation of skin-related issues associated with continuous glucose monitoring use in the scientific literature, Diabetes Technol Ther source
Not checked in the free run.
- Interpretationnone given§ People With Diabetes Using Basal Insulin and/or Oral Agents and Noninsulin Injectables
The evidence is insufficient regarding when to prescribe BGM and how often monitoring is needed for insulin-treated people with diabetes who do not use intensive insulin therapy.
“The evidence is insufficient regarding when to prescribe BGM and how often monitoring is needed for insulin-treated people with diabetes who do not use intensive insulin therapy, such as those with type 2 diabetes taking basal insulin with or without oral agents and/or noninsulin injectables.”
Quote in the paperSubstantial claim - Premisecitation§ Glucose Meter Inaccuracy
Glucose dehydrogenase-based monitors are generally not sensitive to oxygen.
“Glucose dehydrogenase-based monitors are generally not sensitive to oxygen.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [37] Sacks, 2023, Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus, Diabetes Care source
Not checked in the free run.
- Premisecitation§ Meter Standards
Certain meter system characteristics, such as less painful lancing devices and the ability to reapply blood to a strip with an insufficient initial sample, may benefit people with diabetes and make BGM less burdensome.
“Certain meter system characteristics, such as the use of lancing devices that are less painful (21) and the ability to reapply blood to a strip with an insufficient initial sample, or meters with integrated speech that can read aloud glucose levels for visually impaired individuals (22), may also be beneficial to people with diabetes (23) and may make BGM less burdensome to perform.”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [21] Grady, 2021, Clinical evaluation of a new, lower pain, one touch lancing device for people with diabetes: virtually pain-free testing and improved comfort compared to current lancing systems, J Diabetes Sci Technol source
Not checked in the free run.
- cites [22] Burton, 2012, Blood glucose meters and accessibility to blind and visually impaired people, J Diabetes Sci Technol source
Not checked in the free run.
- cites [23] Harrison, 2020, Accuracy of a blood glucose monitoring system that recognizes insufficient sample blood volume and allows application of more blood to the same test strip, Expert Rev Med Devices source
Not checked in the free run.
- Premisecitation§ CONTINUOUS GLUCOSE MONITORING DEVICES
The frequency of scanning with isCGM devices is correlated with improved outcomes.
“The frequency of scanning with isCGM devices is also correlated with improved outcomes (40-43).”
Quote in the paperSubstantial claim0 of 4 sources checked- cites [40] Hansen, 2022, The frequency of intermittently scanned glucose and diurnal variation of glycemic metrics, J Diabetes Sci Technol source
Not checked in the free run.
- cites [41] Urakami, 2022, Frequent scanning using flash glucose monitoring contributes to better glycemic control in children and adolescents with type 1 diabetes, J Diabetes Investig source
Not checked in the free run.
- cites [42] Lameijer, 2021, Flash glucose monitoring in the Netherlands: increased monitoring frequency is associated with improvement of glycemic parameters, Diabetes Res Clin Pract source
Not checked in the free run.
- cites [43] Hohendorff, 2021, Intermittently scanned continuous glucose monitoring data of polish patients from real-life conditions: more scanning and better glycemic control compared to worldwide data, Diabetes Technol Ther source
Not checked in the free run.
- Premisecitation§ Meter Standards
In one analysis, 6 of the top 18 best-selling glucose meters met the accuracy standard.
“In one analysis, 6 of the top 18 best-selling glucose meters met the accuracy standard (19).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [19] Klonoff, 2018, Investigation of the accuracy of 18 marketed blood glucose monitors, Diabetes Care source
Not checked in the free run.
- Premisecitation§ Glucose Meter Inaccuracy
Currently available glucose monitors use an enzymatic reaction linked to an electrochemical reaction, either glucose oxidase or glucose dehydrogenase.
“Currently available glucose monitors use an enzymatic reaction linked to an electrochemical reaction, either glucose oxidase or glucose dehydrogenase (37).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [37] Sacks, 2023, Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus, Diabetes Care source
Not checked in the free run.
- Premisecitation§ CONTINUOUS GLUCOSE MONITORING DEVICES
For people with type 1 diabetes using CGM, frequency of sensor use is an important predictor of A1C lowering across all age groups.
“For people with type 1 diabetes using CGM, frequency of sensor use is an important predictor of A1C lowering for all age-groups (38,39).”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [38] Tamborlane, 2008, Continuous glucose monitoring and intensive treatment of type 1 diabetes, N Engl J Med source
Not checked in the free run.
- cites [39] Tumminia, 2015, Efficacy of real-time continuous glucose monitoring on glycaemic control and glucose variability in type 1 diabetic patients treated with either insulin pumps or multiple insulin injection therapy: a randomized controlled crossover trial, Diabetes Metab Res Rev source
Not checked in the free run.
- Premisecitation§ Data From Randomized Controlled Trials
Multiple RCTs using rtCGM devices have largely shown positive results in reducing A1C levels and/or hypoglycemia episodes when participants regularly wore the devices.
“Multiple randomized controlled trials (RCTs) have been performed using rtCGM devices, and the results have largely been positive in terms of reducing A1C levels and/or episodes of hypoglycemia if participants regularly wore the devices (38)(39)(40)(41)(48)(49)(50)(51).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites (38)(39)(40)(41)(48)(49)(50)(51)
Not checked in the free run.
- Premisecitation§ Data From Randomized Controlled Trials
In young children with type 1 diabetes, rtCGM use reduced hypoglycemia.
“Data in children show that rtCGM use in young children with type 1 diabetes reduced hypoglycemia”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [38] Tamborlane, 2008, Continuous glucose monitoring and intensive treatment of type 1 diabetes, N Engl J Med source
Not checked in the free run.
- cites [49] Strategies to Enhance New CGM Use in Early Childhood (SENCE) Study Group, 2021, A randomized clinical trial assessing continuous glucose monitoring (CGM) use with standardized education with or without a family behavioral intervention compared with fingerstick blood glucose monitoring in very young children with type 1 diabetes, Diabetes Care source
Not checked in the free run.
- cites [58] Van Name, 2023, Long-term continuous glucose monitor use in very young children with type 1 diabetes: one-year results from the SENCE study, J Diabetes Sci Technol source
Not checked in the free run.
- Premisecitation§ Data From Randomized Controlled Trials
A1C reduction was seen in adolescents and young adults with type 1 diabetes using rtCGM.
“Similarly, A1C level reduction was seen in adolescents and young adults with type 1 diabetes using rtCGM (48).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [48] Laffel, 2020, Effect of continuous glucose monitoring on glycemic control in adolescents and young adults with type 1 diabetes: a randomized clinical trial, JAMA source
Not checked in the free run.
- Premisecitation§ CONTINUOUS GLUCOSE MONITORING DEVICES
CGM systems are generally nonadjunctive, meaning they do not require BGM confirmation for treatment decisions like insulin dosing or treating hypoglycemia, except in certain clinical situations.
“CGM systems are generally nonadjunctive, meaning they do not require BGM confirmation for treatment decisions like insulin dosing or treating hypoglycemia, except in certain clinical situations (see BLOOD GLUCOSE MONITORING, above) (44-46).”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [44] Aleppo, 2017, REPLACE-BG: a randomized trial comparing continuous glucose monitoring with and without routine blood glucose monitoring in adults with well-controlled type 1 diabetes, Diabetes Care source
Not checked in the free run.
- cites [45] Friedman, 2023, Use of continuous glucose monitors to manage type 1 diabetes mellitus: progress, challenges, and recommendations, Pharmgenomics Pers Med
Not checked in the free run.
- cites [46] Klonoff, 2024, Importance of FDA-integrated continuous glucose monitors to ensure accuracy of continuous glucose monitoring, J Diabetes Sci Technol source
Not checked in the free run.
- Premisecitation§ Data From Randomized Controlled Trials
A randomized trial of adults with type 1 diabetes showed that isCGM with optional alerts and alarms reduced A1C compared with BGM.
“A randomized trial of adults with type 1 diabetes showed that the use of isCGM with optional alerts and alarms resulted in reduction of A1C levels compared with BGM use ( 9).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [9] Leelarathna, 2022, Intermittently scanned continuous glucose monitoring for type 1 diabetes, N Engl J Med source
Not checked in the free run.
- Premisecitation§ Observational and Real-world Studies
In adults with type 1 diabetes who wear intermittently scanned CGM, A1C levels improve.
“In individuals with type 1 diabetes wearing isCGM devices, studies have shown improvement in A1C levels (41,77)”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [41] Urakami, 2022, Frequent scanning using flash glucose monitoring contributes to better glycemic control in children and adolescents with type 1 diabetes, J Diabetes Investig source
Not checked in the free run.
- cites [77] Tyndall, 2019, Marked improvement in HbA1c following commencement of flash glucose monitoring in people with type 1 diabetes, Diabetologia source
Not checked in the free run.
- Interpretationreasoning§ Data From Randomized Controlled Trials
The improvements in type 2 diabetes from rtCGM have largely occurred without changes in insulin doses or other diabetes medications.
“The improvements in type 2 diabetes have largely occurred without changes in insulin doses or other diabetes medications.”
Quote in the paperNot a substantial claim - Premisecitation§ Data From Randomized Controlled Trials
One study in adults with type 1 diabetes met its primary outcome of a reduction in hypoglycemia rates.
“One study was performed in adults with type 1 diabetes and met its primary outcome of a reduction in rates of hypoglycemia (68).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [68] Bolinder, 2016, Novel glucose-sensing technology and hypoglycaemia in type 1 diabetes: a multicentre, non-masked, randomised controlled trial, Lancet source
Not checked in the free run.
- Premisecitation§ Real-time Continuous Glucose Monitoring Compared With Intermittently Scanned Continuous Glucose Monitoring
In adults with type 1 diabetes, real-time CGM with predictive alerts/alarms shows greater benefit than intermittently scanned CGM without predictive alerts/alarms for reducing time spent in hypoglycemia in two randomized controlled trials.
“In two of the studies, the primary outcome was a reduction in time spent in hypoglycemia, and rtCGM showed greater benefits compared with isCGM (89,90).”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [89] Reddy, 2018, A randomized controlled pilot study of continuous glucose monitoring and flash glucose monitoring in people with type 1 diabetes and impaired awareness of hypoglycaemia, Diabet Med source
Not checked in the free run.
- cites [90] Hásková, 2020, Real-time CGM is superior to flash glucose monitoring for glucose control in type 1 diabetes: the CORRIDA randomized controlled trial, Diabetes Care source
Not checked in the free run.
- Premisecitation§ Observational and Real-world Studies
In adults with type 1 diabetes who wear intermittently scanned CGM, hypoglycemia improves.
“and hypoglycemia (41,43,75,78,79).”
Quote in the paperSubstantial claim0 of 5 sources checked- cites [41] Urakami, 2022, Frequent scanning using flash glucose monitoring contributes to better glycemic control in children and adolescents with type 1 diabetes, J Diabetes Investig source
Not checked in the free run.
- cites [43] Hohendorff, 2021, Intermittently scanned continuous glucose monitoring data of polish patients from real-life conditions: more scanning and better glycemic control compared to worldwide data, Diabetes Technol Ther source
Not checked in the free run.
- cites [75] Deshmukh, 2020, Effect of flash glucose monitoring on glycemic control, hypoglycemia, diabetes-related distress, and resource utilization in the Association of British Clinical Diabetologists (ABCD) nationwide audit, Diabetes Care source
Not checked in the free run.
- cites [78] Nathanson, 2021, Effect of flash glucose monitoring in adults with type 1 diabetes: a nationwide, longitudinal observational study of 14,372 flash users compared with 7691 glucose sensor naive controls, Diabetologia source
Not checked in the free run.
- cites [79] Charleer, 2020, Quality of life and glucose control after 1 year of nationwide reimbursement of intermittently scanned continuous glucose monitoring in adults living with type 1 diabetes (FUTURE): a prospective observational real-world cohort study, Diabetes Care source
Not checked in the free run.
- Premisecitation§ Observational and Real-world Studies
In adults with type 2 diabetes treated with basal insulin or noninsulin therapy, intermittently scanned CGM improves A1C levels.
“Furthermore, retrospective observational data in adults with type 2 diabetes treated with either basal insulin or noninsulin therapy have shown an improvement in A1C levels (85).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [85] Wright, 2021, Use of flash continuous glucose monitoring is associated with A1C reduction in people with type 2 diabetes treated with basal insulin or noninsulin therapy, Diabetes Spectr source
Not checked in the free run.
- Premisecitation§ Observational and Real-world Studies
The reductions in acute diabetes complications with intermittently scanned CGM persist even after 2 years of CGM initiation.
“with persistent effects observed even after 2 years of CGM initiation (81).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [81] Riveline, 2022, Reduced rate of acute diabetes events with flash glucose monitoring is sustained for 2 years after initiation: extended outcomes from the RELIEF study, Diabetes Technol Ther source
Not checked in the free run.
- Premisecitation§ Observational and Real-world Studies
In adults with type 2 diabetes treated with multiple daily injections, 12 weeks of intermittently scanned CGM use significantly reduces A1C and hypoglycemia.
“Prospective observational as well as retrospective studies in adults with type 2 diabetes treated with MDI showed significant reduction of A1C and hypoglycemia (83) after 12 weeks of isCGM use”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [83] Al Hayek, 2021, The impact of flash glucose monitoring on markers of glycaemic control and patient satisfaction in type 2 diabetes, Cureus
Not checked in the free run.
- Premisecitation§ Real-time Continuous Glucose Monitoring Device Use in Pregnancy
In pregnancies evaluated with real-time CGM and intermittently scanned CGM, lower mean glucose, lower SD, and higher percentage of time in range are associated with lower risks of large-for-gestational-age births and other adverse neonatal outcomes.
“An observational cohort study that evaluated the glycemic variables reported using rtCGM and isCGM found that lower mean glucose, lower SD, and higher percentage of TIR were associated with lower risks of large-for-gestational-age births and other adverse neonatal outcomes ( 104).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [104] Kristensen, 2019, Continuous glucose monitoring in pregnant women with type 1 diabetes: an observational cohort study of 186 pregnancies, Diabetologia source
Not checked in the free run.
- Premisecitation§ Use of Professional Continuous Glucose Monitoring and Intermittent Use of Continuous Glucose Monitoring
In randomized controlled trials, people with type 2 diabetes not on intensive insulin therapy who used CGM intermittently compared with blood glucose monitoring had early and late improvements in A1C levels.
“In these RCTs, people with type 2 diabetes not on intensive insulin therapy used CGM intermittently compared with those randomized to BGM.Both early (60) and late improvements in A1C levels were found (60,73).”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [60] Ehrhardt, 2011, The effect of real-time continuous glucose monitoring on glycemic control in patients with type 2 diabetes mellitus, J Diabetes Sci Technol source
Not checked in the free run.
- cites [73] Wada, 2020, Flash glucose monitoring helps achieve better glycemic control than conventional self-monitoring of blood glucose in non-insulin-treated type 2 diabetes: a randomized controlled trial, BMJ Open Diabetes Res Care source
Not checked in the free run.
- Premisecitation§ Side Effects of Continuous Glucose Monitoring Devices
Contact dermatitis, both irritant and allergic, has been reported with all devices that attach to the skin.
“Contact dermatitis (both irritant and allergic) has been reported with all devices that attach to the skin (20,117,118).”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [20] Pleus, 2019, Documentation of skin-related issues associated with continuous glucose monitoring use in the scientific literature, Diabetes Technol Ther source
Not checked in the free run.
- cites [117] Herman, 2020, Adverse cutaneous reaction to diabetic glucose sensors and insulin pumps: irritant contact dermatitis or allergic contact dermatitis?, Contact Dermatitis source
Not checked in the free run.
- cites [118] Rigo, 2021, Cutaneous reactions to continuous glucose monitoring and continuous subcutaneous insulin infusion devices in type 1 diabetes mellitus, J Diabetes Sci Technol source
Not checked in the free run.
- Premisecitation§ Real-time Continuous Glucose Monitoring Compared With Intermittently Scanned Continuous Glucose Monitoring
In adults with type 1 diabetes, real-time CGM shows greater benefit than intermittently scanned CGM for improving time in range in one randomized controlled trial.
“In the other study, the primary outcome was improved TIR, and rtCGM also showed greater benefits compared with isCGM (84).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [84] Visser, 2021, Comparing real-time and intermittently scanned continuous glucose monitoring in adults with type 1 diabetes (ALERTT1): a 6-month, prospective, multicentre, randomised controlled trial, Lancet source
Not checked in the free run.
- Interpretationcitation§ Real-time Continuous Glucose Monitoring Device Use in Pregnancy
At this time, data are insufficient to recommend CGM for all pregnant people with type 2 diabetes or gestational diabetes mellitus.
“At this time, data are insufficient to recommend the use of CGM in all pregnant people with type 2 diabetes or GDM (109,110).”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [109] García-Moreno, 2022, Efficacy of continuous glucose monitoring on maternal and neonatal outcomes in gestational diabetes mellitus: a systematic review and meta-analysis of randomized clinical trials, Diabet Med source
Not checked in the free run.
- cites [110] Wyckoff, 2021, Time in range in pregnancy: is there a role?, Diabetes Spectr source
Not checked in the free run.
- Premisecitation§ Real-time Continuous Glucose Monitoring Device Use in Pregnancy
CGM indication is now expanded to include pregnancy for Dexcom G7, FreeStyle Libre 2, and FreeStyle Libre 3.
“CGM indication is now expanded to include pregnancy for Dexcom G7, FreeStyle Libre 2, and FreeStyle Libre 3, which will enhance care in this population (101,102).”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [101] Akturk, 2024, Recent advances in diabetes technology and activities of the American Diabetes Association Diabetes Technology Interest Group, Clin Diabetes source
Not checked in the free run.
- cites [102] Dexcom, Inc . Dexcom G7 Continuous Glucose Monitoring System. Integrated Continuous Glucose Monitoring System, Factory Calibrated. Accessed 14 August 2024. Available from https://fda.report/PMN/K213919
Not checked in the free run.
- Premisecitation§ INSULIN DELIVERY Insulin Syringes and Pens
Injecting insulin with a syringe or pen is the insulin delivery method used by most people with diabetes.
“Injecting insulin with a syringe or pen (136-147) is the insulin delivery method used by most people with diabetes (142,148), although inhaled insulin is also available.”
Quote in the paperNot a substantial claim0 of 10 sources checked- cites [136] Piras de Oliveira, 2021, Patient perspectives on the use of half-unit insulin pens by people with type 1 diabetes: a cross-sectional observational study, Curr Med Res Opin source
Not checked in the free run.
- cites [137] Machry, 2021, Pens versus syringes to deliver insulin among elderly patients with type 2 diabetes: a randomized controlled clinical trial, Diabetol Metab Syndr source
Not checked in the free run.
- cites [138] Korytkowski, 2003, A multicenter, randomized, open-label, comparative, two-period crossover trial of preference, efficacy, and safety profiles of a prefilled, disposable pen and conventional vial/syringe for insulin injection in patients with type 1 or 2 diabetes mellitus, Clin Ther source
Not checked in the free run.
- cites [139] Asche, 2010, Health economics and compliance of vials/syringes versus pen devices: a review of the evidence, Diabetes Technol Ther source
Not checked in the free run.
- cites [140] Singh, 2018, A comparison of insulin pen devices and disposable plastic syringes–simplicity, safety, convenience and cost differences, Eur Endocrinol
Not checked in the free run.
- cites [141] Frid, 2016, New insulin delivery recommendations, Mayo Clin Proc source
Not checked in the free run.
- cites [142] Lasalvia, 2016, Pen devices for insulin self-administration compared with needle and vial: systematic review of the literature and meta-analysis, J Diabetes Sci Technol source
Not checked in the free run.
- cites [143] Slabaugh, 2015, Characteristics relating to adherence and persistence to basal insulin regimens among elderly insulin-naïve patients with type 2 diabetes: pre-filled pens versus vials/syringes, Adv Ther source
Not checked in the free run.
- cites [144] Chandran, 2015, Adherence to insulin pen therapy is associated with reduction in healthcare costs among patients with type 2 diabetes mellitus, Am Health Drug Benefits
Not checked in the free run.
- cites [145] Ahmann, 2014, Comparing patient preferences and healthcare provider recommendations with the pen versus vial-and-syringe insulin delivery in patients with type 2 diabetes, Diabetes Technol Ther source
Not checked in the free run.
- Premisecitation§ Side Effects of Continuous Glucose Monitoring Devices
In some cases, contact dermatitis has been linked to isobornyl acrylate, a skin sensitizer that can cause an additional spreading allergic reaction.
“In some cases, this has been linked to the presence of isobornyl acrylate, a skin sensitizer that can cause an additional spreading allergic reaction (119-121).”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [119] Kamann, 2018, Further evidence of severe allergic contact dermatitis from isobornyl acrylate while using a continuous glucose monitoring system, J Diabetes Sci Technol source
Not checked in the free run.
- cites [120] Aerts, 2017, FreeStyle Libre: contact irritation versus contact allergy, Lancet source
Not checked in the free run.
- cites [121] Herman, 2017, Allergic contact dermatitis caused by isobornyl acrylate in Freestyle Libre, a newly introduced glucose sensor, Contact Dermatitis source
Not checked in the free run.
- Premisecitation§ Substances and Factors Affecting Continuous Glucose Monitoring Accuracy
Hydroxyurea is one of the most recently identified interfering substances that cause a temporary increase in sensor glucose values discrepant from actual glucose values.
“Hydroxyurea, used for myeloproliferative disorders and hematologic conditions, is one of the most recently identified interfering substances that cause a temporary increase in sensor glucose values discrepant from actual glucose values (129-134).”
Quote in the paperNot a substantial claim0 of 6 sources checked- cites [129] Heinemann, 2022, Interferences with CGM systems: practical relevance?, J Diabetes Sci Technol source
Not checked in the free run.
- cites [130] Tellez, 2021, Inaccurate glucose sensor values after hydroxyurea administration, Diabetes Technol Ther source
Not checked in the free run.
- cites [131] Szmuilowicz, 2021, Interferent effect of hydroxyurea on continuous glucose monitoring, Diabetes Care source
Not checked in the free run.
- cites [132] Pfützner, 2022, Laboratory protocol and pilot results for dynamic interference testing of continuous glucose monitoring sensors, J Diabetes Sci Technol source
Not checked in the free run.
- cites [133] Lorenz, 2018, Interference assessment of various endogenous and exogenous substances on the performance of the Eversense long-term implantable continuous glucose monitoring system, Diabetes Technol Ther source
Not checked in the free run.
- cites [134] Denham, 2021, Effect of repeated doses of acetaminophen on a continuous glucose monitoring system with permselective membrane, J Diabetes Sci Technol source
Not checked in the free run.
- Premisecitation§ Substances and Factors Affecting Continuous Glucose Monitoring Accuracy
Mannitol and sorbitol, when administered intravenously or as a component of peritoneal dialysis solution, may increase blood mannitol or sorbitol concentrations and cause falsely elevated readings of sensor glucose.
“Similarly, substances such as mannitol and sorbitol, when administered intravenously or as a component of peritoneal dialysis solution, may increase blood mannitol or sorbitol concentrations and cause falsely elevated readings of sensor glucose (135).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [135] U.S. FDA . Summary of safety and effectiveness data (SSED). Continuous glucose monitor (CGM), implanted, adjunctive use 2018. Accessed 14 August 2024. Available from https://www.accessdata.fda.gov/cdrh_docs/pdf16/P160048B.pdf
Not checked in the free run.
- Premisecitation§ INSULIN PUMPS AND AUTOMATED INSULIN DELIVERY SYSTEMS,
Insulin pens may allow people with vision impairment or dexterity issues to dose insulin accurately.
“Insulin pens may allow people with vision impairment or dexterity issues to dose insulin accurately (149-151), and insulin injection aids are also available to help with these issues.”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [149] Pfützner, 2012, Comparison of patient preference for two insulin injection pen devices in relation to patient dexterity skills, J Diabetes Sci Technol source
Not checked in the free run.
- cites [150] Reinauer, 1990, Insulin pens in elderly diabetic patients, Diabetes Care source
Not checked in the free run.
- cites [151] Thomas, 1989, Disposable insulin syringe reuse and aseptic practices in diabetic patients, J Gen Intern Med source
Not checked in the free run.
- Premisecitation§ Insulin Pumps
Pump therapy can be successfully started at the time of diagnosis.
“Pump therapy can be successfully started at the time of diagnosis (168).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [168] Berghaeuser, 2008, Continuous subcutaneous insulin infusion in toddlers starting at diagnosis of type 1 diabetes mellitus. A multicenter analysis of 104 patients from 63 centres in Germany and Austria, Pediatr Diabetes source
Not checked in the free run.
- Premisecitation§ INSULIN PUMPS AND AUTOMATED INSULIN DELIVERY SYSTEMS,
A systematic review of connected insulin pens or pen caps showed improvement of glucose outcomes whether as A1C reduction, time in range increase, or hypoglycemia reduction.
“A systematic review of connected insulin pens or pen caps showed improvement of glucose outcomes whether as A1C reduction, TIR increase, or hypoglycemia reduction (155).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [155] Cranston, 2023, Clinical, economic, and patient-reported benefits of connected insulin pen systems: a systematic literature review, Adv Ther source
Not checked in the free run.
- Premisecitation§ INSULIN PUMPS AND AUTOMATED INSULIN DELIVERY SYSTEMS,
In a recent randomized clinical trial, technosphere inhaled insulin showed lower postprandial hyperglycemia than subcutaneous rapid-acting analog insulin.
“In a recent randomized clinical trial, the use of technosphere inhaled insulin showed lower postprandial hyperglycemia than subcutaneous rapid-acting analog insulin (152).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [152] Hirsch, 2024, A randomized comparison of postprandial glucose excursion using inhaled insulin versus rapid-acting analog insulin in adults with type 1 diabetes using multiple daily injections of insulin or automated insulin delivery, Diabetes Care source
Not checked in the free run.
- Premisecitation§ Insulin Pumps
There are no data to suggest that measurement of C-peptide levels or antibodies predicts success with insulin pump therapy.
“There are no data to suggest that measurement of C-peptide levels or antibodies predicts success with insulin pump therapy (170,171).”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [170] Gill, 2018, C-peptide and beta-cell autoantibody testing prior to initiating continuous subcutaneous insulin infusion pump therapy did not improve utilization or medical costs among older adults with diabetes mellitus, Endocr Pract source
Not checked in the free run.
- cites [171] Vigersky, 2018, Improved HBa1c, total daily insulin dose, and treatment satisfaction with insulin pump therapy compared to multiple daily insulin injections in patients with type 2 diabetes irrespective of baseline c-peptide levels, Endocr Pract source
Not checked in the free run.
- Premisecitation§ Insulin Pumps
Complications of the pump can be caused by issues with infusion sets such as dislodgement and occlusion, which put individuals at risk for ketosis and diabetic ketoacidosis.
“Complications of the pump can be caused by issues with infusion sets (dislodgement and occlusion), which put individuals at risk for ketosis and DKA and thus must be recognized and managed early (172).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [172] Wheeler, 2014, Insulin pump-associated adverse events in children and adolescents–a prospective study, Diabetes Technol Ther source
Not checked in the free run.
- Premisecitation§ Data From Pivotal Trials
Across pivotal trials, AID systems in people aged 2 years and older, including older adults, were superior to standard insulin delivery/manual mode or SAP/usual care.
“all AID system pivotal trials that examined individuals 2 years old or older, including older adults, have consistently demonstrated superiority to either standard insulin delivery (or manual mode for the single-arm studies) or SAP and/or usual care (for the randomized trials)”
Quote in the paperSubstantial claim0 of 10 sources checked- cites [207] Kaur, 2019, Efficacy of hybrid closed-loop system in adults with type 1 diabetes and gastroparesis, Diabetes Technol Ther source
Not checked in the free run.
- cites [208] Brown, 2019, Six-month randomized, multicenter trial of closed-loop control in type 1 diabetes, N Engl J Med source
Not checked in the free run.
- cites [209] Sherr, 2020, Safety and performance of the Omnipod hybrid closed-loop system in adults, adolescents, and children with type 1 diabetes over 5 days under free-living conditions, Diabetes Technol Ther source
Not checked in the free run.
- cites [210] Lal, 2019, One year clinical experience of the first commercial hybrid closed-loop system, Diabetes Care source
Not checked in the free run.
- cites [211] Kovatchev, 2020, Randomized controlled trial of mobile closed-loop control, Diabetes Care source
Not checked in the free run.
- cites [212] Beck, 2022, A multicenter randomized trial evaluating fast-acting insulin aspart in the bionic pancreas in adults with type 1 diabetes, Diabetes Technol Ther source
Not checked in the free run.
- cites [213] Messer, 2022, Positive impact of the bionic pancreas on diabetes control in youth 6-17 years old with type 1 diabetes: a multicenter randomized trial, Diabetes Technol Ther source
Not checked in the free run.
- cites [214] Castellanos, 2023, The insulin-only bionic pancreas improves glycemic control in non-Hispanic White and minority adults and children with type 1 diabetes, Diabetes Care source
Not checked in the free run.
- cites [215] Russell, 2022, Multicenter, randomized trial of a bionic pancreas in type 1 diabetes, N Engl J Med source
Not checked in the free run.
- cites [216] Kruger, 2022, A multicenter randomized trial evaluating the insulin-only configuration of the bionic pancreas in adults with type 1 diabetes, Diabetes Technol Ther source
Not checked in the free run.
- Premisecitation§ Insulin Pumps in Youth
The safety of insulin pumps in youth has been established for over 15 years.
“The safety of insulin pumps in youth has been established for over 15 years (176).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [176] Plotnick, 2003, Safety and effectiveness of insulin pump therapy in children and adolescents with type 1 diabetes, Diabetes Care source
Not checked in the free run.
- Premisecitation§ Sensor-Augmented Pumps
Predictive low-glucose suspend systems have been shown to reduce time spent with glucose <70 mg/dL without rebound hyperglycemia during a 6-week randomized crossover trial.
“Predictive lowglucose suspend systems have been shown to reduce time spent with glucose <70 mg/dL without rebound hyperglycemia during a 6-week randomized crossover trial (190).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [190] Forlenza, 2018, Predictive low-glucose suspend reduces hypoglycemia in adults, adolescents, and children with type 1 diabetes in an at-home randomized crossover study: results of the PROLOG trial, Diabetes Care source
Not checked in the free run.
- Study design and conductcitation§ Data From Pivotal Trials
All FDA-approved AID systems have been evaluated for safety and efficacy in pivotal trials involving children and adults with type 1 diabetes.
“All currently FDA-approved AID systems were tested for safety and efficacy in their pivotal trials in children and adults with type 1 diabetes (194)(195)(196)(197)(198)(199)(200)(201)(202)(203)(204)(205)(206).”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [194] Bergenstal, 2016, Safety of a hybrid closed-loop insulin delivery system in patients with type 1 diabetes, JAMA source
Not checked in the free run.
- cites [195] Garg, 2017, Glucose outcomes with the in-home use of a hybrid closed-loop insulin delivery system in adolescents and adults with type 1 diabetes, Diabetes Technol Ther source
Not checked in the free run.
- cites [196] Tauschmann, 2018, Closed-loop insulin delivery in suboptimally controlled type 1 diabetes: a multicentre, 12-week randomised trial, Lancet source
Not checked in the free run.
- Interpretationnone given§ Insulin Pumps in Youth
Because of a paucity of data in adolescents and youth with type 2 diabetes, there is insufficient evidence to make recommendations.
“Because of a paucity of data in adolescents and youth with type 2 diabetes, there is insufficient evidence to make recommendations.”
Quote in the paperSubstantial claim - Premisecitation§ Insulin Pumps in Youth
Randomized controlled trials comparing insulin pumps and multiple daily injections with rapid-acting insulin analogs demonstrated a modest improvement in A1C levels in participants on insulin pump therapy.
“However, RCTs that compared insulin pumps and MDI with rapidacting insulin analogs demonstrated a modest improvement in A1C levels in participants on insulin pump therapy (178,179).”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [178] Doyle, 2004, A randomized, prospective trial comparing the efficacy of continuous subcutaneous insulin infusion with multiple daily injections using insulin glargine, Diabetes Care source
Not checked in the free run.
- cites [179] Alemzadeh, 2004, Beneficial effects of continuous subcutaneous insulin infusion and flexible multiple daily insulin regimen using insulin glargine in type 1 diabetes, Pediatrics source
Not checked in the free run.
- Premisecitation§ Insulin Pumps in Youth
Treatment satisfaction and quality-of-life measures improved on insulin pump therapy compared with multiple daily injections.
“In addition, treatment satisfaction and quality-oflife measures improved on insulin pump therapy compared with MDI (187).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [187] Opipari-Arrigan, 2007, Continuous subcutaneous insulin infusion benefits quality of life in preschool-age children with type 1 diabetes mellitus, Pediatr Diabetes source
Not checked in the free run.
- Premisecitation§ Data From Pivotal Trials
AID use in pivotal trials consistently increased TIR, especially overnight.
“with consistent improvement in A1C, increase in TIR, especially overnight, as well as reduction of time spent in hypoglycemia (207-219).”
Quote in the paperSubstantial claim0 of 10 sources checked- cites [207] Kaur, 2019, Efficacy of hybrid closed-loop system in adults with type 1 diabetes and gastroparesis, Diabetes Technol Ther source
Not checked in the free run.
- cites [208] Brown, 2019, Six-month randomized, multicenter trial of closed-loop control in type 1 diabetes, N Engl J Med source
Not checked in the free run.
- cites [209] Sherr, 2020, Safety and performance of the Omnipod hybrid closed-loop system in adults, adolescents, and children with type 1 diabetes over 5 days under free-living conditions, Diabetes Technol Ther source
Not checked in the free run.
- cites [210] Lal, 2019, One year clinical experience of the first commercial hybrid closed-loop system, Diabetes Care source
Not checked in the free run.
- cites [211] Kovatchev, 2020, Randomized controlled trial of mobile closed-loop control, Diabetes Care source
Not checked in the free run.
- cites [212] Beck, 2022, A multicenter randomized trial evaluating fast-acting insulin aspart in the bionic pancreas in adults with type 1 diabetes, Diabetes Technol Ther source
Not checked in the free run.
- cites [213] Messer, 2022, Positive impact of the bionic pancreas on diabetes control in youth 6-17 years old with type 1 diabetes: a multicenter randomized trial, Diabetes Technol Ther source
Not checked in the free run.
- cites [214] Castellanos, 2023, The insulin-only bionic pancreas improves glycemic control in non-Hispanic White and minority adults and children with type 1 diabetes, Diabetes Care source
Not checked in the free run.
- cites [215] Russell, 2022, Multicenter, randomized trial of a bionic pancreas in type 1 diabetes, N Engl J Med source
Not checked in the free run.
- cites [216] Kruger, 2022, A multicenter randomized trial evaluating the insulin-only configuration of the bionic pancreas in adults with type 1 diabetes, Diabetes Technol Ther source
Not checked in the free run.
- Premisecitation§ Data From Pivotal Trials
AID use in pivotal trials consistently improved A1C.
“with consistent improvement in A1C, increase in TIR, especially overnight, as well as reduction of time spent in hypoglycemia (207-219).”
Quote in the paperSubstantial claim0 of 10 sources checked- cites [207] Kaur, 2019, Efficacy of hybrid closed-loop system in adults with type 1 diabetes and gastroparesis, Diabetes Technol Ther source
Not checked in the free run.
- cites [208] Brown, 2019, Six-month randomized, multicenter trial of closed-loop control in type 1 diabetes, N Engl J Med source
Not checked in the free run.
- cites [209] Sherr, 2020, Safety and performance of the Omnipod hybrid closed-loop system in adults, adolescents, and children with type 1 diabetes over 5 days under free-living conditions, Diabetes Technol Ther source
Not checked in the free run.
- cites [210] Lal, 2019, One year clinical experience of the first commercial hybrid closed-loop system, Diabetes Care source
Not checked in the free run.
- cites [211] Kovatchev, 2020, Randomized controlled trial of mobile closed-loop control, Diabetes Care source
Not checked in the free run.
- cites [212] Beck, 2022, A multicenter randomized trial evaluating fast-acting insulin aspart in the bionic pancreas in adults with type 1 diabetes, Diabetes Technol Ther source
Not checked in the free run.
- cites [213] Messer, 2022, Positive impact of the bionic pancreas on diabetes control in youth 6-17 years old with type 1 diabetes: a multicenter randomized trial, Diabetes Technol Ther source
Not checked in the free run.
- cites [214] Castellanos, 2023, The insulin-only bionic pancreas improves glycemic control in non-Hispanic White and minority adults and children with type 1 diabetes, Diabetes Care source
Not checked in the free run.
- cites [215] Russell, 2022, Multicenter, randomized trial of a bionic pancreas in type 1 diabetes, N Engl J Med source
Not checked in the free run.
- cites [216] Kruger, 2022, A multicenter randomized trial evaluating the insulin-only configuration of the bionic pancreas in adults with type 1 diabetes, Diabetes Technol Ther source
Not checked in the free run.
- Premisecitation§ Data From Pivotal Trials
AID use in pivotal trials reduced time spent in hypoglycemia.
“with consistent improvement in A1C, increase in TIR, especially overnight, as well as reduction of time spent in hypoglycemia (207-219).”
Quote in the paperSubstantial claim0 of 10 sources checked- cites [207] Kaur, 2019, Efficacy of hybrid closed-loop system in adults with type 1 diabetes and gastroparesis, Diabetes Technol Ther source
Not checked in the free run.
- cites [208] Brown, 2019, Six-month randomized, multicenter trial of closed-loop control in type 1 diabetes, N Engl J Med source
Not checked in the free run.
- cites [209] Sherr, 2020, Safety and performance of the Omnipod hybrid closed-loop system in adults, adolescents, and children with type 1 diabetes over 5 days under free-living conditions, Diabetes Technol Ther source
Not checked in the free run.
- cites [210] Lal, 2019, One year clinical experience of the first commercial hybrid closed-loop system, Diabetes Care source
Not checked in the free run.
- cites [211] Kovatchev, 2020, Randomized controlled trial of mobile closed-loop control, Diabetes Care source
Not checked in the free run.
- cites [212] Beck, 2022, A multicenter randomized trial evaluating fast-acting insulin aspart in the bionic pancreas in adults with type 1 diabetes, Diabetes Technol Ther source
Not checked in the free run.
- cites [213] Messer, 2022, Positive impact of the bionic pancreas on diabetes control in youth 6-17 years old with type 1 diabetes: a multicenter randomized trial, Diabetes Technol Ther source
Not checked in the free run.
- cites [214] Castellanos, 2023, The insulin-only bionic pancreas improves glycemic control in non-Hispanic White and minority adults and children with type 1 diabetes, Diabetes Care source
Not checked in the free run.
- cites [215] Russell, 2022, Multicenter, randomized trial of a bionic pancreas in type 1 diabetes, N Engl J Med source
Not checked in the free run.
- cites [216] Kruger, 2022, A multicenter randomized trial evaluating the insulin-only configuration of the bionic pancreas in adults with type 1 diabetes, Diabetes Technol Ther source
Not checked in the free run.
- Premisecitation§ Data From Pivotal Trials
AID systems may lower the risk of exercise-related hypoglycemia.
“These systems may also lower the risk of exercise-related hypoglycemia (219) and have been shown to have psychosocial benefits (221)(222)(223)(224)(225).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [219] Sherr, 2013, Reduced hypoglycemia and increased time in target using closed-loop insulin delivery during nights with or without antecedent afternoon exercise in type 1 diabetes, Diabetes Care source
Not checked in the free run.
- Premisecitation§ Data From Pivotal Trials
People starting AID with the highest baseline A1C or lowest TIR experience the greatest improvements.
“The greatest improvements were seen with AID when used in individuals with the highest baseline A1C or lowest TIR (220).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [220] Boughton, 2024, The role of automated insulin delivery technology in diabetes, Diabetologia source
Not checked in the free run.
- Premisecitation§ Data From Pivotal Trials
AID systems have psychosocial benefits.
“These systems may also lower the risk of exercise-related hypoglycemia (219) and have been shown to have psychosocial benefits (221)(222)(223)(224)(225).”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [221] Weissberg-Benchell, 2016, Psychosocial impact of the bionic pancreas during summer camp, J Diabetes Sci Technol source
Not checked in the free run.
- cites [222] Troncone, 2016, Evaluating the experience of children with type 1 diabetes and their parents taking part in an artificial pancreas clinical trial over multiple days in a diabetes camp setting, Diabetes Care source
Not checked in the free run.
- cites [223] Barnard, 2014, Closing the loop overnight at home setting: psychosocial impact for adolescents with type 1 diabetes and their parents, BMJ Open Diabetes Res Care source
Not checked in the free run.
- Premisecitation§ Data From Real-world Studies
Real-world data show AID systems provide the same glycemic benefits to Medicare and Medicaid beneficiaries with type 1 and type 2 diabetes.
“Finally, real-world data showed that AID systems provide the same glycemic benefits to Medicare and Medicaid beneficiaries with type 1 and type 2 diabetes, emphasizing that access to this technology should be made available regardless of A1C levels and should be based on the individual's needs (235).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [235] Forlenza, 2022, Real-world evidence supporting Tandem Control-IQ hybrid closed-loop success in the Medicare and Medicaid type 1 and type 2 diabetes populations, Diabetes Technol Ther source
Not checked in the free run.
- Premisecitation§ Data From Real-world Studies
Newer AID systems have shown increased time spent in automation.
“Newer systems have shown increased time spent in automation, and the real-world studies have retrospectively analyzed longer duration of system use compared with their respective pivotal trials, with most analyses occurring for more than 6 months and an average duration of 9 months (227).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [227] Considine, 2024, Real-world evidence of automated insulin delivery system use, Diabetes Technol Ther source
Not checked in the free run.
- Premisecitation§ Automated Insulin Delivery Systems in Pregnancy
In that trial, AID reduced time above 140 mg/dL compared with standard care.
“The secondary outcomes were also met, with less time spent above range (>140 mg/dL) in the AID group, greater overnight time in target range, and lower A1C (236).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [236] Lee, 2023, Automated insulin delivery in women with pregnancy complicated by type 1 diabetes, N Engl J Med source
Not checked in the free run.
- Rests on an assumption: Current FDA-approved AID systems, except one approved but not commercially available, have glucose goals not pregnancy-specific and algorithms not designed for pregnancy-specific goals.
- Premisecitation§ Data From Real-world Studies
Real-world AID studies include large numbers of users, sometimes 30-fold higher than pivotal trials.
“These studies include large numbers of users, at times even 30-fold higher than the number of people studied in AID pivotal trials (227).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [227] Considine, 2024, Real-world evidence of automated insulin delivery system use, Diabetes Technol Ther source
Not checked in the free run.
- Interpretationreasoning§ Data From Pivotal Trials
AID is becoming the standard of care for type 1 diabetes.
“AID is rapidly becoming the standard of care for people with type 1 diabetes and should be the preferred method of insulin delivery in these individuals.”
Quote in the paperSubstantial claim - Premisecitation§ Data From Pivotal Trials
AID systems are cost-effective in type 1 diabetes according to a literature review.
“A review of the literature on the health and economic value of AID systems in individuals with type 1 diabetes found that AID systems are cost-effective (226).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [226] Mathieu, 2024, The health economics of automated insulin delivery systems and the potential use of time in range in diabetes modeling: a narrative review, Diabetes Technol Ther source
Not checked in the free run.
- Premisecitation§ Automated Insulin Delivery Systems in Pregnancy
In a multicenter controlled trial of pregnant women with type 1 diabetes, time in pregnancy-specific target range 63-140 mg/dL was 10.5% higher with AID than standard care (P<0.001).
“The primary outcome of time spent in the pregnancy-specific target range of 63-140 mg/dL was found to be 10.5% higher in the AID group versus standard care (P < 0.001).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [236] Lee, 2023, Automated insulin delivery in women with pregnancy complicated by type 1 diabetes, N Engl J Med source
Not checked in the free run.
- Rests on an assumption: Current FDA-approved AID systems, except one approved but not commercially available, have glucose goals not pregnancy-specific and algorithms not designed for pregnancy-specific goals.
- Premisecitation§ Automated Insulin Delivery Systems in Pregnancy
In that trial, AID increased overnight time in target range.
“The secondary outcomes were also met, with less time spent above range (>140 mg/dL) in the AID group, greater overnight time in target range, and lower A1C (236).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [236] Lee, 2023, Automated insulin delivery in women with pregnancy complicated by type 1 diabetes, N Engl J Med source
Not checked in the free run.
- Rests on an assumption: Current FDA-approved AID systems, except one approved but not commercially available, have glucose goals not pregnancy-specific and algorithms not designed for pregnancy-specific goals.
- Premisecitation§ Automated Insulin Delivery Systems in Pregnancy
In that study, quality-of-life metrics improved in the AID group.
“Quality-of-life metrics were improved in the AID group in this study (239).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [239] Benhalima, 2024, Comparing advanced hybrid closed loop therapy and standard insulin therapy in pregnant women with type 1 diabetes (CRISTAL): a parallel-group, open-label, randomised controlled trial, Lancet Diabetes Endocrinol source
Not checked in the free run.
- Rests on an assumption: Current FDA-approved AID systems, except one approved but not commercially available, have glucose goals not pregnancy-specific and algorithms not designed for pregnancy-specific goals.
- Premisecitation§ Insulin Pumps and Automated Insulin Delivery Systems in People With Type 2 and Other Types of Diabetes
Reductions in A1C have been reported in some studies of insulin pump use in type 2 diabetes.
“Similar to data on insulin pump use in people with type 1 diabetes, reductions in A1C levels have been reported in some studies (243,246).”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [243] Layne, 2017, Efficacy of a tubeless patch pump in patients with type 2 diabetes previously treated with multiple daily injections, J Diabetes Sci Technol source
Not checked in the free run.
- cites [246] Reznik, 2014, Insulin pump treatment compared with multiple daily injections for treatment of type 2 diabetes (OpT2mise): a randomised open-label controlled trial, Lancet source
Not checked in the free run.
- Premisecitation§ Automated Insulin Delivery Systems in Pregnancy
In that pilot RCT, there were no statistically significant differences in glycemic risk or glycemic variability between hybrid closed-loop and SAP groups at any point during pregnancy or postpartum.
“There were no statistically significant differences in measures of glycemic risk or in measures of glycemic variability between the hybrid closed-loop and the SAP groups at any point during pregnancy or postpartum (238).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [238] King, 2024, Glycemic variability in pregnant individuals using assisted hybrid closed-loop therapy versus sensor-augmented pump therapy, J Diabetes Sci Technol source
Not checked in the free run.
- Rests on an assumption: Current FDA-approved AID systems, except one approved but not commercially available, have glucose goals not pregnancy-specific and algorithms not designed for pregnancy-specific goals.
- Premisecitation§ Automated Insulin Delivery Systems in Pregnancy
In that trial, AID lowered A1C.
“The secondary outcomes were also met, with less time spent above range (>140 mg/dL) in the AID group, greater overnight time in target range, and lower A1C (236).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [236] Lee, 2023, Automated insulin delivery in women with pregnancy complicated by type 1 diabetes, N Engl J Med source
Not checked in the free run.
- Rests on an assumption: Current FDA-approved AID systems, except one approved but not commercially available, have glucose goals not pregnancy-specific and algorithms not designed for pregnancy-specific goals.
- Premisecitation§ Automated Insulin Delivery Systems in Pregnancy
In that pilot RCT, pregnancy-specific TIR was greater in the SAP group in the third trimester.
“Time at <63 mg/dL was lower in the hybrid closed-loop group, whereas percentage of the pregnancy-specific TIR was greater in the SAP group in the third trimester, with similar safety and adverse pregnancy outcomes between groups (237).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [237] Polsky, 2024, Randomized trial of assisted hybrid closed-loop therapy versus sensor-augmented pump therapy in pregnancy, Diabetes Technol Ther source
Not checked in the free run.
- Rests on an assumption: Current FDA-approved AID systems, except one approved but not commercially available, have glucose goals not pregnancy-specific and algorithms not designed for pregnancy-specific goals.
- Premisecitation§ Automated Insulin Delivery Systems in Pregnancy
In another study of AID with lowest glucose target 100 mg/dL, 24-h pregnancy-specific TIR did not differ between AID and standard care.
“The 24-h percentage of pregnancy-specific TIR was not different between groups, but the overnight percentage of pregnancy-specific TIR was higher in the AID group while using assistive techniques.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [239] Benhalima, 2024, Comparing advanced hybrid closed loop therapy and standard insulin therapy in pregnant women with type 1 diabetes (CRISTAL): a parallel-group, open-label, randomised controlled trial, Lancet Diabetes Endocrinol source
Not checked in the free run.
- Rests on an assumption: Current FDA-approved AID systems, except one approved but not commercially available, have glucose goals not pregnancy-specific and algorithms not designed for pregnancy-specific goals.
- Premisecitation§ Automated Insulin Delivery Systems in Pregnancy
In that study, overnight pregnancy-specific TIR was higher in the AID group while using assistive techniques.
“The 24-h percentage of pregnancy-specific TIR was not different between groups, but the overnight percentage of pregnancy-specific TIR was higher in the AID group while using assistive techniques.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [239] Benhalima, 2024, Comparing advanced hybrid closed loop therapy and standard insulin therapy in pregnant women with type 1 diabetes (CRISTAL): a parallel-group, open-label, randomised controlled trial, Lancet Diabetes Endocrinol source
Not checked in the free run.
- Rests on an assumption: Current FDA-approved AID systems, except one approved but not commercially available, have glucose goals not pregnancy-specific and algorithms not designed for pregnancy-specific goals.
- Premisecitation§ Automated Insulin Delivery Systems in Pregnancy
In a pilot RCT of pregnant women with type 1 diabetes, time in hypoglycemia <54 mg/dL did not differ between hybrid closed-loop and SAP groups.
“This system did not have pregnancy-specific glucose targets; however, the results showed that the time in hypoglycemia <54 mg/dL did not differ between groups.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [237] Polsky, 2024, Randomized trial of assisted hybrid closed-loop therapy versus sensor-augmented pump therapy in pregnancy, Diabetes Technol Ther source
Not checked in the free run.
- Rests on an assumption: Current FDA-approved AID systems, except one approved but not commercially available, have glucose goals not pregnancy-specific and algorithms not designed for pregnancy-specific goals.
- Premisecitation§ Automated Insulin Delivery Systems in Pregnancy
In that pilot RCT, time <63 mg/dL was lower in the hybrid closed-loop group.
“Time at <63 mg/dL was lower in the hybrid closed-loop group, whereas percentage of the pregnancy-specific TIR was greater in the SAP group in the third trimester, with similar safety and adverse pregnancy outcomes between groups (237).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [237] Polsky, 2024, Randomized trial of assisted hybrid closed-loop therapy versus sensor-augmented pump therapy in pregnancy, Diabetes Technol Ther source
Not checked in the free run.
- Rests on an assumption: Current FDA-approved AID systems, except one approved but not commercially available, have glucose goals not pregnancy-specific and algorithms not designed for pregnancy-specific goals.
- Premisecitation§ Open-Source Automated Insulin Dosing
OS-AID algorithms provide precise code governing operation, allowing HCP and people with diabetes to understand risks and benefits.
“Open-source automated insulin dosing (OS-AID) algorithms provide the precise code that governs their operation, so health care professionals and people with diabetes can have a more complete understanding of risks and benefits (254).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [254] Braune, 2022, Open-source automated insulin delivery: international consensus statement and practical guidance for health-care professionals, Lancet Diabetes Endocrinol source
Not checked in the free run.
- Rests on an assumption: OS-AID algorithms are largely designed, maintained, and curated by people with diabetes and their loved ones.
- Premisecitation§ Insulin Pumps and Automated Insulin Delivery Systems in People With Type 2 and Other Types of Diabetes
In clinically insulin-deficient people treated with intensive insulin therapy, measurable C-peptide levels do not correlate with response to therapy.
“For people with diabetes judged to be clinically insulin deficient who are treated with an intensive insulin therapy, the presence or absence of measurable C-peptide levels does not correlate with response to therapy (171).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [171] Vigersky, 2018, Improved HBa1c, total daily insulin dose, and treatment satisfaction with insulin pump therapy compared to multiple daily insulin injections in patients with type 2 diabetes irrespective of baseline c-peptide levels, Endocr Pract source
Not checked in the free run.
- Premisecitation§ Insulin Pumps and Automated Insulin Delivery Systems in People With Type 2 and Other Types of Diabetes
A recent RCT of older adults with type 2 diabetes using MDI but unable to manage insulin on their own showed TIR increase of 27% over 12 weeks of AID plus tailored home health care.
“Finally, a recent RCT of older adults with type 2 diabetes who used MDI but were unable to manage insulin therapy on their own revealed an increase of TIR of 27% over 12 weeks of AID system use in addition to tailored home health care services (250).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [250] Reznik, 2024, Should people with type 2 diabetes treated by multiple daily insulin injections with home health care support be switched to hybrid closed-loop? The CLOSE AP+ randomized controlled trial, Diabetes Obes Metab source
Not checked in the free run.
- Rests on an assumption: Use of insulin pumps and AID systems in type 2 diabetes is still limited, and only one system is FDA approved for type 2 diabetes.
- Premisecitation§ Insulin Pumps and Automated Insulin Delivery Systems in People With Type 2 and Other Types of Diabetes
A small single-arm prospective study in adults with type 2 diabetes on MDI who started AID showed TIR improvement of 15% at 6 weeks.
“Nevertheless, data are increasing; a small, single-arm prospective study in adults with type 2 diabetes who were on MDI and started an AID system revealed improvement of TIR by 15% at 6 weeks (248).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [248] Levy, 2024, Beneficial effects of Control-IQ automated insulin delivery in basal-bolus and basal-only insulin users with type 2 diabetes, Clin Diabetes source
Not checked in the free run.
- Rests on an assumption: Use of insulin pumps and AID systems in type 2 diabetes is still limited, and only one system is FDA approved for type 2 diabetes.
- Premisecitation§ Insulin Pumps and Automated Insulin Delivery Systems in People With Type 2 and Other Types of Diabetes
Real-world studies have shown benefits of insulin pumps/AID in adults with type 2 diabetes.
“Real-world studies have also shown benefits of these technologies in adults with type 2 diabetes (235,251).”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [235] Forlenza, 2022, Real-world evidence supporting Tandem Control-IQ hybrid closed-loop success in the Medicare and Medicaid type 1 and type 2 diabetes populations, Diabetes Technol Ther source
Not checked in the free run.
- cites [251] Davis, 2023, Safety and efficacy of the Omnipod 5 automated insulin delivery system in adults with type 2 diabetes: from injections to hybrid closed-loop therapy, Diabetes Care source
Not checked in the free run.
- Rests on an assumption: Use of insulin pumps and AID systems in type 2 diabetes is still limited, and only one system is FDA approved for type 2 diabetes.
- Premisecitation§ Insulin Pumps and Automated Insulin Delivery Systems in People With Type 2 and Other Types of Diabetes
Other studies showed reduction of total daily insulin in AID group previously using MDI.
“Of note, an increase in total daily insulin dose was noted in the subjects while on the AID system (249), whereas other studies have shown either nonsignificant trends for a lower total daily dose of insulin in the AID group (250) or a reduction of total daily insulin in the AID group previously using MDI (251).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [251] Davis, 2023, Safety and efficacy of the Omnipod 5 automated insulin delivery system in adults with type 2 diabetes: from injections to hybrid closed-loop therapy, Diabetes Care source
Not checked in the free run.
- Rests on an assumption: Use of insulin pumps and AID systems in type 2 diabetes is still limited, and only one system is FDA approved for type 2 diabetes.
- Premisecitation§ Open-Source Automated Insulin Dosing
A single-center trial in adolescents with type 1 diabetes compared AndroidAPS with quantitative, qualitative, or no carbohydrate announcements and found TIR preserved across arms.
“In a singlecenter study of adolescents with type 1 diabetes randomized to AndroidAPS with quantitative carbohydrate announcements, qualitative announcements, and no announcements, TIR was preserved across groups (258).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [258] Petruzelkova, 2023, First use of open-source automated insulin delivery AndroidAPS in full closed-loop scenario: Pancreas4ALL randomized pilot study, Diabetes Technol Ther source
Not checked in the free run.
- Rests on an assumption: There are two main available algorithms, Open-APS and Loop, implemented on a variety of platforms.
- Premisecitation§ Insulin Pumps and Automated Insulin Delivery Systems in People With Type 2 and Other Types of Diabetes
Other studies showed nonsignificant trends for lower total daily insulin dose in AID group.
“Of note, an increase in total daily insulin dose was noted in the subjects while on the AID system (249), whereas other studies have shown either nonsignificant trends for a lower total daily dose of insulin in the AID group (250) or a reduction of total daily insulin in the AID group previously using MDI (251).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [250] Reznik, 2024, Should people with type 2 diabetes treated by multiple daily insulin injections with home health care support be switched to hybrid closed-loop? The CLOSE AP+ randomized controlled trial, Diabetes Obes Metab source
Not checked in the free run.
- Rests on an assumption: Use of insulin pumps and AID systems in type 2 diabetes is still limited, and only one system is FDA approved for type 2 diabetes.
- Premisecitation§ Open-Source Automated Insulin Dosing
Prospective real-world data from 558 adults and children with type 1 diabetes on Loop was used to support FDA clearance of Tidepool Loop.
“Prospective realworld data from 558 adults and children with type 1 diabetes on this system (255) was used to support the FDA clearance of a variant called Tidepool Loop (259).”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [255] Lum, 2021, A real-world prospective study of the safety and effectiveness of the loop open source automated insulin delivery system, Diabetes Technol Ther source
Not checked in the free run.
- cites [259] Braune, 2023, The first regulatory clearance of an open-source automated insulin delivery algorithm, J Diabetes Sci Technol source
Not checked in the free run.
- Rests on an assumption: Loop is an open-source model predictive control algorithm implemented on iPhones as an app.
- Premisecitation§ Insulin Pumps and Automated Insulin Delivery Systems in People With Type 2 and Other Types of Diabetes
In that crossover trial, total daily insulin dose increased while on AID.
“Of note, an increase in total daily insulin dose was noted in the subjects while on the AID system (249), whereas other studies have shown either nonsignificant trends for a lower total daily dose of insulin in the AID group (250) or a reduction of total daily insulin in the AID group previously using MDI (251).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [249] Borel, 2024, Closed-loop insulin therapy for people with type 2 diabetes treated with an insulin pump: a 12-week multicenter, open-label randomized, controlled, crossover trial, Diabetes Care source
Not checked in the free run.
- Rests on an assumption: Use of insulin pumps and AID systems in type 2 diabetes is still limited, and only one system is FDA approved for type 2 diabetes.
- Premisecitation§ Digital Health Technology
Some online programs aim to treat prediabetes and prevent progression to diabetes, often following the Diabetes Prevention Program model.
“Some programs aim to treat prediabetes and prevent progression to diabetes, often following the model of the Diabetes Prevention Program (264,265).”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [264] Sepah, 2014, Translating the Diabetes Prevention Program into an online social network: validation against CDC standards, Diabetes Educ source
Not checked in the free run.
- cites [265] Kaufman, 2019, Using digital health technology to prevent and treat diabetes, Diabetes Technol Ther source
Not checked in the free run.
- Premisecitation§ Inpatient Care
With the COVID-19 pandemic, the FDA exercised enforcement discretion to allow temporary CGM use in hospitals for patient monitoring.
“With the advent of the coronavirus disease 2019 pandemic, the FDA exercised enforcement discretion by allowing CGM device use temporarily in the hospital for patient monitoring (282).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [282] U.S. Food and Drug Administration . Enforcement Policy for Non-Invasive Remote Monitoring Devices Used to Support Patient Monitoring During the Coronavirus Disease 2019 (COVID-19) Public Health Emergency (revised), 2020. Accessed 15 August 2024. Available from https://www.fda.gov/media/136290/download
Not checked in the free run.
- Premisecitation§ Digital Health Technology
Other online programs assist in improving diabetes outcomes by remotely monitoring clinical data and providing feedback and coaching.
“Others assist in improving diabetes outcomes by remotely monitoring clinical data (for instance, wireless monitoring of glucose levels, weight, or blood pressure) and providing feedback and coaching (266-271).”
Quote in the paperNot a substantial claim0 of 6 sources checked- cites [266] Öberg, 2018, Perceptions of persons with type 2 diabetes treated in swedish primary health care: qualitative study on using eHealth services for self-management support, JMIR Diabetes source
Not checked in the free run.
- cites [267] Bollyky, 2018, Remote lifestyle coaching plus a connected glucose meter with certified diabetes educator support improves glucose and weight loss for people with type 2 diabetes, J Diabetes Res source
Not checked in the free run.
- cites [268] Wilhide Iii, 2016, Evidence-based mHealth chronic disease mobile app intervention design: development of a framework, JMIR Res Protoc source
Not checked in the free run.
- cites [269] Dixon, 2020, A virtual type 2 diabetes clinic using continuous glucose monitoring and endocrinology visits, J Diabetes Sci Technol source
Not checked in the free run.
- cites [270] Yang, 2020, Effect of a mobile phone-based glucose-monitoring and feedback system for type 2 diabetes management in multiple primary care clinic settings: cluster randomized controlled trial, JMIR Mhealth Uhealth source
Not checked in the free run.
- cites [271] Levine, 2020, Reviewing U.S. connected diabetes care: the newest member of the team, Diabetes Technol Ther source
Not checked in the free run.
- Premisecitation§ Digital Health Technology
Text messaging approaches tied to lifestyle and treatment programs vary in effectiveness.
“There are text messaging approaches that tie into a variety of different types of lifestyle and treatment programs, which vary in terms of their effectiveness (272,273).”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [272] McGill, 2019, Text-message responsiveness to blood glucose monitoring reminders is associated with HbA1c benefit in teenagers with type 1 diabetes, Diabet Med source
Not checked in the free run.
- cites [273] Shen, 2018, Effectiveness of internet-based interventions on glycemic control in patients with type 2 diabetes: meta-analysis of randomized controlled trials, J Med Internet Res source
Not checked in the free run.
- Interpretationcitation§ Inpatient Care
Studies assessing effectiveness of inpatient CGM may ultimately lead to approved use of CGM for monitoring hospitalized individuals.
“Studies have been published assessing the effectiveness of this approach, which may ultimately lead to the approved use of CGM for monitoring hospitalized individuals (277,286-295).”
Quote in the paperSubstantial claim0 of 10 sources checked- cites [277] Galindo, 2020, Continuous glucose monitors and automated insulin dosing systems in the hospital consensus guideline, J Diabetes Sci Technol source
Not checked in the free run.
- cites [286] Galindo, 2020, Implementation of continuous glucose monitoring in the hospital: emergent considerations for remote glucose monitoring during the COVID-19 pandemic, J Diabetes Sci Technol source
Not checked in the free run.
- cites [287] Ushigome, 2021, Usefulness and safety of remote continuous glucose monitoring for a severe COVID-19 patient with diabetes, Diabetes Technol Ther source
Not checked in the free run.
- cites [288] Korytkowski, 2022, Management of hyperglycemia in hospitalized adult patients in non-critical care settings: an Endocrine Society clinical practice guideline, J Clin Endocrinol Metab source
Not checked in the free run.
- cites [289] Longo, 2022, Use and accuracy of inpatient CGM during the COVID-19 pandemic: an observational study of general medicine and ICU patients, J Diabetes Sci Technol source
Not checked in the free run.
- cites [290] Davis, 2021, Accuracy of Dexcom G6 continuous glucose monitoring in non-critically ill hospitalized patients with diabetes, Diabetes Care source
Not checked in the free run.
- cites [291] Baker, 2022, Practical implementation of remote continuous glucose monitoring in hospitalized patients with diabetes, Am J Health Syst Pharm source
Not checked in the free run.
- cites [292] Wright, 2022, Accuracy of continuous glucose monitors for inpatient diabetes management, J Diabetes Sci Technol source
Not checked in the free run.
- cites [293] Spanakis, 2022, Continuous glucose monitoring-guided insulin administration in hospitalized patients with diabetes: a randomized clinical trial, Diabetes Care source
Not checked in the free run.
- cites [294] Singh, 2020, Reducing inpatient hypoglycemia in the general wards using real-time continuous glucose monitoring: the glucose telemetry system, a randomized clinical trial, Diabetes Care source
Not checked in the free run.
- Premisenone given§ Inpatient Care
Maltose produces falsely elevated blood glucose readings on meters that use the unmodified glucose dehydrogenase method.
“Maltose* | Falsely higher blood glucose values”
Quote in the paperNot a substantial claim - Premisecitation§ Inpatient Care
Data are emerging on inpatient use of AID systems and their challenges.
“Similarly, data are emerging on the inpatient use of AID systems and their challenges (277,296,297).”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [277] Galindo, 2020, Continuous glucose monitors and automated insulin dosing systems in the hospital consensus guideline, J Diabetes Sci Technol source
Not checked in the free run.
- cites [296] Pelkey, 2023, Hybrid closed-loop insulin pump technology can be safely used in the inpatient setting, Endocr Pract source
Not checked in the free run.
- cites [297] Madhun, 2023, Attitudes and behaviors with diabetes technology use in the hospital: multicenter survey study in the United States, Diabetes Technol Ther source
Not checked in the free run.
- Premisereasoning§ Inpatient Care
When used in a clinical trial or when clinical circumstances require it, CGM can be used to manage hospitalized individuals in conjunction with BGM.
“When used in the setting of a clinical trial or when clinical circumstances (such as during a shortage of personal protective equipment) require it, CGM can be used to manage hospitalized individuals in conjunction with BGM.”
Quote in the paperSubstantial claim - Premisenone given§ Inpatient Care
Sorbitol given intravenously or as peritoneal dialysis solution produces sensor readings higher than actual glucose with the Senseonics Eversense system.
“Sorbitol (intravenously or as peritoneal | Senseonics Eversense | Higher sensor readings than actual glucose”
Quote in the paperNot a substantial claim - Premisenone given§ Inpatient Care
Acetaminophen at more than 4 g/day produces sensor readings higher than actual glucose with the Dexcom G6 and Dexcom G7 systems.
“>4 g/day | Dexcom G6, Dexcom G7 | Higher sensor readings than actual glucose”
Quote in the paperNot a substantial claim - Premisenone given§ Inpatient Care
Hydroxyurea produces sensor readings higher than actual glucose with the Dexcom G6, Dexcom G7, and Medtronic Guardian systems.
“Hydroxyurea | Dexcom G6, Dexcom G7, Medtronic Guardian | Higher sensor readings than actual glucose”
Quote in the paperNot a substantial claim - Premisenone given§ Inpatient Care
Ascorbic acid (vitamin C) at more than 500 mg/day produces sensor readings higher than actual glucose with the FreeStyle Libre 14 day, FreeStyle Libre 2, and FreeStyle Libre 3 systems.
“Ascorbic acid (vitamin C), >500 mg/day | FreeStyle Libre 14 day, FreeStyle Libre 2, | Higher sensor readings than actual glucose”
Quote in the paperNot a substantial claim - Premisenone given§ Inpatient Care
Acetaminophen at any dose produces sensor readings higher than actual glucose with the Medtronic Guardian system.
“Any dose | Medtronic Guardian | Higher sensor readings than actual glucose”
Quote in the paperNot a substantial claim - Premisenone given§ Inpatient Care
N-acetylcysteine produces falsely elevated blood glucose readings on glucose meters that use the glucose dehydrogenase/pyrroloquinoline quinone (GDH/PQQ) method.
“N-Acetylcysteine † | Falsely higher blood glucose values”
Quote in the paperNot a substantial claim - Premisenone given§ Inpatient Care
Ascorbic acid (vitamin C) at more than 1,000 mg/day produces sensor readings higher than actual glucose with the FreeStyle Libre 2 Plus and FreeStyle Libre 3 Plus systems.
“Ascorbic acid (vitamin C), >1,000 mg/day | FreeStyle Libre 2 Plus, FreeStyle Libre 3 Plus | Higher sensor readings than actual glucose”
Quote in the paperNot a substantial claim - Premisenone given§ Inpatient Care
Mannitol given intravenously or as peritoneal dialysis solution produces sensor readings higher than actual glucose with the Senseonics Eversense system.
“Mannitol (intravenously or as peritoneal | Senseonics Eversense | Higher sensor readings than actual glucose”
Quote in the paperNot a substantial claim
- May combine two claims. 60
- The quote only partly states this claim. 1
- Classified as probably not a substantial claim. 13
May combine two claims.
Premisecitation§ Initiation of Device UseIn youth with newly diagnosed type 1 diabetes, starting an AID system within 21 days of diagnosis resulted in 10% higher time in range and lower A1C at 12 months compared with usual care.
“In an openlabel, multicenter, randomized, parallel clinical trial enrolling youth with newly diagnosed type 1 diabetes, initiation of an AID system within 21 days from diagnosis showed 10% higher time in range (TIR) (70-180 mg/dL [3.9-10.0mmol/L]) and lower A1C at 12 months versus usual care (13).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [13] Boughton, 2024, The effect of closed-loop glucose control on C-peptide secretion in youth with newly diagnosed type 1 diabetes: the CLOuD RCT
Not checked in the free run.
May combine two claims.
Premisecitation§ Initiation of Device UseIn youth with type 1 diabetes, starting CGM soon after diagnosis lowers A1C and is associated with high parental satisfaction and reliance on CGM for diabetes management.
“In addition, early CGM initiation after diagnosis of type 1 diabetes in youth has been shown to decrease A1C levels and is associated with high parental satisfaction and reliance on this technology for diabetes management (5,6).”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [5] Prahalad, 2022, Teamwork, targets, technology, and tight control in newly diagnosed type 1 diabetes: the Pilot 4T Study, J Clin Endocrinol Metab source
Not checked in the free run.
- cites [6] Tanenbaum, 2021, “I was ready for it at the beginning”: parent experiences with early introduction of continuous glucose monitoring following their child's type 1 diabetes diagnosis, Diabet Med source
Not checked in the free run.
May combine two claims.
Premisecitation§ Initiation of Device UseUse of diabetes technology overall improves A1C and increases the proportion of people achieving A1C below 7%.
“In addition, use of diabetes technology overall improves A1C and increases the number of people achieving an A1C <7% (14).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [14] Karakus, 2023, Association between diabetes technology use and glycemic outcomes in adults with type 1 diabetes over a decade, Diabetes Care source
Not checked in the free run.
May combine two claims.
Premisecitation§ People With Diabetes Using Basal Insulin and/or Oral Agents and Noninsulin InjectablesIn trials where structured BGM data were used to adjust medications, A1C reductions were greater (0.3%), but A1C did not change significantly without such structured therapy adjustment.
“Reductions in A1C levels were greater (À0.3%) in trials where structured BGM data were used to adjust medications, but A1C levels were not changed significantly without such structured diabetes therapy adjustment (35).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [35] Mannucci, 2018, Effects of structured versus unstructured self-monitoring of blood glucose on glucose control in patients with non-insulin-treated type 2 diabetes: a meta-analysis of randomized controlled trials, J Diabetes Sci Technol source
Not checked in the free run.
May combine two claims.
Premisecitation§ People With Diabetes Using Basal Insulin and/or Oral Agents and Noninsulin InjectablesMeta-analyses suggest BGM can reduce A1C by 0.25-0.3% at 6 months, but the effect was attenuated at 12 months in one analysis.
“Meta-analyses have suggested that BGM can reduce A1C levels by 0.25-0.3%at 6 months (33-35), but the effect was attenuated at 12 months in one analysis (33).”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [33] Malanda, 2012, Self-monitoring of blood glucose in patients with type 2 diabetes mellitus who are not using insulin, Cochrane Database Syst Rev
Not checked in the free run.
- cites [34] Willett, 2012, Meta-analysis: self-monitoring in non-insulin-treated type 2 diabetes improved HbA1c by 0.25%, Ann Intern Med source
Not checked in the free run.
- cites [35] Mannucci, 2018, Effects of structured versus unstructured self-monitoring of blood glucose on glucose control in patients with non-insulin-treated type 2 diabetes: a meta-analysis of randomized controlled trials, J Diabetes Sci Technol source
Not checked in the free run.
May combine two claims.
Premisecitation§ People With Diabetes on Intensive Insulin TherapiesIn a database study of almost 27,000 children and adolescents with type 1 diabetes, after adjusting for multiple confounders, increased daily BGM frequency was significantly associated with lower A1C (0.2% per additional check per day) and fewer acute complications.
“A database study of almost 27,000 children and adolescents with type 1 diabetes showed that, after adjusting for multiple confounders, increased daily frequency of BGM was significantly associated with lower A1C levels (À0.2% per additional check per day) and with fewer acute complications (29).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [29] Ziegler, 2011, Frequency of SMBG correlates with HbA1c and acute complications in children and adolescents with type 1 diabetes, Pediatr Diabetes source
Not checked in the free run.
May combine two claims.
Premisecitation§ People With Diabetes Using Basal Insulin and/or Oral Agents and Noninsulin InjectablesIn people with type 2 diabetes not taking insulin, routine glucose monitoring may have limited additional clinical benefit; by itself, even with education, it has shown limited improvement in outcomes.
“In people with type 2 diabetes not taking insulin, routine glucose monitoring may be of limited additional clinical benefit.By itself, even when combined with education, this practice has shown limited improvement in outcomes (31).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [31] Young, 2017, Glucose self-monitoring in non-insulin-treated patients with type 2 diabetes in primary care settings: a randomized trial, JAMA Intern Med source
Not checked in the free run.
May combine two claims.
Interpretationreasoning§ People With Diabetes Using Basal Insulin and/or Oral Agents and Noninsulin InjectablesPerforming BGM alone does not lower blood glucose levels; to be useful, the information must be integrated into clinical and self-management treatment plans.
“A key consideration is that performing BGM alone does not lower blood glucose levels.To be useful, the information must be integrated into clinical and self-management treatment plans.”
Quote in the paperSubstantial claimMay combine two claims.
Premisecitation§ Glucose Meter InaccuracyGlucose oxidase monitors are sensitive to oxygen and should only be used with capillary blood in people with normal oxygen saturation; high oxygen tensions may cause false low-glucose readings and low oxygen tensions may cause falsely elevated glucose readings.
“Glucose oxidase monitors are sensitive to the oxygen available and should only be used with capillary blood in people with normal oxygen saturation.Higher oxygen tensions (i.e., arterial blood or oxygen therapy) may result in false low-glucose readings, and low oxygen tensions (i.e., high altitude, hypoxia, or venous blood readings) may lead to falsely elevated glucose readings.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [37] Sacks, 2023, Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus, Diabetes Care source
Not checked in the free run.
May combine two claims.
Premisecitation§ Data From Randomized Controlled TrialsThe primary outcome was met and showed benefit in adults of all ages, including seniors.
“The primary outcome was met and showed benefit in adults of all ages (38,53,54), including seniors (55-57).”
Quote in the paperSubstantial claim0 of 6 sources checked- cites [38] Tamborlane, 2008, Continuous glucose monitoring and intensive treatment of type 1 diabetes, N Engl J Med source
Not checked in the free run.
- cites [53] Friedman, 2023, Beyond A1C: exploring continuous glucose monitoring metrics in managing diabetes, Endocr Connect source
Not checked in the free run.
- cites [54] Teo, 2022, Effectiveness of continuous glucose monitoring in maintaining glycaemic control among people with type 1 diabetes mellitus: a systematic review of randomised controlled trials and meta-analysis, Diabetologia source
Not checked in the free run.
- cites [55] Pratley, 2020, Effect of continuous glucose monitoring on hypoglycemia in older adults with type 1 diabetes: a randomized clinical trial, JAMA source
Not checked in the free run.
- cites [56] Miller, 2022, Benefit of continuous glucose monitoring in reducing hypoglycemia is sustained through 12 months of use among older adults with type 1 diabetes, Diabetes Technol Ther source
Not checked in the free run.
- cites [57] Bao, 2022, Effectiveness of continuous glucose monitoring in older adults with type 2 diabetes treated with basal insulin, Diabetes Technol Ther source
Not checked in the free run.
May combine two claims.
Premisecitation§ Data From Randomized Controlled TrialsRCT data on rtCGM use in individuals with type 2 diabetes on MDI, mixed therapies, and basal insulin consistently show reductions in A1C and increases in TIR but not a reduction in hypoglycemia rates.
“RCT data on rtCGM use in individuals with type 2 diabetes on MDI (59), mixed therapies (10, 60), and basal insulin (61,62) have consistently shown reductions in A1C levels and increases in TIR (70-180 mg/dL [3.9-10 mmol/L]) but not a reduction in rates of hypoglycemia (63).”
Quote in the paperSubstantial claim0 of 5 sources checked- cites [59] Beck, 2017, Continuous glucose monitoring versus usual care in patients with type 2 diabetes receiving multiple daily insulin injections: a randomized trial, Ann Intern Med source
Not checked in the free run.
- cites [10] Grace, 2022, Use of real-time continuous glucose monitoring improves glycemic control and other clinical outcomes in type 2 diabetes patients treated with less intensive therapy, Diabetes Technol Ther source
Not checked in the free run.
- cites [60] Ehrhardt, 2011, The effect of real-time continuous glucose monitoring on glycemic control in patients with type 2 diabetes mellitus, J Diabetes Sci Technol source
Not checked in the free run.
- cites [61] Martens, 2021, Effect of continuous glucose monitoring on glycemic control in patients with type 2 diabetes treated with basal insulin: a randomized clinical trial, JAMA source
Not checked in the free run.
- cites [62] Price, 2021, Episodic real-time CGM use in adults with type 2 diabetes: results of a pilot randomized controlled trial, Diabetes Ther source
Not checked in the free run.
The quote only partly states this claim.
Premisecitation§ Data From Randomized Controlled TrialsBehavioral support of parents of young children with diabetes using rtCGM reduced hypoglycemia concerns and diabetes distress.
“children with diabetes using rtCGM showed the benefits of reducing hypoglycemia concerns and diabetes distress (38,49,58).”
Quote in the paperNot a substantial claim0 of 3 sources checked- cites [38] Tamborlane, 2008, Continuous glucose monitoring and intensive treatment of type 1 diabetes, N Engl J Med source
Not checked in the free run.
- cites [49] Strategies to Enhance New CGM Use in Early Childhood (SENCE) Study Group, 2021, A randomized clinical trial assessing continuous glucose monitoring (CGM) use with standardized education with or without a family behavioral intervention compared with fingerstick blood glucose monitoring in very young children with type 1 diabetes, Diabetes Care source
Not checked in the free run.
- cites [58] Van Name, 2023, Long-term continuous glucose monitor use in very young children with type 1 diabetes: one-year results from the SENCE study, J Diabetes Sci Technol source
Not checked in the free run.
May combine two claims.
Premisecitation§ Data From Randomized Controlled TrialsIn a study of individuals with type 1 or type 2 diabetes taking insulin, the primary outcome of reduced severe hypoglycemia was not met, and severe hypoglycemia incidence did not differ significantly between isCGM users and the BGM group.
“In a study of individuals with type 1 or type 2 diabetes taking insulin, the primary outcome of a reduction in severe hypoglycemia was not met and the incidence of severe hypoglycemia was not significantly different between isCGM users and the BGM group (71).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [71] Davis, 2020, Efficacy of intermittently scanned continuous glucose monitoring in the prevention of recurrent severe hypoglycemia, Diabetes Technol Ther source
Not checked in the free run.
May combine two claims.
Premisecitation§ Data From Randomized Controlled TrialsIn an RCT, isCGM plus diabetes education versus diabetes education alone decreased A1C, increased TIR, and increased time in tight target range (70-140 mg/dL) in the isCGM-plus-education group.
“Additionally, benefits of isCGM were also reported in an RCT where the use of isCGM plus diabetes education versus diabetes education alone showed decreased A1C levels and increased TIR as well as increased time in tight target range (70-140 mg/dL [3.9-7.8 mmol/L]) in the isCGMplus-education group (8).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [8] Aronson, 2023, IMpact of flash glucose Monitoring in pEople with type 2 Diabetes Inadequately controlled with non-insulin Antihyperglycaemic ThErapy (IMMEDIATE): a randomized controlled trial, Diabetes Obes Metab source
Not checked in the free run.
May combine two claims.
Interpretationnone given§ Data From Randomized Controlled TrialsRCT data for isCGM are fewer but increasing.
“RCT data for isCGM are fewer but increasing.”
Quote in the paperNot a substantial claimMay combine two claims.
Premisecitation§ Data From Randomized Controlled TrialsRCT data for rtCGM benefits in people with type 2 diabetes not using insulin are increasing and generally show greater benefits of CGM compared with BGM for A1C, TIR, TBR, and TAR, as well as greater user-reported satisfaction.
“RCT data for rtCGM benefits in people with type 2 diabetes not using insulin are increasing and generally have shown greater benefits of CGM compared with BGM for A1C, TIR, time below range (TBR), and time above range (TAR) as well as greater user-reported satisfaction (66).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [66] Ferreira, 2024, Continuous glucose monitoring systems in noninsulin-treated people with type 2 diabetes: a systematic review and meta-analysis of randomized controlled trials, Diabetes Technol Ther source
Not checked in the free run.
May combine two claims.
Premisecitation§ Data From Randomized Controlled TrialsIn adults with type 2 diabetes using insulin, one study did not meet its primary A1C reduction end point but achieved a secondary reduction in hypoglycemia, and another study met its primary Diabetes Treatment Satisfaction Questionnaire score end point and a secondary A1C reduction end point.
“In adults with type 2 diabetes using insulin, two studies were done: one study did not meet its primary end point of A1C level reduction (69) but achieved a secondary end point of a reduction in hypoglycemia, and the other study met its primary end point of an improvement in the Diabetes Treatment Satisfaction Questionnaire score as well as a secondary end point of A1C level reduction (70).”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [69] Haak, 2017, Flash glucose-sensing technology as a replacement for blood glucose monitoring for the management of insulin-treated type 2 diabetes: a multicenter, open-label randomized controlled trial, Diabetes Ther source
Not checked in the free run.
- cites [70] Yaron, 2019, Effect of flash glucose monitoring technology on glycemic control and treatment satisfaction in patients with type 2 diabetes, Diabetes Care source
Not checked in the free run.
May combine two claims.
Premisecitation§ Data From Randomized Controlled TrialsCGM discontinuation in individuals with type 2 diabetes on basal insulin caused partial reversal of A1C reduction and TIR improvements, suggesting that continued CGM use achieves the greatest benefits.
“CGM discontinuation in individuals with type 2 diabetes on basal insulin caused partial reversal of A1C reduction and TIR improvements, suggesting that continued CGM use achieves the greatest benefits (15).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [15] Aleppo, 2021, The effect of discontinuing continuous glucose monitoring in adults with type 2 diabetes treated with basal insulin, Diabetes Care source
Not checked in the free run.
May combine two claims.
Premisecitation§ Data From Randomized Controlled TrialsOne study in youth with type 1 diabetes did not show a reduction in A1C, but the device was well received and was associated with increased testing frequency and improved diabetes treatment satisfaction.
“One study in youth with type 1 diabetes did not show a reduction in A1C levels (72); however, the device was well received and was associated with an increased frequency of testing and improved diabetes treatment satisfaction (72).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [72] Boucher, 2020, Effect of 6 months of flash glucose monitoring in youth with type 1 diabetes and high-risk glycemic control: a randomized controlled trial, Diabetes Care source
Not checked in the free run.
May combine two claims.
Premisecitation§ Data From Randomized Controlled TrialsrtCGM benefits were reported in a mixed population of adults with type 2 diabetes, including people not using insulin, with reduction in A1C, increase in TIR, and reduction of time in hyperglycemia.
“In addition, rtCGM benefits were reported in a mixed population (including people not using insulin) of adults with type 2 diabetes with reduction in A1C levels, increase in TIR, and reduction of time in hyperglycemia (>180 mg/dL [>10 mmol/L] and >250 mg/dL [>13.9 mmol/L]) (10).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [10] Grace, 2022, Use of real-time continuous glucose monitoring improves glycemic control and other clinical outcomes in type 2 diabetes patients treated with less intensive therapy, Diabetes Technol Ther source
Not checked in the free run.
May combine two claims.
Premisecitation§ Data From Randomized Controlled TrialsShort-term rtCGM use in youth with type 2 diabetes did not impact short-term glucose changes or A1C improvement, but users reported behavioral changes including increased blood glucose measurements, increased insulin administration, and improved diabetes management and quality of life.
“Although short-term use of rtCGM in youth with type 2 diabetes did not impact short-term glucose changes or A1C improvement, users reported behavioral changes with increased blood glucose measurements, increased insulin administration, and overall improved diabetes management and quality of life (64,65).”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [64] Manfredo, 2023, Short-term use of CGM in youth onset type 2 diabetes is associated with behavioral modifications, Front Endocrinol (Lausanne) source
Not checked in the free run.
- cites [65] Chesser, 2024, Real-time continuous glucose monitoring in adolescents and young adults with type 2 diabetes can improve quality of life, J Diabetes Sci Technol source
Not checked in the free run.
May combine two claims.
Premisecitation§ Data From Randomized Controlled TrialsIn a post hoc analysis, isCGM effects were present 1 week after initiation for weekly mean glucose, GMI, TIR, TAR, and mean amplitude glucose excursion, and remained stable from baseline to 12 weeks.
“In a subsequent post hoc analysis, the isCGM group showed that the effects of isCGM were present 1 week after isCGM initiation for weekly mean glucose, glucose management indicator (GMI), percentage of TIR, percentage of TAR, and mean amplitude glucose excursion and remained stable from baseline to 12 weeks (74).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [74] Hayase, 2023, Improved glycemic control after the use of flash glucose monitoring accompanied by improved treatment satisfaction in patients with non-insulin-treated type 2 diabetes: a post-hoc analysis of a randomized controlled trial, Prim Care Diabetes source
Not checked in the free run.
May combine two claims.
Premisecitation§ Observational and Real-world StudiesIn adults with type 2 diabetes treated with basal insulin or noninsulin therapy, initiation of intermittently scanned CGM reduces acute diabetes events and all-cause inpatient hospitalizations at 6 months.
“Similar reductions of acute diabetes events and all-cause inpatient hospitalizations were seen in a retrospective review of adults with type 2 diabetes treated with basal insulin or with noninsulin therapy 6 months after initiation of isCGM (82).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [82] Miller, 2021, Flash CGM associated with event reduction in nonintensive diabetes therapy, Am J Manag Care source
Not checked in the free run.
May combine two claims.
Premisecitation§ Observational and Real-world StudiesIn adults with type 2 diabetes not treated with insulin, real-time CGM use at 6 and 12 months versus baseline reduces mean glucose and GMI, increases time in range and time in tight target range 70-140 mg/dL, and reduces time above range >180 and >250 mg/dL.
“In this study, rtCGM benefits were observed at 6 month and 12 months versus baseline, with reduction of mean glucose levels, reduction of GMI, increase in TIR, increase in time in tight target range (70-140 mg/dL [3.9-7.8 mmol/L]), and reduction in TAR >180 and >250 mg/dL (88).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [88] Layne, 2024, Long-term improvements in glycemic control with Dexcom CGM use in adults with noninsulin-treated type 2 diabetes, Diabetes Technol Ther. source
Not checked in the free run.
May combine two claims.
Premisecitation§ Observational and Real-world StudiesIn adults with type 1 or type 2 diabetes treated with insulin, real-time CGM significantly lowers A1C and reduces emergency department visits or hospitalizations for hypoglycemia, but does not significantly lower overall rates of emergency department visits, hospitalizations, or hyperglycemia.
“Retrospective data from rtCGM use in adults (87) with type 1 or type 2 diabetes treated with insulin showed that the use of rtCGM significantly lowered A1C levels and reduced rates of emergency department visits or hospitalizations for hypoglycemia but did not significantly lower overall rates of emergency department visits, hospitalizations, or hyperglycemia.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [87] Karter, 2021, Association of real-time continuous glucose monitoring with glycemic control and acute metabolic events among patients with insulin-treated diabetes, JAMA source
Not checked in the free run.
May combine two claims.
Premisecitation§ Observational and Real-world StudiesIn adults with nonintensively treated type 2 diabetes, continued use of intermittently scanned CGM reduces A1C and GMI, increases time in range, and reduces time above range >180 mg/dL.
“Finally, a retrospective study of continued use of isCGM in adults with nonintensively treated type 2 diabetes showed reduction of A1C and GMI, increase in TIR, and reduction of TAR (>180 mg/dL) (86).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [86] Al Hayek, 2023, Use of flash glucose monitoring and glycemic control in patients with type 2 diabetes mellitus not treated with an intensive insulin regimen: 1-year real-life retrospective cohort study, Adv Ther source
Not checked in the free run.
May combine two claims.
Premisecitation§ Observational and Real-world StudiesIn youth with type 1 diabetes, intermittently scanned CGM is associated with a slight increase in A1C and weight but a high user satisfaction rate.
“In an observational study in youth with type 1 diabetes, a slight increase in A1C levels and weight was seen, but the device was associated with a high user satisfaction rate (76).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [76] Charleer, 2020, Intermittently scanned continuous glucose monitoring is associated with high satisfaction but increased HbA1c and weight in well-controlled youth with type 1 diabetes, Pediatr Diabetes source
Not checked in the free run.
May combine two claims.
Premisecitation§ Observational and Real-world StudiesIn adults with type 1 or type 2 diabetes, intermittently scanned CGM reduces acute diabetes complications such as diabetic ketoacidosis, severe hypoglycemia or diabetes-related coma, and hospitalizations for hypoglycemia and hyperglycemia.
“Reductions in acute diabetes complications, such as diabetic ketoacidosis (DKA), episodes of severe hypoglycemia or diabetes-related coma, and hospitalizations for hypoglycemia and hyperglycemia, have been observed in adults with type 1 or type 2 diabetes (43,78,80)”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [43] Hohendorff, 2021, Intermittently scanned continuous glucose monitoring data of polish patients from real-life conditions: more scanning and better glycemic control compared to worldwide data, Diabetes Technol Ther source
Not checked in the free run.
- cites [78] Nathanson, 2021, Effect of flash glucose monitoring in adults with type 1 diabetes: a nationwide, longitudinal observational study of 14,372 flash users compared with 7691 glucose sensor naive controls, Diabetologia source
Not checked in the free run.
- cites [80] Roussel, 2021, Important drop in rate of acute diabetes complications in people with type 1 or type 2 diabetes after initiation of flash glucose monitoring in France: the RELIEF study, Diabetes Care source
Not checked in the free run.
May combine two claims.
Premisecitation§ Use of Professional Continuous Glucose Monitoring and Intermittent Use of Continuous Glucose MonitoringIn a real-world study, professional CGM in individuals with type 2 diabetes not on insulin at baseline and at 6 months resulted in lower A1C at 6 months and a shift toward greater use of glucose-lowering medications with cardiometabolic benefits.
“Furthermore, in a real-world study, the use of professional CGM in individuals with type 2 diabetes not on insulin at baseline and at 6 months of followup resulted in lower A1C at 6 months as well as a shift toward greater use of glucose-lowering medications with cardiometabolic benefits, such as sodiumglucose transporter 2 inhibitors and glucagon-like peptide 1 receptor agonists (113).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [113] Nemlekar, 2023, Association between change in A1C and use of professional continuous glucose monitoring in adults with type 2 diabetes on noninsulin therapies: a real-world evidence study, Clin Diabetes source
Not checked in the free run.
May combine two claims.
Premisecitation§ Use of Professional Continuous Glucose Monitoring and Intermittent Use of Continuous Glucose MonitoringProfessional CGM devices provide retrospective data, either blinded or unblinded, for analysis and can be used to identify patterns of hypoglycemia and hyperglycemia.
“Professional CGM devices, which provide retrospective data, either blinded or unblinded, for analysis can be used to identify patterns of hypoglycemia and hyperglycemia (111,112).”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [111] Ajjan, 2019, Reduction in HbA1c using professional flash glucose monitoring in insulin-treated type 2 diabetes patients managed in primary and secondary care settings: a pilot, multicentre, randomised controlled trial, Diab Vasc Dis Res source
Not checked in the free run.
- cites [112] Ribeiro, 2021, Impact of blinded retrospective continuous glucose monitoring on clinical decision making and glycemic control in persons with type 2 diabetes on insulin therapy, Nutr Metab Cardiovasc Dis source
Not checked in the free run.
May combine two claims.
Premisecitation§ Data AnalysisCGM is essential for creating an ambulatory glucose profile and providing data on time in range, percentage of time above and below range, and glycemic variability.
“CGM is essential for creating an ambulatory glucose profile (AGP) and providing data on TIR, percentage of time spent above and below range, and glycemic variability (94).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [94] Battelino, 2019, Clinical targets for continuous glucose monitoring data interpretation: recommendations from the International Consensus on Time in Range, Diabetes Care source
Not checked in the free run.
May combine two claims.
Premisecitation§ Real-time Continuous Glucose Monitoring Device Use in PregnancyIn pregnant adults with type 1 diabetes on multiple daily injections or insulin pump therapy, real-time CGM in addition to standard care reduces A1C levels, increases pregnancy-specific time in range 63-140 mg/dL, reduces time in hyperglycemia, and reduces large-for-gestational-age births, infant hospital length of stay, and severe neonatal hypoglycemia without increasing hypoglycemia.
“Prior data from one well-designed RCT showed a reduction in A1C levels in pregnant adults with type 1 diabetes on MDI or insulin pump therapy and using rtCGM in addition to standard care; CGM users experienced more pregnancy-specific TIR (63-140 mg/dL [3.5-7.8 mmol/L]) and less time in hyperglycemia (103).”
- Also stated in: § Real-time Continuous Glucose Monitoring Device Use in Pregnancy · boosted
“This study demonstrated the value of rtCGM in pregnancy complicated by type 1 diabetes by showing a mild improvement in A1C levels and a significant improvement in the maternal glucose TIR for pregnancy (63-140 mg/dL [3.5-7.8 mmol/L]), without an increase in hypoglycemia, as well as reductions in large-for-gestational-age births, infant hospital length of stay, and severe neonatal hypoglycemia (”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [103] Feig, 2017, Continuous glucose monitoring in pregnant women with type 1 diabetes (CONCEPTT): a multicentre international randomised controlled trial, Lancet source
Not checked in the free run.
- Also stated in: § Real-time Continuous Glucose Monitoring Device Use in Pregnancy · boosted
May combine two claims.
Premisecitation§ Real-time Continuous Glucose Monitoring Compared With Intermittently Scanned Continuous Glucose MonitoringIn a 12-month real-world nonrandomized study in adults with type 1 diabetes, at 12 months A1C, time in level 1 hypoglycemia (<70 mg/dL), and time in level 2 hypoglycemia (<54 mg/dL) were lower in the real-time CGM group than in the intermittently scanned CGM group, and time in range was higher in the real-time CGM group.
“At 12 months, A1C levels, time in level 1 hypoglycemia (<70 mg/dL [<3.9 mmol/L]), and time in level 2 hypoglycemia (<54 mg/dL [<3.0 mmol/L]) were all lower in the rtCGM group than in the isCGM group; similarly, the TIR was higher in the rtCGM group than in the isCGM group (92).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [92] Radovnická, 2022, Lower glycated hemoglobin with real-time continuous glucose monitoring than with intermittently scanned continuous glucose monitoring after 1 year: the CORRIDA LIFE study, Diabetes Technol Ther source
Not checked in the free run.
May combine two claims.
Premisecitation§ Insulin PumpsAdoption of pump therapy in the U.S. shows geographical variations, which may be related to health care professional preference or center characteristics and socioeconomic status, as pump therapy is more common in individuals of higher socioeconomic status.
“Adoption of pump therapy in the U.S. shows geographical variations, which may be related to health care professional preference or center characteristics (165,166) and socioeconomic status, as pump therapy is more common in individuals of higher socioeconomic status, as reflected by private health insurance, family income, and education (165,166).”
Quote in the paperNot a substantial claim0 of 2 sources checked- cites [165] Lin, 2013, Race, socioeconomic status, and treatment center are associated with insulin pump therapy in youth in the first year following diagnosis of type 1 diabetes, Diabetes Technol Ther source
Not checked in the free run.
- cites [166] Willi, 2015, Racial-ethnic disparities in management and outcomes among children with type 1 diabetes, Pediatrics source
Not checked in the free run.
May combine two claims.
Premisecitation§ Insulin PumpsA systematic review and meta-analysis concluded that pump therapy has modest advantages for lowering A1C levels (−0.30% [95% CI −0.58 to −0.02]) and for reducing severe hypoglycemia rates in children and adults.
“However, a systematic review and meta-analysis concluded that pump therapy has modest advantages for lowering A1C levels (À0.30% [95% CI À0.58 to À0.02]) and for reducing severe hypoglycemia rates in children and adults (163).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [163] Yeh, 2012, Comparative effectiveness and safety of methods of insulin delivery and glucose monitoring for diabetes mellitus: a systematic review and meta-analysis, Ann Intern Med source
Not checked in the free run.
May combine two claims.
Premisecitation§ INSULIN PUMPS AND AUTOMATED INSULIN DELIVERY SYSTEMS,Connected insulin pens and pen caps are useful to people with diabetes for real-time insulin dosing and allow clinicians to retrospectively review insulin delivery times and, in some cases, doses and glucose data to make informed insulin dose adjustments.
“These pens and pen caps are useful to people with diabetes for realtime insulin dosing and allow clinicians to retrospectively review the insulin delivery times and, in some cases, doses and glucose data to make informed insulin dose adjustments (153).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [153] Seo, 2023, Patients' preferences for connected insulin pens: a discrete choice experiment among patients with type 1 and type 2 diabetes, Patient source
Not checked in the free run.
May combine two claims.
Premisecitation§ Insulin PumpsReal-world data on insulin pump use in individuals with type 1 diabetes show benefits in A1C levels and hypoglycemia reductions as well as total daily insulin dose reduction.
“Real-world data on insulin pump use in individuals with type 1 diabetes show benefits in A1C levels and hypoglycemia reductions as well as total daily insulin dose reduction (164).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [164] Aleppo, 2023, Improvements in glycemic outcomes in 4738 children, adolescents, and adults with type 1 diabetes initiating a tubeless insulin management system, Diabetes Ther source
Not checked in the free run.
May combine two claims.
Premisecitation§ INSULIN PUMPS AND AUTOMATED INSULIN DELIVERY SYSTEMS,In a multicenter randomized controlled trial in people with type 1 diabetes, use of an insulin pen cap was associated with improved glycemic outcomes at 6 weeks, with an increase in time in range and a decrease in GMI and time above range.
“In a multicenter RCT in people with type 1 diabetes, the use of an insulin pen cap was associated with improved glycemic outcomes at 6 weeks in the insulin cap group, with an increase in TIR and decrease in GMI and TAR (154).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [154] Gomez-Peralta, 2023, Efficacy of a connected insulin pen cap in people with noncontrolled type 1 diabetes: a multicenter randomized clinical trial, Diabetes Care source
Not checked in the free run.
May combine two claims.
Premisecitation§ INSULIN PUMPS AND AUTOMATED INSULIN DELIVERY SYSTEMS,In a recent real-world study with multinational data from 3,954 adults with diabetes using a connected pen and CGM, treatment engagement with a connected insulin pen is positively associated with glycemic outcomes, and missing as little as two basal doses or four bolus insulin doses over a 14-day period is associated with a clinically relevant decrease in time in range of ≥5%.
“A recent realworld study with multinational data collected from 3,954 adults with diabetes using a connected pen and CGM validated the fact that treatment engagement with a connected insulin pen is positively associated with glycemic outcomes.”
- Also stated in: § INSULIN PUMPS AND AUTOMATED INSULIN DELIVERY SYSTEMS, · hedged
“On the other hand, missing as little as two basal doses or four bolus insulin doses over a 14-day period would be associated with a clinically relevant decrease in TIR of $5% (156).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [156] Danne, 2024, Association between treatment adherence and continuous glucose monitoring outcomes in people with diabetes using smart insulin pens in a real-world setting, Diabetes Care source
Not checked in the free run.
- Also stated in: § INSULIN PUMPS AND AUTOMATED INSULIN DELIVERY SYSTEMS, · hedged
May combine two claims.
Premisecitation§ Insulin PumpsCurrent reasons for pump therapy attrition are problems with cost or wearability, loss of insurance, dislike of the pump, suboptimal glycemic outcomes, or mood disorders.
“Current reasons for attrition are problems with cost or wearability, loss of insurance, dislike of the pump, suboptimal glycemic outcomes, or mood disorders (e.g., anxiety or depression) (175).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [175] Wong, 2015, Insulin pump use and glycemic control in adolescents with type 1 diabetes: predictors of change in method of insulin delivery across two years, Pediatr Diabetes source
Not checked in the free run.
Classified as probably not a substantial claim.
Premisecitation§ Insulin Pumps in YouthPump therapy may be the preferred mode of insulin delivery for children under 7 years of age.
“In particular, pump therapy may be the preferred mode of insulin delivery for children under 7 years of age (188).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [188] Sundberg, 2017, ISPAD Guidelines. Managing diabetes in preschool children, Pediatr Diabetes source
Not checked in the free run.
May combine two claims.
Premisecitation§ Insulin Pumps in YouthEvidence suggests insulin pump therapy may reduce diabetic ketoacidosis risk and diabetes complications, particularly retinopathy and peripheral neuropathy in youth, compared with multiple daily injections.
“There is also evidence that insulin pump therapy may reduce DKA risk (182,186) and diabetes complications, particularly retinopathy and peripheral neuropathy in youth, compared with MDI (169).”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [169] Peters, 2016, Diabetes technology-continuous subcutaneous insulin infusion therapy and continuous glucose monitoring in adults: an Endocrine Society clinical practice guideline, J Clin Endocrinol Metab source
Not checked in the free run.
- cites [182] Karges, 2017, Association of insulin pump therapy vs insulin injection therapy with severe hypoglycemia, ketoacidosis, and glycemic control among children, adolescents, and young adults with type 1 diabetes, JAMA source
Not checked in the free run.
- cites [186] Maahs, 2015, Rates of diabetic ketoacidosis: international comparison with 49,859 pediatric patients with type 1 diabetes from England, Wales, the U.S., Austria, and Germany, Diabetes Care source
Not checked in the free run.
May combine two claims.
Premisecitation§ Automated Insulin Delivery Systems in PregnancyRecent data show clinical benefits and safety of AID use in pregnancy, though only one study used an AID system with a pregnancy-specific glycemic target.
“Recent data have shown the clinical benefits and safety of AID use, even though only one study used an AID system with a pregnancyspecific glycemic target.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [236] Lee, 2023, Automated insulin delivery in women with pregnancy complicated by type 1 diabetes, N Engl J Med source
Not checked in the free run.
- Rests on an assumption: Current FDA-approved AID systems, except one approved but not commercially available, have glucose goals not pregnancy-specific and algorithms not designed for pregnancy-specific goals.
May combine two claims.
Premisecitation§ Data From Real-world StudiesReal-world studies analyzed longer duration of AID use than pivotal trials, mostly >6 months, average 9 months.
“Newer systems have shown increased time spent in automation, and the real-world studies have retrospectively analyzed longer duration of system use compared with their respective pivotal trials, with most analyses occurring for more than 6 months and an average duration of 9 months (227).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [227] Considine, 2024, Real-world evidence of automated insulin delivery system use, Diabetes Technol Ther source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.
Study design and conductcitation§ Data From Real-world StudiesFor some AID systems, all data are automatically collected to a database; for others, data are collected by voluntary sharing.
“It is important to emphasize that for some AID systems all data are automatically collected to the database (228), whereas for other systems data are collected based on voluntary sharing to the database by AID users.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [228] Forlenza, 2024, Real-world evidence of Omnipod 5 automated insulin delivery system use in 69,902 people with type 1 diabetes, Diabetes Technol Ther source
Not checked in the free run.
May combine two claims.
Premisecitation§ Data From Real-world StudiesA recent systematic review of 20 AID real-world studies covering 171,209 individuals substantiated pivotal trial results and confirmed clinical benefits of AID in type 1 diabetes.
“A recent systematic review of AID real-world studies, with 20 studies representing 171,209 individuals, substantiated the results observed in the pivotal trials and have confirmed the clinical benefits of AID systems in people with type 1 diabetes.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [227] Considine, 2024, Real-world evidence of automated insulin delivery system use, Diabetes Technol Ther source
Not checked in the free run.
May combine two claims.
Premisecitation§ Data From Real-world StudiesReal-world AID benefits include improvement in A1C, TIR, other glucometrics, and psychosocial benefits.
“Benefits include improvement in A1C levels, TIR, and other glucometrics as well as psychosocial benefits (229)(230)(231)(232)(233)(234).”
Quote in the paperSubstantial claim0 of 3 sources checked- cites [229] Amigó, 2023, Switching from treatment with sensor augmented pump to hybrid closed loop system in type 1 diabetes: impact on glycemic control and neuropsychological tests in the real world, Diabetes Res Clin Pract source
Not checked in the free run.
- cites [230] Chico, 2023, Efficacy, safety, and satisfaction with the Accu-Chek Insight with Diabeloop closed-loop system in subjects with type 1 diabetes: a multicenter real-world study, Diabetes Technol Ther source
Not checked in the free run.
- cites [231] Benhamou, 2023, One-year real-world performance of the DBLG1 closed-loop system: data from 3706 adult users with type 1 diabetes in Germany, Diabetes Obes Metab source
Not checked in the free run.
May combine two claims.
Premisecitation§ Automated Insulin Delivery Systems in PregnancyIn that trial, there were no differences in preterm births, birth weight, neonatal complications, or NICU admission.
“There were no differences in the number of preterm births, birth weight, neonatal complications, or admission to the neonatal intensive care unit.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [236] Lee, 2023, Automated insulin delivery in women with pregnancy complicated by type 1 diabetes, N Engl J Med source
Not checked in the free run.
- Rests on an assumption: Current FDA-approved AID systems, except one approved but not commercially available, have glucose goals not pregnancy-specific and algorithms not designed for pregnancy-specific goals.
May combine two claims.
Premisecitation§ Insulin Pumps and Automated Insulin Delivery Systems in People With Type 2 and Other Types of DiabetesReal-world reports show reduction of A1C and total daily insulin dose in type 2 diabetes initiating insulin pump therapy.
“More recently, real-world reports have shown reduction of A1C levels and reduction of total daily insulin dose in individuals with type 2 diabetes initiating insulin pump therapy (247).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [247] Carlson, 2021, Improved glycemic control in 3,592 adults with type 2 diabetes mellitus initiating a tubeless insulin management system, Diabetes Res Clin Pract source
Not checked in the free run.
May combine two claims.
Premisecitation§ Automated Insulin Delivery Systems in PregnancyIn that study, time below range was lower over 24 h and overnight in the AID group.
“Time spent below range was lower over 24 h and overnight in the AID group as well.”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [239] Benhalima, 2024, Comparing advanced hybrid closed loop therapy and standard insulin therapy in pregnant women with type 1 diabetes (CRISTAL): a parallel-group, open-label, randomised controlled trial, Lancet Diabetes Endocrinol source
Not checked in the free run.
- Rests on an assumption: Current FDA-approved AID systems, except one approved but not commercially available, have glucose goals not pregnancy-specific and algorithms not designed for pregnancy-specific goals.
May combine two claims.
Premisecitation§ Insulin Pumps and Automated Insulin Delivery Systems in People With Type 2 and Other Types of DiabetesInsulin pump use in insulin-requiring people with any type of diabetes may improve user satisfaction and simplify therapy.
“Use of insulin pumps in insulin-requiring people with any type of diabetes may improve user satisfaction and simplify therapy (171,241).”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [171] Vigersky, 2018, Improved HBa1c, total daily insulin dose, and treatment satisfaction with insulin pump therapy compared to multiple daily insulin injections in patients with type 2 diabetes irrespective of baseline c-peptide levels, Endocr Pract source
Not checked in the free run.
- cites [241] Grunberger, 2020, Treatment intensification with insulin pumps and other technologies in patients with type 2 diabetes: results of a physician survey in the United States, Clin Diabetes source
Not checked in the free run.
May combine two claims.
Premisecitation§ Automated Insulin Delivery Systems in PregnancyIn that pilot RCT, safety and adverse pregnancy outcomes were similar between groups.
“Time at <63 mg/dL was lower in the hybrid closed-loop group, whereas percentage of the pregnancy-specific TIR was greater in the SAP group in the third trimester, with similar safety and adverse pregnancy outcomes between groups (237).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [237] Polsky, 2024, Randomized trial of assisted hybrid closed-loop therapy versus sensor-augmented pump therapy in pregnancy, Diabetes Technol Ther source
Not checked in the free run.
- Rests on an assumption: Current FDA-approved AID systems, except one approved but not commercially available, have glucose goals not pregnancy-specific and algorithms not designed for pregnancy-specific goals.
Classified as probably not a substantial claim.
Interpretationreasoning§ Digital Health TechnologySpecific diabetes apps cannot be recommended without RCTs and validation unless they have FDA clearance, because data are insufficient.
“There are insufficient data to provide recommendations for specific apps for diabetes management, education, and support in the absence of RCTs and validation of apps unless they are FDA cleared.”
Quote in the paperSubstantial claimMay combine two claims.
Premisecitation§ Open-Source Automated Insulin DosingThe code for these algorithms was not authored by any single person, and many users do not compile the software themselves.
“No individual person has written all the code for these algorithms, and a large percentage of users do not build the software themselves (255).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [255] Lum, 2021, A real-world prospective study of the safety and effectiveness of the loop open source automated insulin delivery system, Diabetes Technol Ther source
Not checked in the free run.
- Rests on an assumption: OS-AID algorithms are largely designed, maintained, and curated by people with diabetes and their loved ones.
May combine two claims.
Premisecitation§ Open-Source Automated Insulin DosingThe OpenAPS heuristic algorithm is supported by large real-world studies and a multicenter RCT.
“The OpenAPS heuristic algorithm (implemented on a system on a chip in OpenAPS, Android smartphones as An-droidAPS, and iPhone as iAPS/Trio) is supported by large real-world studies (256) and a multicenter RCT (257).”
Quote in the paperSubstantial claim0 of 2 sources checked- cites [256] Braune, 2021, Why #WeAreNotWaiting–motivations and self-reported outcomes among users of open-source automated insulin delivery systems: multinational survey, J Med Internet Res source
Not checked in the free run.
- cites [257] Burnside, 2022, Open-source automated insulin delivery in type 1 diabetes, N Engl J Med source
Not checked in the free run.
- Rests on an assumption: There are two main available algorithms, Open-APS and Loop, implemented on a variety of platforms.
- Rests on an assumption: The OpenAPS algorithm is the only AID system to support unannounced meals.
Probably not a substantial claim: may not pass S3 (load-bearing).
Premisecitation§ Digital Health TechnologyMany online programs offer lifestyle counseling to achieve weight loss and increased physical activity.
“Many online programs offer lifestyle counseling to achieve weight loss and increased physical activity (263).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [263] Chao, 2019, Enhanced self-efficacy and behavioral changes among patients with diabetes: cloud-based mobile health platform and mobile app service, JMIR Diabetes source
Not checked in the free run.
May combine two claims.
Premisecitation§ Digital Health TechnologyEstablished cloud-based data aggregator programs such as Tidepool and Glooko have appropriate data security features and are HIPAA compliant.
“Established cloud-based data aggregator programs, such as Tidepool, Glooko, and others, have been developed with appropriate data security features and are compliant with the U.S. Health Insurance Portability and Accountability Act of 1996.”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [262] Wong, 2018, A pilot study of use of a software platform for the collection, integration, and visualization of diabetes device data by health care providers in a multidisciplinary pediatric setting, Diabetes Technol Ther source
Not checked in the free run.
May combine two claims.
Premisecitation§ Digital Health TechnologyA real-world observational study in type 2 diabetes patients on basal insulin, oral agents, or no glucose-lowering drugs found that a digital health solution plus rtCGM lowered GMI and TAR above 180 and 250 mg/dL, raised TIR by 15%, and increased weekly engagement.
“However, in a real-world observational study in individuals with type 2 diabetes treated with basal insulin, oral medications, or no medications, the use of a digital health solution and rtCGM resulted in reductions of GMI and TAR >180 and >250 mg/dL as well as an increase in TIR by 15% and participation in a least one engagement activity per week (274).”
Quote in the paperSubstantial claim0 of 1 sources checked- cites [274] Kumbara, 2023, Impact of a combined continuous glucose monitoring-digital health solution on glucose metrics and self-management behavior for adults with type 2 diabetes: real-world, observational study, JMIR Diabetes source
Not checked in the free run.
May combine two claims.
Interpretationnone given§ Digital Health TechnologyThere are limited RCT data for many digital health interventions, and long-term follow-up is lacking.
“There are limited RCT data for many of these interventions, and long-term follow-up is lacking.”
Quote in the paperSubstantial claimMay combine two claims.
Premisecitation§ Digital Health TechnologyThese cloud-based programs can help monitor people with diabetes and provide access to their health care teams.
“These programs can help monitor people with diabetes and provide access to their health care teams (262).”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites [262] Wong, 2018, A pilot study of use of a software platform for the collection, integration, and visualization of diabetes device data by health care providers in a multidisciplinary pediatric setting, Diabetes Technol Ther source
Not checked in the free run.
May combine two claims.
Premisecitation§ Inpatient CareThis approach was taken to reduce PPE use and more closely monitor patients so health care personnel do not have to enter a patient room solely to measure glucose.
“This approach has been taken to reduce the use of personal protective equipment and more closely monitor patients so that health care personnel do not have to go into a patient room solely to measure a glucose level (283-286).”
Quote in the paperSubstantial claim0 of 4 sources checked- cites [283] Davis, 2021, Remote continuous glucose monitoring with a computerized insulin infusion protocol for critically ill patients in a COVID-19 medical ICU: proof of concept, Diabetes Care source
Not checked in the free run.
- cites [284] Sadhu, 2020, Continuous glucose monitoring in critically ill patients with COVID-19: results of an emergent pilot study, J Diabetes Sci Technol source
Not checked in the free run.
- cites [285] Agarwal, 2021, Continuous glucose monitoring in the intensive care unit during the COVID-19 pandemic, Diabetes Care source
Not checked in the free run.
- cites [286] Galindo, 2020, Implementation of continuous glucose monitoring in the hospital: emergent considerations for remote glucose monitoring during the COVID-19 pandemic, J Diabetes Sci Technol source
Not checked in the free run.
Probably not a substantial claim: may not pass S3 (load-bearing).
Premisenone given§ Inpatient CareGalactose produces falsely elevated blood glucose readings on glucose meters.
“Galactose | Falsely higher blood glucose values”
Quote in the paperNot a substantial claimMay combine two claims.
Premisecitation§ Inpatient CareISO 15197:2013 requires that 95% of blood glucose meter measurements fall within 15% of the reference value when glucose is at least 100 mg/dL, and within 15 mg/dL when glucose is below 100 mg/dL.
“95% within 15% for BG $100 mg/dL”
- Also stated in: § Inpatient Care · plain
“95% within 15 mg/dL for BG <100 mg/dL”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites ISO 15197:2013
Not checked in the free run.
- Also stated in: § Inpatient Care · plain
May combine two claims.
Premisecitation§ Inpatient CareThe FDA accuracy standard for blood glucose meters requires that 95% of measurements fall within 12% of the reference value when glucose is at least 75 mg/dL, and within 12 mg/dL when glucose is below 75 mg/dL.
“95% within 12% for BG $75 mg/dL”
- Also stated in: § Inpatient Care · plain
“95% within 12 mg/dL for BG <75 mg/dL”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites FDA
Not checked in the free run.
- Also stated in: § Inpatient Care · plain
May combine two claims.
Premisecitation§ Inpatient CareThe FDA accuracy standard for blood glucose meters requires that 98% of measurements fall within 15% of the reference value when glucose is at least 75 mg/dL, and within 15 mg/dL when glucose is below 75 mg/dL.
“98% within 15% for BG $75 mg/dL”
- Also stated in: § Inpatient Care · plain
“98% within 15 mg/dL for BG <75 mg/dL”
Quote in the paperNot a substantial claim0 of 1 sources checked- cites FDA
Not checked in the free run.
- Also stated in: § Inpatient Care · plain
Probably not a substantial claim: may not pass S3 (load-bearing).
Premisenone given§ Inpatient CareXylose produces falsely elevated blood glucose readings on glucose meters.
“Xylose | Falsely higher blood glucose values”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Premisenone given§ Inpatient CareA high hematocrit produces falsely reduced blood glucose readings.
“Hematocrit (high) | Falsely lower blood glucose values”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Premisenone given§ Inpatient CareVitamin C produces falsely reduced or falsely elevated blood glucose readings.
“Vitamin C | Falsely lower or higher blood glucose values”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Premisenone given§ Inpatient CareAcetaminophen produces falsely elevated blood glucose readings at low blood glucose levels.
“Acetaminophen | Falsely higher blood glucose values at low blood glucose levels”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Premisenone given§ Inpatient CareA low hematocrit produces falsely elevated blood glucose readings.
“Hematocrit (low) | Falsely higher blood glucose values”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Premisenone given§ Inpatient CareUric acid produces falsely elevated blood glucose readings at very low or very high glucose levels.
“Uric acid | Falsely higher blood glucose values at very low or”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Premisenone given§ Inpatient CareDopamine produces falsely elevated blood glucose readings at low blood glucose levels.
“Dopamine | Falsely higher blood glucose values at low blood glucose levels”
Quote in the paperNot a substantial claimProbably not a substantial claim: may not pass S3 (load-bearing).
Premisenone given§ Inpatient CareFurosemide produces falsely reduced blood glucose readings.
“Furosemide | Falsely lower blood glucose values”
Quote in the paperNot a substantial claim
The paper relies on this without support.
Diabetes technology, when combined with education, follow-up, pharmacotherapy if needed, and support, can improve the lives and health of people with diabetes.
“Diabetes technology, coupled with education, follow-up, pharmacotherapy if needed, and support, can improve the lives and health of people with diabetes; however, the complexity and rapid evolution of the diabetes technology landscape can also be a barrier to implementation for people with diabetes, their care partners, and the health care team.”
The paper relies on this without support.
No device used in diabetes management works optimally without education, training, and ongoing support.
“In general, no device used in diabetes management works optimally without education, training, and ongoing support.”
The paper relies on this without support.
Better outcomes cannot be achieved without training and education of health care professionals.
“Better outcomes cannot be achieved, however, without the training and education of health care professionals.”
The paper relies on this without support.
Preowned or secondhand glucose test strips may give incorrect results.
“People with diabetes should be advised against purchasing or reselling preowned or secondhand test strips, as these may give incorrect results.”
The paper relies on this without support.
CGM measures interstitial glucose, which correlates well with plasma glucose, although it can lag when glucose levels are rising or falling rapidly.
“CGM measures interstitial glucose (which correlates well with plasma glucose, although at times, it can lag if glucose levels are rising or falling rapidly).”
The paper relies on this without support.
Current FDA-approved AID systems, except one approved but not commercially available, have glucose goals not pregnancy-specific and algorithms not designed for pregnancy-specific goals.
“The use of AID systems in diabetes and pregnancy presents particular challenges, as the current FDA-approved AID systems (except for one that has been FDA approved but is not yet commercially available) have glucose goals that are not pregnancy specific and do not have algorithms designed to achieve pregnancyspecific glucose goals.”
The paper relies on this without support.
Use of insulin pumps and AID systems in type 2 diabetes is still limited, and only one system is FDA approved for type 2 diabetes.
“The use of insulin pumps and AID systems in type 2 diabetes is still limited, and at this time only one system is FDA approved for use in type 2 diabetes.”
The paper relies on this without support.
OS-AID algorithms are largely designed, maintained, and curated by people with diabetes and their loved ones.
“OS-AID algorithms are largely designed, maintained, and curated by people with diabetes and their loved ones.”
The paper relies on this without support.
Thousands of people with diabetes use these algorithms with cleared CGM systems and insulin pump components.
“Thousands of people with diabetes use these algorithms with cleared CGM systems and insulin pump components.”
The paper relies on this without support.
There are two main available algorithms, Open-APS and Loop, implemented on a variety of platforms.
“There are two main available algorithms, the Open-APS algorithm and the Loop algorithm, which have been implemented on a variety of platforms.”
The paper relies on this without support.
The OpenAPS algorithm is the only AID system to support unannounced meals.
“The OpenAPS algorithm is the only AID system to support unannounced meals.”
The paper relies on this without support.
Loop is an open-source model predictive control algorithm implemented on iPhones as an app.
“Loop, an open-source model predictive control algorithm, is implemented on iPhones as an app.”
The paper relies on this without support.
Both Loop and OpenAPS algorithms offer direct management of algorithm aggressiveness through conventional pump settings.
“Both the Loop and OpenAPS algorithms offer direct management of algorithm aggressiveness through conventional pump settings.”
The paper relies on this without support.
Many online programs include a health coach and can create small groups of similar participants on social networks.
“Many include a health coach and can create small groups of similar participants on social networks.”
The paper relies on this without support.
Point-of-care BGM remains the approved method for glucose monitoring in hospitals, especially for dosing insulin and treating hypoglycemia.
“Pointof-care BGM remains the approved method for glucose monitoring in hospitals, especially for dosing insulin and treating hypoglycemia.”
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
With the advent of newer studies of CGM in noninsulin-treated individuals and increasing uptake, the utility of CGM is progressively being endorsed in this population.
“With the advent of newer studies of CGM in noninsulin‐treated individuals and increasing uptake, the utility of CGM is progressively being endorsed in this population.”
From Continuous glucose monitoring in noninsulin‐treated type 2 diabetes: A critical review of reported trials with an updated systematic review and meta‐analysis of randomised controlled trials (2025) · cites this paper as [4]
Recommendation 7.16 (Continuous Glucose Monitoring Devices; page unavailable) advises considering CGM for adults with type 2 diabetes using noninsulin glucose-lowering medication, and Data From Randomized Controlled Trials reports benefits in adults not using insulin. These passages support the claim that CGM’s utility is being endorsed for this population. The copy describes CGM as widely available but does not establish increasing uptake among noninsulin-treated individuals. (LLM, conf=0.84)
Experimental — accuracy not yet measuredSensor‐augmented pump systems (SAP) enable adaptive insulin delivery, including dual‐wave or square‐wave boluses, which distribute insulin over several hours and better match the slow and prolonged glucose absorption typical of DGP, particularly in high‐fat or high‐protein meals.
“Sensor‑augmented pump systems (SAP) enable adaptive insulin delivery, including dual‑wave or square‑wave boluses, which distribute insulin over several hours and better match the slow and prolonged glucose absorption typical of DGP [54, 112, 132, 148, 149], particularly in high‑fat or high‑protein meals [150–152].”
From Diabetic gastroparesis: pathophysiology and impact on insulin timing choices (2026) · cites this paper as [132]
Split into 2 atoms — 0 confirmed, 2 partially supported, 0 disputed, 0 misattributed, 0 unverifiable. Expand the claim to see per-atom verdicts.
Experimental — accuracy not yet measuredDigital innovations in glucose sensing and insulin delivery have improved glycemic management in diabetes and offer particular advantages in patients with DGP, where delayed and variable carbohydrate absorption leads to erratic glycemic excursions.
“Digital innovations in glucose sensing and insulin delivery have improved glycemic management in diabetes and offer particular advantages in patients with DGP, where delayed and variable carbohydrate absorption leads to erratic glycemic excursions [131, 132].”
From Diabetic gastroparesis: pathophysiology and impact on insulin timing choices (2026) · cites this paper as [132]
Split into 2 atoms — 1 confirmed, 1 partially supported, 0 disputed, 0 misattributed, 0 unverifiable. Expand the claim to see per-atom verdicts.
Experimental — accuracy not yet measuredThese data facilitate a dynamic, iterative optimization of insulin dosing, bolus timing, and fractionation, moving away from purely empirical adjustments.
“These data facilitate a dynamic, iterative optimization of insulin dosing, bolus timing, and fractionation, moving away from purely empirical adjustments [132, 143, 145, 146].”
From Diabetic gastroparesis: pathophysiology and impact on insulin timing choices (2026) · cites this paper as [132]
The Data Analysis section (page unavailable) says CGM and automated-insulin-delivery reports reveal glucose patterns and insulin-delivery information that can guide therapy adjustments. The Automated Insulin Delivery Systems section also describes dose modulation based on CGM feedback. These passages support data-guided insulin adjustment, but do not specifically establish optimization of bolus timing or fractionation. (LLM, conf=0.86)
Experimental — accuracy not yet measuredCurrent algorithms are primarily responsive to immediate glycemic changes and may not fully compensate for delayed carbohydrate absorption, especially from meals rich in fat and protein that can induce delayed hyperglycemia.
“However, current algorithms are primarily responsive to immediate glycemic changes and may not fully compensate for delayed carbohydrate absorption, especially from meals rich in fat and protein that can induce delayed hyperglycemia [131, 132, 158].”
From Diabetic gastroparesis: pathophysiology and impact on insulin timing choices (2026) · cites this paper as [132]
The Automated Insulin Delivery Systems section says current algorithms adjust insulin using CGM feedback and predicted glucose levels, commonly 30 minutes or 1 hour ahead, and still require meal announcements to calculate prandial doses. This supports the general description of glucose-responsive algorithms, but the paper does not say they fail to compensate for delayed carbohydrate absorption or link that limitation to high-fat, high-protein meals and delayed hyperglycemia. (LLM, conf=0.83)
Experimental — accuracy not yet measured
With the advent of newer studies of CGM in noninsulin-treated individuals and increasing uptake, the utility of CGM is progressively being endorsed in this population.
“With the advent of newer studies of CGM in noninsulin‐treated individuals and increasing uptake, the utility of CGM is progressively being endorsed in this population.”
The 2025 ADA Standards of Care suggest consideration of both rtCGM and isCGM for adults living with T2DM and using noninsulin therapies who are trying to achieve personalised glycaemic goals (Grade B).
“The 2025 American Diabetes Association (ADA) Standards of Care suggest consideration of both rtCGM and isCGM for adults living with T2DM and using noninsulin therapies who are trying to achieve personalised glycaemic goals (Grade B). 4 , 5”
Periodic CGM use is suggested as an appropriate tool, when continuous CGM is not feasible, especially to support medication or lifestyle adjustments (Grade C).
“Periodic CGM use is also suggested as an appropriate tool, when continuous CGM is not feasible, especially to support medication or lifestyle adjustments (Grade C). 4 , 5”
Periodic CGM use is suggested as an appropriate tool, when continuous CGM is not feasible, especially to support medication or lifestyle adjustments (Grade C).
“Periodic CGM use is also suggested as an appropriate tool, when continuous CGM is not feasible, especially to support medication or lifestyle adjustments (Grade C). 4 , 5”
The 2025 ADA Standards of Care suggest consideration of both rtCGM and isCGM for adults living with T2DM and using noninsulin therapies who are trying to achieve personalised glycaemic goals (Grade B).
“The 2025 American Diabetes Association (ADA) Standards of Care suggest consideration of both rtCGM and isCGM for adults living with T2DM and using noninsulin therapies who are trying to achieve personalised glycaemic goals (Grade B). 4 , 5”
CGM plays a central role by enabling visualization of glycemic trends and revealing patterns that are missed with capillary glucose testing.
“In this context, CGM plays a central role by enabling visualization of glycemic trends and revealing patterns that are missed with capillary glucose testing [132, 133].”
From Diabetic gastroparesis: pathophysiology and impact on insulin timing choices (2026) · cites this paper as [132]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Pump recommendation conflicts with the stated lack of evidence for youth with type 2 diabetes
MajorRecommendation 7.27 says insulin pump therapy should be offered to youth with type 2 diabetes on multiple daily injections. The youth section says there is insufficient evidence to make recommendations for that group.
“7.27 Insulin pump therapy, preferably with CGM, should be offered for diabetes management to youth and adults on MDI with type 2 diabetes who can use the device safely (either by themselves or with a caregiver).”
“Because of a paucity of data in adolescents and youth with type 2 diabetes, there is insufficient evidence to make recommendations.”
Meter-accuracy claim cites a skin-reaction paper
MinorThe text attributes an analysis of glucose-meter accuracy to reference 20, but the listed reference 20 concerns skin issues associated with CGM use.
“In a subsequent analysis with updated glucose meters, 14 of 18 glucose meters met the minimum accuracy requirements (20).”
“20.Pleus S, Ulbrich S, Zschornack E, Kamann S, Haug C, Freckmann G. Documentation of skinrelated issues associated with continuous glucose monitoring use in the scientific literature.Diabetes Technol Ther 2019;21:538-545”
Basal-insulin retrospective study cites a type 1 diabetes trial
MinorThe cited reference 84 is a randomized trial comparing CGM devices in adults with type 1 diabetes, not a retrospective study of adults with type 2 diabetes using basal insulin.
“Similar results were seen in a retrospective study with adults with type 2 diabetes on basal insulin at 3-6 months (84).”
“84.Visser MM, Charleer S, Fieuws S, et al.Comparing real-time and intermittently scanned continuous glucose monitoring in adults with type 1 diabetes (ALERTT1): a 6-month, prospective, multicentre, randomised controlled trial.Lancet 2021;397:2275-2283”
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667 · see citing works
Battelino, T., Danne, T., Bergenstal, R. M., Amiel, S. A., Beck, R., Biester, T., Bosi, E., Buckingham, B. A., Cefalu, W. T., Close, K. L., et al. (2019) · Diabetes Care · doi:10.2337/dci19-0028 · Cited by 4,032 · see citing works
International consensus on use of continuous glucose monitoring
Danne, T., Nimri, R., Battelino, T., Bergenstal, R. M., Close, K. L., DeVries, J. H., Garg, S., Heinemann, L., Hirsch, I., Amiel, S. A., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1600 · Cited by 2,069 · see citing works
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559 · see citing works
Six-Month Randomized, Multicenter Trial of Closed-Loop Control in Type 1 Diabetes
Brown, S. A., Kovatchev, B. P., Raghinaru, D., Lum, J. W., Buckingham, B. A., Kudva, Y. C., Laffel, L. M., Levy, C. J., Pinsker, J. E., Wadwa, R. P., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1907863 · Cited by 1,030 · see citing works
Self-citationBolinder, J., Antuna, R., Geelhoed-Duijvestijn, P., Kröger, J., & Weitgasser, R. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31535-5 · Cited by 893 · see citing works
Feig, D. S., Donovan, L. E., Corcoy, R., Murphy, K. E., Amiel, S. A., Hunt, K. F., Asztalos, E., Barrett, J. F. R., Sanchez, J. J., de Leiva, A., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)32400-5 · Cited by 803 · see citing works
Safety of a hybrid closed-loop insulin delivery system in patients with type 1 diabetes
Bergenstal, R. M., Garg, S., Weinzimer, S. A., Buckingham, B. A., Bode, B. W., Tamborlane, W. V., & Kaufman, F. R. (2016) · JAMA · doi:10.1001/jama.2016.11708 · Cited by 644 · see citing works
Beck, R. W., Riddlesworth, T. D., Ruedy, K., Ahmann, A., Haller, S., Kruger, D., McGill, J. B., Polonsky, W., Price, D., Aronoff, S., et al. (2017) · Annals of Internal Medicine · doi:10.7326/m16-2855 · Cited by 635 · see citing works
Haak, T., Hanaire, H., Ajjan, R., Hermanns, N., Riveline, J.-P., & Rayman, G. (2017) · Diabetes Therapy · doi:10.1007/s13300-016-0223-6 · Cited by 623 · see citing works
Pickup, J. C., & Sutton, A. J. (2008) · Diabetic Medicine · doi:10.1111/j.1464-5491.2008.02486.x · Cited by 618 · see citing works
Garg, S. K., Weinzimer, S. A., Tamborlane, W. V., Buckingham, B. A., Bode, B. W., Bailey, T. S., Brazg, R. L., Ilany, J., Slover, R. H., Anderson, S. M., et al. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0421 · Cited by 585 · see citing works
Martens, T., Beck, R. W., Bailey, R., Ruedy, K. J., Calhoun, P., Peters, A. L., Pop-Busui, R., Philis-Tsimikas, A., Bao, S., Umpierrez, G., et al. (2021) · JAMA · doi:10.1001/jama.2021.7444 · Cited by 543 · see citing works
Self-citationMiller, K. M., Beck, R. W., Bergenstal, R. M., Goland, R. S., Haller, M. J., McGill, J. B., Rodriguez, H., Simmons, J. H., Hirsch, I. B., & for the T1D Exchange Clinic Network (2013) · Diabetes Care · doi:10.2337/dc12-1770 · Cited by 505 · see citing works
Yeh, H.-C., Brown, T. T., Maruthur, N., Ranasinghe, P., Berger, Z., Suh, Y. D., Wilson, L. M., Haberl, E. B., Brick, J., Bass, E. B., et al. (2012) · Annals of Internal Medicine · doi:10.7326/0003-4819-157-5-201209040-00508 · Cited by 493 · see citing works
Karges, B., Schwandt, A., Heidtmann, B., Kordonouri, O., Binder, E., Schierloh, U., Boettcher, C., Kapellen, T., Rosenbauer, J., & Holl, R. W. (2017) · JAMA · doi:10.1001/jama.2017.13994 · Cited by 452 · see citing works
Laffel, L. M., Kanapka, L. G., Beck, R. W., Bergamo, K., Clements, M. A., Criego, A., DeSalvo, D. J., Goland, R., Hood, K., Liljenquist, D., et al. (2020) · JAMA · doi:10.1001/jama.2020.6940 · Cited by 443 · see citing works
Phillip, M., Nimri, R., Bergenstal, R. M., Barnard-Kelly, K., Danne, T., Hovorka, R., Kovatchev, B. P., Messer, L. H., Parkin, C. G., Ambler-Osborn, L., et al. (2023) · Endocrine Reviews · doi:10.1210/endrev/bnac022 · Cited by 443 · see citing works
Self-citationTauschmann, M., Thabit, H., Bally, L., Allen, J. M., Hartnell, S., Wilinska, M. E., Ruan, Y., Sibayan, J., Kollman, C., Cheng, P., et al. (2018) · The Lancet · doi:10.1016/s0140-6736(18)31947-0 · Cited by 440 · see citing works
Polonsky, W. H., Fisher, L., Schikman, C. H., Hinnen, D. A., Parkin, C. G., Jelsovsky, Z., Petersen, B., Schweitzer, M., & Wagner, R. S. (2011) · Diabetes Care · doi:10.2337/dc10-1732 · Cited by 429 · see citing works
Pratley, R. E., Kanapka, L. G., Rickels, M. R., Ahmann, A., Aleppo, G., Beck, R., Bhargava, A., Bode, B. W., Carlson, A., Chaytor, N. S., et al. (2020) · JAMA · doi:10.1001/jama.2020.6928 · Cited by 375 · see citing works
Self-citationDoyle (Boland), E. A., Weinzimer, S. A., Steffen, A. T., Ahern, J. A. H., Vincent, M., & Tamborlane, W. V. (2004) · Diabetes Care · doi:10.2337/diacare.27.7.1554 · Cited by 373 · see citing works
Jeitler, K., Horvath, K., Berghold, A., Gratzer, T. W., Neeser, K., Pieber, T. R., & Siebenhofer, A. (2008) · Diabetologia · doi:10.1007/s00125-008-0974-3 · Cited by 372 · see citing works
Racial-ethnic disparities in management and outcomes among children with type 1 diabetes
Willi, S. M., Miller, K. M., DiMeglio, L. A., Klingensmith, G. J., Simmons, J. H., Tamborlane, W. V., Nadeau, K. J., Kittelsrud, J. M., Huckfeldt, P., Beck, R. W., et al. (2015) · Pediatrics · doi:10.1542/peds.2014-1774 · Cited by 367 · see citing works
Self-monitoring of blood glucose in patients with type 2 diabetes mellitus who are not using insulin
Malanda, U. L., Welschen, L. M., Riphagen, I. I., Dekker, J. M., Nijpels, G., & Bot, S. D. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005060.pub3 · Cited by 358 · see citing works
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023) · Diabetes Care · doi:10.2337/dci23-0036 · Cited by 351 · see citing works
Ziegler, R., Heidtmann, B., Hilgard, D., Hofer, S., Rosenbauer, J., Holl, R., & DPV-Wiss-Initiative, F. T. (2011) · Pediatric Diabetes · doi:10.1111/j.1399-5448.2010.00650.x · Cited by 334 · see citing works
Aleppo, G., Ruedy, K. J., Riddlesworth, T. D., Kruger, D. F., Peters, A. L., Hirsch, I., Bergenstal, R. M., Toschi, E., Ahmann, A. J., Shah, V. N., et al. (2017) · Diabetes Care · doi:10.2337/dc16-2482 · Cited by 329 · see citing works
Self-citationKorytkowski, M. T., Muniyappa, R., Antinori-Lent, K., Donihi, A. C., Drincic, A. T., Hirsch, I. B., Luger, A., McDonnell, M. E., Murad, M. H., Nielsen, C., et al. (2022) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgac278 · Cited by 315 · see citing works
Fleming, G. A., Petrie, J. R., Bergenstal, R. M., Holl, R. W., Peters, A. L., & Heinemann, L. (2020) · Diabetes Care · doi:10.2337/dci19-0062 · Cited by 306 · see citing works
New insulin delivery recommendations
Frid, A. H., Kreugel, G., Grassi, G., Halimi, S., Hicks, D., Hirsch, L. J., Smith, M. J., Wellhoener, R., Bode, B. W., Hirsch, I. B., et al. (2016) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2016.06.010 · Cited by 286 · see citing works
Korytkowski, M., Bell, D., Jacobsen, C., Suwannasari, R., & FlexPen® Study Team (2003) · Clinical Therapeutics · doi:10.1016/s0149-2918(03)80337-5 · Cited by 267 · see citing works
Charleer, S., De Block, C., Van Huffel, L., Broos, B., Fieuws, S., Nobels, F., Mathieu, C., & Gillard, P. (2020) · Diabetes Care · doi:10.2337/dc19-1610 · Cited by 261 · see citing works
Diabetes Technology Update: Use of Insulin Pumps and Continuous Glucose Monitoring in the Hospital
Umpierrez, G. E., & Klonoff, D. C. (2018) · Diabetes Care · doi:10.2337/dci18-0002 · Cited by 255 · see citing works
Peters, A. L., Ahmann, A. J., Battelino, T., Evert, A., Hirsch, I. B., Murad, M. H., Winter, W. E., & Wolpert, H. (2016) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2016-2534 · Cited by 250 · see citing works
Forlenza, G. P., Li, Z., Buckingham, B. A., Pinsker, J. E., Cengiz, E., Wadwa, R. P., Ekhlaspour, L., Church, M. M., Weinzimer, S. A., Jost, E., et al. (2018) · Diabetes Care · doi:10.2337/dc18-0771 · Cited by 246 · see citing works
Self-citationReddy, M., Jugnee, N., El Laboudi, A., Spanudakis, E., Anantharaja, S., & Oliver, N. (2018) · Diabetic Medicine · doi:10.1111/dme.13561 · Cited by 245 · see citing works
Automated insulin delivery in women with pregnancy complicated by type 1 diabetes
Lee, T. T. M., Collett, C., Bergford, S., Hartnell, S., Scott, E. M., Lindsay, R. S., Hunt, K. F., McCance, D. R., Barnard-Kelly, K., Rankin, D., et al. (2023) · New England Journal of Medicine · doi:10.1056/nejmoa2303911 · Cited by 241 · see citing works
Sherr, J. L., Hermann, J. M., Campbell, F., Foster, N. C., Hofer, S. E., Allgrove, J., Maahs, D. M., Kapellen, T. M., Holman, N., Tamborlane, W. V., et al. (2015) · Diabetologia · doi:10.1007/s00125-015-3790-6 · Cited by 236 · see citing works
Reznik, Y., Cohen, O., Aronson, R., Conget, I., Runzis, S., Castaneda, J., & Lee, S. W. (2014) · The Lancet · doi:10.1016/s0140-6736(14)61037-0 · Cited by 233 · see citing works
Carlson, A. L., Sherr, J. L., Shulman, D. I., Garg, S. K., Pop-Busui, R., Bode, B. W., Lilenquist, D. R., Brazg, R. L., Kaiserman, K. B., Kipnes, M. S., et al. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0319 · Cited by 230 · see citing works
Maahs, D. M., Hermann, J. M., Holman, N., Foster, N. C., Kapellen, T. M., Allgrove, J., Schatz, D. A., Hofer, S. E., Campbell, F., Steigleder-Schweiger, C., et al. (2015) · Diabetes Care · doi:10.2337/dc15-0780 · Cited by 224 · see citing works
Safety and effectiveness of insulin pump therapy in children and adolescents with type 1 diabetes
Plotnick, L. P., Clark, L. M., Brancati, F. L., & Erlinger, T. (2003) · Diabetes Care · doi:10.2337/diacare.26.4.1142 · Cited by 216 · see citing works
Multicenter, randomized trial of a bionic pancreas in type 1 diabetes
Bionic Pancreas Research Group (2022) · New England Journal of Medicine · doi:10.1056/nejmoa2205225 · Cited by 216 · see citing works
One year clinical experience of the first commercial hybrid closed-loop system
Lal, R. A., Basina, M., Maahs, D. M., Hood, K., Buckingham, B., & Wilson, D. M. (2019) · Diabetes Care · doi:10.2337/dc19-0855 · Cited by 215 · see citing works
Self-citationThe Effect of Real-Time Continuous Glucose Monitoring in Pregnant Women With Diabetes
Secher, A. L., Ringholm, L., Andersen, H. U., Damm, P., & Mathiesen, E. R. (2013) · Diabetes Care · doi:10.2337/dc12-2360 · Cited by 214 · see citing works
Yaron, M., Roitman, E., Aharon-Hananel, G., Landau, Z., Ganz, T., Yanuv, I., Rozenberg, A., Karp, M., Ish-Shalom, M., Singer, J., et al. (2019) · Diabetes Care · doi:10.2337/dc18-0166 · Cited by 211 · see citing works
Kristensen, K., Ögge, L. E., Sengpiel, V., Kjölhede, K., Dotevall, A., Elfvin, A., Knop, F. K., Wiberg, N., Katsarou, A., Shaat, N., et al. (2019) · Diabetologia · doi:10.1007/s00125-019-4850-0 · Cited by 210 · see citing works
Smartphone apps for calculating insulin dose: a systematic assessment
Huckvale, K., Adomaviciute, S., Prieto, J. T., Leow, M. K., & Car, J. (2015) · BMC Medicine · doi:10.1186/s12916-015-0314-7 · Cited by 200 · see citing works
Ehrhardt, N. M., Chellappa, M., Walker, M. S., Fonda, S. J., & Vigersky, R. A. (2011) · Journal of Diabetes Science and Technology · doi:10.1177/193229681100500320 · Cited by 199 · see citing works
Herman, A., Aerts, O., Baeck, M., Bruze, M., De Block, C., Goossens, A., Hamnerius, N., Huygens, S., Maiter, D., Tennstedt, D., et al. (2017) · Contact Dermatitis · doi:10.1111/cod.12866 · Cited by 192 · see citing works
Karter, A. J., Parker, M. M., Moffet, H. H., Gilliam, L. K., & Dlott, R. (2021) · JAMA · doi:10.1001/jama.2021.6530 · Cited by 191 · see citing works
Trial of Hybrid Closed-Loop Control in Young Children with Type 1 Diabetes
Wadwa, R. P., Reed, Z. W., Buckingham, B. A., DeBoer, M. D., Ekhlaspour, L., Forlenza, G. P., Schoelwer, M., Lum, J., Kollman, C., Beck, R. W., et al. (2023) · New England Journal of Medicine · doi:10.1056/nejmoa2210834 · Cited by 191 · see citing works
Self-citationContinuous glucose monitoring in adults with type 2 diabetes: a systematic review and meta-analysis
Jancev, M., Vissers, T. A. C. M., Visseren, F. L. J., van Bon, A. C., Serné, E. H., DeVries, J. H., de Valk, H. W., & van Sloten, T. T. (2024) · Diabetologia · doi:10.1007/s00125-024-06107-6 · Cited by 191 · see citing works
Teo, E., Hassan, N., Tam, W., & Koh, S. (2022) · Diabetologia · doi:10.1007/s00125-021-05648-4 · Cited by 186 · see citing works
Open-source automated insulin delivery in type 1 diabetes
Burnside, M. J., Lewis, D. M., Crocket, H. R., Meier, R. A., Williman, J. A., Sanders, O. J., Jefferies, C. A., Faherty, A. M., Paul, R. G., Lever, C. S., et al. (2022) · New England Journal of Medicine · doi:10.1056/nejmoa2203913 · Cited by 183 · see citing works
Safety Evaluation of the MiniMed 670G System in Children 7–13 Years of Age with Type 1 Diabetes
Forlenza, G. P., Pinhas‐Hamiel, O., Liljenquist, D. R., Shulman, D. I., Bailey, T. S., Bode, B. W., Wood, M. A., Buckingham, B. A., Kaiserman, K. B., Shin, J., et al. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0264 · Cited by 182 · see citing works
Deshmukh, H., Wilmot, E. G., Gregory, R., Barnes, D., Narendran, P., Saunders, S., Furlong, N., Kamaruddin, S., Banatwalla, R., Herring, R., et al. (2020) · Diabetes Care · doi:10.2337/dc20-0738 · Cited by 175 · see citing works
Intermittently scanned continuous glucose monitoring for type 1 diabetes
Leelarathna, L., Evans, M. L., Neupane, S., Rayman, G., Lumley, S., Cranston, I., Narendran, P., Barnard-Kelly, K., Sutton, C. J., Elliott, R. A., et al. (2022) · New England Journal of Medicine · doi:10.1056/nejmoa2205650 · Cited by 174 · see citing works
Roussel, R., Riveline, J.-P., Vicaut, E., de Pouvourville, G., Detournay, B., Emery, C., Levrat-Guillen, F., & Guerci, B. (2021) · Diabetes Care · doi:10.2337/dc20-1690 · Cited by 173 · see citing works
Continuous glucose monitors and automated insulin dosing systems in the hospital consensus guideline
Galindo, R. J., Umpierrez, G. E., Rushakoff, R. J., Basu, A., Lohnes, S., Nichols, J. H., Spanakis, E. K., Espinoza, J., Palermo, N. E., Awadjie, D. G., et al. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820954163 · Cited by 170 · see citing works
Self-citationTyndall, V., Stimson, R. H., Zammitt, N. N., Ritchie, S. A., McKnight, J. A., Dover, A. R., & Gibb, F. W. (2019) · Diabetologia · doi:10.1007/s00125-019-4894-1 · Cited by 165 · see citing works
Visser, M. M., Charleer, S., Fieuws, S., De Block, C., Hilbrands, R., Van Huffel, L., Maes, T., Vanhaverbeke, G., Dirinck, E., Myngheer, N., et al. (2021) · The Lancet · doi:10.1016/s0140-6736(21)00789-3 · Cited by 165 · see citing works
Davis, G. M., Spanakis, E. K., Migdal, A. L., Singh, L. G., Albury, B., Urrutia, M. A., Zamudio-Coronado, K. W., Scott, W. H., Doerfler, R., Lizama, S., et al. (2021) · Diabetes Care · doi:10.2337/dc20-2856 · Cited by 160 · see citing works
Barnard, K. D., Wysocki, T., Allen, J. M., Elleri, D., Thabit, H., Leelarathna, L., Gulati, A., Nodale, M., Dunger, D. B., Tinati, T., et al. (2014) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2014-000025 · Cited by 159 · see citing works
Wada, E., Onoue, T., Kobayashi, T., Handa, T., Hayase, A., Ito, M., Furukawa, M., Okuji, T., Okada, N., Iwama, S., et al. (2020) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2019-001115 · Cited by 157 · see citing works
Galindo, R. J., Aleppo, G., Klonoff, D. C., Spanakis, E. K., Agarwal, S., Vellanki, P., Olson, D. E., Umpierrez, G. E., Davis, G. M., & Pasquel, F. J. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820932903 · Cited by 155 · see citing works
Self-citationSingh, L. G., Satyarengga, M., Marcano, I., Scott, W. H., Pinault, L. F., Feng, Z., Sorkin, J. D., Umpierrez, G. E., & Spanakis, E. K. (2020) · Diabetes Care · doi:10.2337/dc20-0840 · Cited by 154 · see citing works
Spanakis, E. K., Urrutia, A., Galindo, R. J., Vellanki, P., Migdal, A. L., Davis, G., Fayfman, M., Idrees, T., Pasquel, F. J., Coronado, W. Z., et al. (2022) · Diabetes Care · doi:10.2337/dc22-0716 · Cited by 153 · see citing works
Lum, J. W., Bailey, R. J., Barnes-Lomen, V., Naranjo, D., Hood, K. K., Lal, R. A., Arbiter, B., Brown, A. S., DeSalvo, D. J., Pettus, J., et al. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0535 · Cited by 150 · see citing works
Self-citationYoung, L. A., Buse, J. B., Weaver, M. A., Vu, M. B., Mitchell, C. M., Blakeney, T., Grimm, K., Rees, J., Niblock, F., Donahue, K. E., et al. (2017) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2017.1233 · Cited by 148 · see citing works
Yang, Y., Lee, E. Y., Kim, H.-S., Lee, S.-H., Yoon, K.-H., & Cho, J.-H. (2020) · JMIR mHealth and uHealth · doi:10.2196/16266 · Cited by 148 · see citing works
Hásková, A., Radovnická, L., Petruželková, L., Parkin, C. G., Grunberger, G., Horová, E., Navrátilová, V., Kádě, O., Matoulek, M., Prázný, M., et al. (2020) · Diabetes Care · doi:10.2337/dc20-0112 · Cited by 146 · see citing works
Investigation of the Accuracy of 18 Marketed Blood Glucose Monitors
Klonoff, D. C., Parkes, J. L., Kovatchev, B. P., Kerr, D., Bevier, W. C., Brazg, R. L., Christiansen, M., Bailey, T. S., Nichols, J. H., & Kohn, M. A. (2018) · Diabetes Care · doi:10.2337/dc17-1960 · Cited by 144 · see citing works
Sepah, S. C., Jiang, L., & Peters, A. L. (2014) · The Diabetes Educator · doi:10.1177/0145721714531339 · Cited by 139 · see citing works
Continuous glucose monitoring in the intensive care unit during the COVID-19 pandemic
Agarwal, S., Mathew, J., Davis, G. M., Shephardson, A., Levine, A., Louard, R., Urrutia, A., Perez-Guzman, C., Umpierrez, G. E., Peng, L., et al. (2021) · Diabetes Care · doi:10.2337/dc20-2219 · Cited by 138 · see citing works
Phillip, M., Bergenstal, R. M., Close, K. L., Danne, T., Garg, S. K., Heinemann, L., Hirsch, I. B., Kovatchev, B. P., Laffel, L. M., Mohan, V., et al. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0375 · Cited by 135 · see citing works
McCall, A. L., Lieb, D. C., Gianchandani, R. Y., MacMaster, H. W., Maynard, G. A., Murad, M. H., Seaquist, E. R., Wolfsdorf, J. I., Wright, R. F., & Wiercioch, W. (2022) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgac596 · Cited by 134 · see citing works
Benhalima, K., Beunen, K., Van Wilder, N., Ballaux, D., Vanhaverbeke, G., Taes, Y., Aers, X.-P., Nobels, F., Marlier, J., Lee, D., et al. (2024) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(24)00089-5 · Cited by 131 · see citing works
Braune, K., Lal, R. A., Petruželková, L., Scheiner, G., Winterdijk, P., Schmidt, S., Raimond, L., Hood, K. K., Riddell, M. C., Skinner, T. C., et al. (2022) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(21)00267-9 · Cited by 130 · see citing works
Self-citationSherr, J. L., Cengiz, E., Palerm, C. C., Clark, B., Kurtz, N., Roy, A., Carria, L., Cantwell, M., Tamborlane, W. V., & Weinzimer, S. A. (2013) · Diabetes Care · doi:10.2337/dc13-0010 · Cited by 125 · see citing works
Aronson, R., Brown, R. E., Chu, L., Bajaj, H. S., Khandwala, H., Abitbol, A., Malakieh, N., & Goldenberg, R. (2023) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.14949 · Cited by 118 · see citing works
Wright, E. E., Kerr, M. S. D., Reyes, I. J., Nabutovsky, Y., & Miller, E. (2021) · Diabetes Spectrum · doi:10.2337/ds20-0069 · Cited by 115 · see citing works
Forlenza, G. P., Ekhlaspour, L., Breton, M. D., Maahs, D. M., Wadwa, R. P., DeBoer, M. D., Messer, L. H., Town, M., Pinnata, J., Kruse, G., et al. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0011 · Cited by 108 · see citing works
Self-citationFortmann, A., Bagsic, S. R. S., Talavera, L., Garcia, I. M., Sandoval, H., Hottinger, A., & Philis-Tsimikas, A. (2020) · Diabetes Care · doi:10.2337/dc20-1016 · Cited by 107 · see citing works
Racial/Ethnic Minority Youth With Recent-Onset Type 1 Diabetes Have Poor Prognostic Factors
REDONDO, M. J., Libman, I. M., Cheng, P., Kollman, C., Tosur, M., Gal, R. L., Bacha, F. F., KLINGENSMITH, G. J., Clements, M. A., REDONDO, M. J., et al. (2018) · Diabetes Care · doi:10.2337/dc17-2335 · Cited by 104 · see citing works
Johnson, M. L., Martens, T. W., Criego, A. B., Carlson, A. L., Simonson, G. D., & Bergenstal, R. M. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0034 · Cited by 104 · see citing works
Beck, R. W., Kanapka, L., Breton, M. D., Brown, S. A., Wadwa, R., Buckingham, B. A., Kollman, C., & Kovatchev, B. P. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0558 · Cited by 102 · see citing works
Tumminia, A., Crimi, S., Sciacca, L., Buscema, M., Frittitta, L., Squatrito, S., Vigneri, R., & Tomaselli, L. (2015) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.2557 · Cited by 100 · see citing works
García‐Moreno, R. M., Benítez‐Valderrama, P., Barquiel, B., González Pérez‐de‐Villar, N., Hillman, N., Lora Pablos, D., & Herranz, L. (2022) · Diabetic Medicine · doi:10.1111/dme.14703 · Cited by 100 · see citing works
WEI, Q., SUN, Z., YANG, Y., YU, H., DING, H., & WANG, S. (2016) · Scientific Reports · doi:10.1038/srep19920 · Cited by 99 · see citing works
Forlenza, G. P., DeSalvo, D. J., Aleppo, G., Wilmot, E. G., Berget, C., Huyett, L. M., Hadjiyianni, I., Méndez, J. J., Conroy, L. R., Ly, T. T., et al. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0578 · Cited by 99 · see citing works
Self-citationBreton, M. D., Patek, S. D., Lv, D., Schertz, E. M., Robic, J., Pinnata, J., Kollar, L. L., Barnett, C. L., WAKEMAN, C. A., Oliveri, M. C., et al. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0079 · Cited by 98 · see citing works
Strategies to Enhance New CGM Use in Early Childhood (SENCE) Study Group, Laffel, L., Harrington, K., Hanono, A., Naik, N., Ambler-Osborn, L., Schultz, A., DiMeglio, L., Woerne, S., Jolivette, H., et al. (2021) · Diabetes Care · doi:10.2337/dc20-1060 · Cited by 95 · see citing works
Treat-to-target trials: uses, interpretation and review of concepts
Garber, A. J. (2014) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.12129 · Cited by 94 · see citing works
Davis, G. M., Faulds, E., Walker, T., Vigliotti, D., Rabinovich, M., Hester, J., Peng, L., McLean, B., Hannon, P., Poindexter, N., et al. (2021) · Diabetes Care · doi:10.2337/dc20-2085 · Cited by 94 · see citing works
Sherr, J. L., Buckingham, B. A., Forlenza, G. P., Galderisi, A., Ekhlaspour, L., Wadwa, R. P., Carria, L., Hsu, L., Berget, C., Peyser, T. A., et al. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0286 · Cited by 92 · see citing works
Self-citationFerreira, R. O. M., Trevisan, T., Pasqualotto, E., Chavez, M. P., Marques, B. F., Lamounier, R. N., & van de Sande-Lee, S. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0390 · Cited by 92 · see citing works
Managing diabetes in preschool children
Sundberg, F., Barnard, K., Cato, A., de Beaufort, C., DiMeglio, L. A., Dooley, G., Hershey, T., Hitchcock, J., Jain, V., Weissberg-Benchell, J., et al. (2017) · Pediatric Diabetes · doi:10.1111/pedi.12554 · Cited by 91 · see citing works
Mannucci, E., Antenore, A., Giorgino, F., & Scavini, M. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817719290 · Cited by 90 · see citing works
Karageorgiou, V., Papaioannou, T., Bellos, I., Alexandraki, K., Tentolouris, N., Stefanadis, C., Chrousos, G. P., & Tousoulis, D. (2018) · Metabolism · doi:10.1016/j.metabol.2018.10.002 · Cited by 89 · see citing works
Longo, R. R., Elias, H., Khan, M., & Seley, J. J. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968211008446 · Cited by 89 · see citing works
Self-citationHaynes, A., Hermann, J. M., Miller, K. M., Hofer, S. E., Jones, T. W., Beck, R. W., Maahs, D. M., Davis, E. A., Holl, R. W., & for the T1D Exchange, W. A. D. R. (2017) · Pediatric Diabetes · doi:10.1111/pedi.12477 · Cited by 88 · see citing works
Bergenstal, R. M., Johnson, M., Passi, R., Bhargava, A., Young, N., Kruger, D. F., Bashan, E., Bisgaier, S. G., Isaman, D. J. M., & Hodish, I. (2019) · The Lancet · doi:10.1016/s0140-6736(19)30368-x · Cited by 88 · see citing works
Allergic contact dermatitis caused by glucose sensors in type 1 diabetes patients
Hyry, H., Liippo, J., & Virtanen, H. M. (2019) · Contact Dermatitis · doi:10.1111/cod.13337 · Cited by 87 · see citing works
MCVEAN, J. J. F., Forlenza, G. P., Beck, R. W., Bauza, C., Bailey, R. J., Buckingham, B. A., DiMeglio, L. A., Sherr, J. L., Clements, M., Neyman, A., et al. (2023) · JAMA · doi:10.1001/jama.2023.2063 · Cited by 87 · see citing works
Self-citationKamann, S., Aerts, O., & Heinemann, L. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818762946 · Cited by 85 · see citing works
Bollyky, J. B., Bravata, D., Yang, J., Williamson, M., & Schneider, J. (2018) · Journal of Diabetes Research · doi:10.1155/2018/3961730 · Cited by 85 · see citing works
Sadhu, A. R., Serrano, I. A., Xu, J., Nisar, T., Lucier, J., Pandya, A. R., & Patham, B. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820964264 · Cited by 84 · see citing works
Health economics and compliance of vials/syringes versus pen devices: a review of the evidence
Asche, C. V., Shane-McWhorter, L., & Raparla, S. (2010) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0180 · Cited by 83 · see citing works
Addala, A., Maahs, D. M., Scheinker, D., Chertow, S., Leverenz, B., & Prahalad, P. (2020) · Pediatric Diabetes · doi:10.1111/pedi.13082 · Cited by 83 · see citing works
Chao, D. Y., Lin, T. M., & Ma, W.-Y. (2019) · JMIR Diabetes · doi:10.2196/11017 · Cited by 82 · see citing works
Aleppo, G., Beck, R. W., Bailey, R., Ruedy, K. J., Calhoun, P., Peters, A. L., Pop-Busui, R., Philis-Tsimikas, A., Bao, S., Umpierrez, G., et al. (2021) · Diabetes Care · doi:10.2337/dc21-1304 · Cited by 82 · see citing works
Self-citationPrahalad, P., Ding, V. Y., Zaharieva, D. P., Addala, A., Johari, R., Scheinker, D., Desai, M., Hood, K., & Maahs, D. M. (2022) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgab859 · Cited by 82 · see citing works
Lin, M. H., Connor, C. G., Ruedy, K. J., Beck, R. W., Kollman, C., Buckingham, B., Redondo, M. J., Schatz, D., Haro, H., Lee, J. M., et al. (2013) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0132 · Cited by 81 · see citing works
New, J. P., Ajjan, R., Pfeiffer, A. F. H., & Freckmann, G. (2015) · Diabetic Medicine · doi:10.1111/dme.12713 · Cited by 81 · see citing works
Evidence-based mHealth chronic disease mobile app intervention design: Development of a framework
Wilhide III, C. C., Peeples, M. M., & Anthony Kouyaté, R. C. (2016) · JMIR Research Protocols · doi:10.2196/resprot.4838 · Cited by 81 · see citing works
Asarani, N. A. M., Reynolds, A. N., Styles, S. E., de Bock, M. I., & Wheeler, B. J. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819870849 · Cited by 81 · see citing works
Bao, S., Bailey, R., Calhoun, P., & Beck, R. W. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0494 · Cited by 81 · see citing works
Lorenz, C., Sandoval, W., & Mortellaro, M. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0028 · Cited by 80 · see citing works
A virtual type 2 diabetes clinic using continuous glucose monitoring and endocrinology visits
Dixon, R. F., Zisser, H., Layne, J. E., Barleen, N. A., Miller, D. P., Moloney, D. P., Majithia, A. R., Gabbay, R. A., & Riff, J. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819888662 · Cited by 80 · see citing works
Ajjan, R. A., Jackson, N., & Thomson, S. A. (2019) · Diabetes and Vascular Disease Research · doi:10.1177/1479164119827456 · Cited by 79 · see citing works
Translating HbA1c measurements into estimated average glucose values in pregnant women with diabetes
Law, G. R., Gilthorpe, M. S., Secher, A. L., Temple, R., Bilous, R., Mathiesen, E. R., Murphy, H. R., & Scott, E. M. (2017) · Diabetologia · doi:10.1007/s00125-017-4205-7 · Cited by 77 · see citing works
COMMISSARIAT, P. V., Boyle, C. T., Miller, K. M., Mantravadi, M., DeSalvo, D. J., Tamborlane, W. V., Name, M. A. V., Anderson, B. J., DiMeglio, L. A., & Laffel, L. M. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0375 · Cited by 77 · see citing works
Ekhlaspour, L., Forlenza, G. P., Cherñavvsky, D. R., Maahs, D. M., Wadwa, R. P., DeBoer, M. D., Messer, L. H., Town, M., Pinnata, J., Kruse, G., et al. (2019) · Pediatric Diabetes · doi:10.1111/pedi.12867 · Cited by 77 · see citing works
Self-citationPrice, D. A., Deng, Q., Kipnes, M., & Beck, S. E. (2021) · Diabetes Therapy · doi:10.1007/s13300-021-01086-y · Cited by 77 · see citing works
Champakanath, A., Akturk, H. K., Alonso, G. T., Snell-Bergeon, J. K., & Shah, V. N. (2022) · Diabetes Care · doi:10.2337/dc21-2004 · Cited by 76 · see citing works
Miller, K. M., Kanapka, L. G., Rickels, M. R., Ahmann, A. J., Aleppo, G., Ang, L., Bhargava, A., Bode, B. W., Carlson, A., Chaytor, N. S., et al. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0503 · Cited by 73 · see citing works
Self-citationForlenza, G. P., Carlson, A. L., Galindo, R. J., Kruger, D. F., Levy, C. J., McGill, J. B., Umpierrez, G., & Aleppo, G. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0206 · Cited by 70 · see citing works
Self-citationMoon, S. J., Kim, K., Lee, W. J., Lee, M. Y., Vigersky, R., & Park, C. (2023) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.14852 · Cited by 69 · see citing works
Davis, G. M., Peters, A. L., Bode, B. W., Carlson, A. L., Dumais, B., Vienneau, T. E., Huyett, L. M., & Ly, T. T. (2023) · Diabetes Care · doi:10.2337/dc22-1915 · Cited by 69 · see citing works
Brazg, R. L., Klaff, L. J., & Parkin, C. G. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700117 · Cited by 68 · see citing works
Anderson, S. M., Buckingham, B. A., Breton, M. D., Robic, J. L., Barnett, C. L., Wakeman, C. A., Oliveri, M. C., Brown, S. A., Ly, T. T., Clinton, P. K., et al. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0018 · Cited by 68 · see citing works
Braune, K., Gajewska, K. A., Thieffry, A., Lewis, D. M., Froment, T., O'Donnell, S., Speight, J., Hendrieckx, C., Schipp, J., Skinner, T., et al. (2021) · Journal of Medical Internet Research · doi:10.2196/25409 · Cited by 67 · see citing works
Reviewing U.S. connected diabetes care: the newest member of the team
Levine, B. J., Close, K. L., & Gabbay, R. A. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0273 · Cited by 66 · see citing works
Interferences with CGM systems: practical relevance?
Heinemann, L. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/19322968211065065 · Cited by 65 · see citing works
Insulin pump-associated adverse events in children and adolescents–a prospective study
Wheeler, B. J., Heels, K., Donaghue, K. C., Reith, D. M., & Ambler, G. R. (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0388 · Cited by 64 · see citing works
Opipari-Arrigan, L., Fredericks, E. M., Burkhart, N., Dale, L., Hodge, M., & Foster, C. (2007) · Pediatric Diabetes · doi:10.1111/j.1399-5448.2007.00283.x · Cited by 64 · see citing works
Grace, T., & Salyer, J. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0212 · Cited by 64 · see citing works
Riveline, J.-P., Roussel, R., Vicaut, E., de Pouvourville, G., Detournay, B., Emery, C., Levrat-Guillen, F., & Guerci, B. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0085 · Cited by 64 · see citing works
Alemzadeh, R., Ellis, J. N., Holzum, M. K., Parton, E. A., & Wyatt, D. T. (2004) · Pediatrics · doi:10.1542/peds.114.1.e91 · Cited by 63 · see citing works
Lasalvia, P., Barahona-Correa, J. E., Romero-Alvernia, D. M., Gil-Tamayo, S., Castañeda-Cardona, C., Bayona, J. G., Triana, J. J., Laserna, A. F., Mejía-Torres, M., Restrepo-Jimenez, P., et al. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816633721 · Cited by 63 · see citing works
Evaluation of Pump Discontinuation and Associated Factors in the T1D Exchange Clinic Registry
Wong, J. C., Boyle, C., DiMeglio, L. A., Mastrandrea, L. D., Abel, K.-L., Cengiz, E., Cemeroglu, P. A., Aleppo, G., Largay, J. F., Foster, N. C., et al. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816663963 · Cited by 63 · see citing works
Self-citationNathanson, D., Svensson, A.-M., Miftaraj, M., Franzén, S., Bolinder, J., & Eeg-Olofsson, K. (2021) · Diabetologia · doi:10.1007/s00125-021-05437-z · Cited by 61 · see citing works
REDONDO, M. J., Connor, C. G., Ruedy, K. J., Beck, R. W., Kollman, C., Wood, J., Buckingham, B. A., KLINGENSMITH, G. J., Silverstein, J. H., & Tamborlane, W. V. (2013) · Pediatric Diabetes · doi:10.1111/pedi.12061 · Cited by 60 · see citing works
A novel pen-based Bluetooth-enabled insulin delivery system with insulin dose tracking and advice
Bailey, T. S., & Stone, J. Y. (2017) · Expert Opinion on Drug Delivery · doi:10.1080/17425247.2017.1313831 · Cited by 60 · see citing works
Beato-Víbora, P. I., Quirós-López, C., Lázaro-Martín, L., Martín-Frías, M., Barrio-Castellanos, R., Gil-Poch, E., Arroyo-Díez, F. J., & Giménez-Álvarez, M. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0199 · Cited by 60 · see citing works
Randomized Controlled Trial of Mobile Closed-Loop Control
Kovatchev, B., Anderson, S. M., Raghinaru, D., Kudva, Y. C., Laffel, L. M., Levy, C., Pinsker, J. E., Wadwa, R. P., Buckingham, B., Doyle, F. J., et al. (2020) · Diabetes Care · doi:10.2337/dc19-1310 · Cited by 60 · see citing works
Self-citationContinuous glucose monitoring pilot in low-income type 1 diabetes patients
Sequeira, P. A., Montoya, L., Ruelas, V., Xing, D., Chen, V., Beck, R., & Peters, A. L. (2013) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0072 · Cited by 59 · see citing works
Bionic Pancreas Research Group, Messer, L. H., Buckingham, B. A., Cogen, F., Daniels, M., Forlenza, G., Jafri, R. Z., Mauras, N., Muir, A., Wadwa, R. P., et al. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0201.pub · Cited by 59 · see citing works
Real-world evidence of automated insulin delivery system use
Considine, E. G., & Sherr, J. L. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0442 · Cited by 59 · see citing works
Berghaeuser, M., Kapellen, T., Heidtmann, B., Haberland, H., Klinkert, C., Holl, R., & for the DPV-Science-Initiative and the German working group for insulin pump treatment in paediatric patients (2008) · Pediatric Diabetes · doi:10.1111/j.1399-5448.2008.00416.x · Cited by 58 · see citing works
Rigo, R. S., Levin, L. E., Belsito, D. V., Garzon, M. C., Gandica, R., & Williams, K. M. (2021) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820918894 · Cited by 58 · see citing works
Yoo, J. H., Kim, G., Lee, H. J., Sim, K. H., Jin, S.-M., & Kim, J. H. (2022) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2022.109209 · Cited by 58 · see citing works
Szmuilowicz, E. D., Levy, C. J., Buschur, E., & Polsky, S. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0540 · Cited by 58 · see citing works
Self-citationGrassi, B. A., Gómez, A. M., Calliari, L. E., Franco, D. R., Raggio, M., Riera, F., Castro, M., MCVEAN, J. J. F., van den Heuvel, T. R. A., Arrieta, A., et al. (2023) · Diabetes Obesity and Metabolism · doi:10.1111/dom.15023 · Cited by 57 · see citing works
The role of automated insulin delivery technology in diabetes
Boughton, C. K., & Hovorka, R. (2024) · Diabetologia · doi:10.1007/s00125-024-06165-w · Cited by 57 · see citing works
Glycemic Outcomes of Use of CLC Versus PLGS in Type 1 Diabetes: A Randomized Controlled Trial
Brown, S. A., Beck, R. W., Raghinaru, D., Buckingham, B. A., Laffel, L. M., Wadwa, R. P., Kudva, Y. C., Levy, C. J., Pinsker, J. E., Dassau, E., et al. (2020) · Diabetes Care · doi:10.2337/dc20-0124 · Cited by 55 · see citing works
Self-citationShen, Y., Wang, F., Zhang, X., Zhu, X., Sun, Q., Fisher, E., & Sun, X. (2018) · Journal of Medical Internet Research · doi:10.2196/jmir.9133 · Cited by 54 · see citing works
Technology Integration: The Role of the Diabetes Care and Education Specialist in Practice
Isaacs, D. M., Cox, C. E., Schwab, K., Oser, T. K., RINKER, J. K., Mason, M. J., Greenwood, D. A., & Albanese-O’Neill, A. (2020) · The Science of Diabetes Self-Management and Care · doi:10.1177/0145721720935123 · Cited by 54 · see citing works
Wong, J. C., Dolan, L. M., Yang, T. T., & Hood, K. K. (2015) · Pediatric Diabetes · doi:10.1111/pedi.12221 · Cited by 53 · see citing works
Karakus, K. E., Akturk, H. K., Alonso, G. T., Snell-Bergeon, J. K., & Shah, V. N. (2023) · Diabetes Care · doi:10.2337/dc23-0495 · Cited by 52 · see citing works
Birkebæk, N., Drivvoll, A., Aakesson, K., Bjarnason, R. G., Johansen, A., Samuelsson, U., Skrivarhaug, T., Þórsson, Á. V., & Svensson, J. (2017) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2016-000377 · Cited by 51 · see citing works
Patton, S. R., Noser, A. E., Youngkin, E. M., Majidi, S., & Clements, M. A. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0026 · Cited by 51 · see citing works
Boucher, S. E., Gray, A. R., Wiltshire, E. J., de Bock, M. I., Galland, B. C., Tomlinson, P. A., Rayns, J. A., MacKenzie, K. E., Chan, H., Rose, S., et al. (2020) · Diabetes Care · doi:10.2337/dc20-0613 · Cited by 51 · see citing works
Gellad, W. F., Zhao, X., Thorpe, C. T., Mor, M. K., Good, C. B., & Fine, M. J. (2014) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2014.5405 · Cited by 50 · see citing works
Flash CGM associated with event reduction in nonintensive diabetes therapy
(2021) · The American Journal of Managed Care · doi:10.37765/ajmc.2021.88780 · Cited by 49 · see citing works
Accuracy of continuous glucose monitors for inpatient diabetes management
Wright, J. J., Williams, A. J., Friedman, S. B., Weaver, R. G., Williams, J. M., Hodge, E., Fowler, M., & Bao, S. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221076562 · Cited by 49 · see citing works
Psychosocial impact of the bionic pancreas during summer camp
Weissberg-Benchell, J., Hessler, D., Polonsky, W. H., & Fisher, L. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816640289 · Cited by 47 · see citing works
Buckingham, B. A., Christiansen, M. P., Forlenza, G. P., Wadwa, R. P., Peyser, T. A., Lee, J. B., OCONNOR, J. B., Dassau, E., Huyett, L. M., Layne, J. E., et al. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0138 · Cited by 47 · see citing works
Pleus, S., Ulbrich, S., Zschornack, E., Kamann, S., Haug, C., & Freckmann, G. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0171 · Cited by 47 · see citing works
Self-monitoring diabetes with multiple mobile health devices
Shaw, R. J., Yang, Q., Barnes, A. H., Hatch, D., Crowley, M. J. P., Vorderstrasse, A. A., Vaughn, J., Diane, A., Lewinski, A. A., Jiang, M., et al. (2020) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocaa007 · Cited by 46 · see citing works
Yeh, T., Yeung, M., & Curanaj, F. A. M. (2021) · Current Diabetes Reports · doi:10.1007/s11892-021-01375-7 · Cited by 46 · see citing works
Deiss, D., Irace, C., Carlson, G., Tweden, K. S., & Kaufman, F. R. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0159 · Cited by 44 · see citing works
Dosing Accuracy of Insulin Pens Versus Conventional Syringes and Vials
Luijf, Y. M., & DeVries, J. H. (2010) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0178 · Cited by 43 · see citing works
Vigersky, R. A., Huang, S., Cordero, T. L., Shin, J., Lee, S. W., Chhabra, H., Kaufman, F. R., & Cohen, O. (2018) · Endocrine Practice · doi:10.4158/ep-2017-0234 · Cited by 43 · see citing works
Sandig, D., Grimsmann, J. M., Reinauer, C., Melmer, A., Zimny, S., Müller-Korbsch, M., Forestier, N., Zeyfang, A., Bramlage, P., Danne, T., et al. (2020) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0019 · Cited by 43 · see citing works
Hohendorff, J., Gumprecht, J., Mysliwiec, M., Zozulinska-Ziolkiewicz, D., & Malecki, M. T. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0034 · Cited by 43 · see citing works
Borel, A.-L., Lablanche, S., Waterlot, C., Joffray, E., Barra, C., Arnol, N., Amougay, H., & Benhamou, P.-Y. (2024) · Diabetes Care · doi:10.2337/dc24-0623 · Cited by 43 · see citing works
Tanenbaum, M. L., Zaharieva, D. P., Addala, A., Ngo, J., Prahalad, P., Leverenz, B., New, C., Maahs, D. M., & Hood, K. K. (2021) · Diabetic Medicine · doi:10.1111/dme.14567 · Cited by 42 · see citing works
Friedman, J. G., Cardona, Z., Szmuilowicz, E. D., & Aleppo, G. (2023) · Pharmacogenomics and Personalized Medicine · doi:10.2147/pgpm.s374663 · Cited by 42 · see citing works
Self-citationDanne, T. P. A., Joubert, M., Hartvig, N. V., Kaas, A., Knudsen, N. N., & Mader, J. K. (2024) · Diabetes Care · doi:10.2337/dc23-2176 · Cited by 42 · see citing works
Slabaugh, S. L., Bouchard, J. R., Li, Y., Baltz, J. C., Meah, Y. A., & Moretz, D. C. (2015) · Advances in Therapy · doi:10.1007/s12325-015-0266-5 · Cited by 41 · see citing works
Öberg, U., Isaksson, U., Jutterström, L., Orre, C. J., & Hörnsten, Å. (2018) · JMIR Diabetes · doi:10.2196/diabetes.9059 · Cited by 41 · see citing works
In-Hospital Management of Adults Using Insulin Pump Therapy
Houlden, R. L., & Moore, S. (2014) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2014.01.011 · Cited by 40 · see citing works
Real-World Data from the First U.S. Commercial Users of an Implantable Continuous Glucose Sensor
Sanchez, P., Ghosh-Dastidar, S., Tweden, K. S., & Kaufman, F. R. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0234 · Cited by 40 · see citing works
Ushigome, E., Yamazaki, M., Hamaguchi, M., Ito, T., Matsubara, S., Tsuchido, Y., Kasamatsu, Y., Nakanishi, M., Fujita, N., & Fukui, M. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0237 · Cited by 40 · see citing works
Bionic Pancreas Research Group, Beck, R. W., Russell, S. J., Damiano, E. R., El-Khatib, F. H., Ruedy, K. J., Balliro, C., Li, Z., & Calhoun, P. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0167 · Cited by 40 · see citing works
Chesser, H., Srinivasan, S., Puckett, C., Gitelman, S. E., & Wong, J. C. (2024) · Journal of Diabetes Science and Technology · doi:10.1177/19322968221139873 · Cited by 40 · see citing works
Petruzelkova, L., Neuman, V., Plachy, L., Kozak, M., Obermannova, B., Kolouskova, S., Pruhova, S., & Sumnik, Z. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0562 · Cited by 40 · see citing works
Ahmann, A., Szeinbach, S. L., Gill, J., Traylor, L., & Garg, S. K. (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0172 · Cited by 39 · see citing works
Bergenstal, R. M., Peyrot, M. F., Dreon, D. M., Aroda, V. R., Bailey, T. S., Brazg, R., Frías, J. P., Johnson, M. L., Klonoff, D. C., Kruger, D. F., et al. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0298 · Cited by 39 · see citing works
Allergic contact dermatitis in pediatric patients with type 1 diabetes: An emerging issue
Lombardo, F., Salzano, G., Crisafulli, G., Panasiti, I., Alibrandi, A., Messina, M. F., Pajno, G. B., Caminiti, L., & Passanisi, S. (2020) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2020.108089 · Cited by 39 · see citing works
Time in range in pregnancy: is there a role?
Wyckoff, J. A., & Brown, F. M. (2021) · Diabetes Spectrum · doi:10.2337/ds20-0103 · Cited by 39 · see citing works
Polsky, S., Buschur, E., Dungan, K., Garcetti, R., Nease, E., Malecha, E., Bartholomew, A., Johnson, C., Pyle, L., & Snell-Bergeon, J. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2024.0012 · Cited by 39 · see citing works
Self-citationLeahy, J. L., Aleppo, G., Fonseca, V. A., Garg, S. K., Hirsch, I. B., McCall, A. L., McGill, J. B., & Polonsky, W. H. (2019) · Journal of the Endocrine Society · doi:10.1210/js.2019-00222 · Cited by 38 · see citing works
Self-citationBionic Pancreas Research Group, Kruger, D., Kass, A., Lonier, J., Pettus, J., Raskin, P., Salam, M., Trikudanathan, S., Zhou, K., Russell, S. J., et al. (2022) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0200 · Cited by 38 · see citing works
Pfützner, A., Schipper, C., Niemeyer, M., Qvist, M., Löffler, A., Forst, T., & Musholt, P. B. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600423 · Cited by 37 · see citing works
A review of blood glucose monitor accuracy
King, F., Ahn, D., Hsiao, V., Porco, T., & Klonoff, D. C. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0232 · Cited by 37 · see citing works
Oppel, E. M., Kamann, S., Heinemann, L., Reichl, F., & Högg, C. (2019) · Contact Dermatitis · doi:10.1111/cod.13392 · Cited by 37 · see citing works
Flagged first, then by citations
Research works printed but not linked: 2
- Boughton, 2024, The effect of closed-loop glucose control on C-peptide secretion in youth with newly diagnosed type 1 diabetes: the CLOuD RCT, 8
- Chandran, 2015, Adherence to insulin pen therapy is associated with reduction in healthcare costs among patients with type 2 diabetes mellitus, Am Health Drug Benefits, 8, 148
Cited by
Sorted by citations
Semaglutide in Adults with Type 1 Diabetes and Obesity
Shah, V. N., Akturk, H. K., Kruger, D., Ahmann, A., Bhargava, A., Bakoyannis, G., Pyle, L., & Snell-Bergeon, J. K. (2025) · NEJM Evidence · doi:10.1056/evidoa2500173 · Cited by 62 · see citing works
Aronson, R., Abitbol, A., Bajaj, H. S., Cheng, A. Y. Y., Christopoulos, S., Harris, S. B., Jain, A. B., & Goldenberg, R. M. (2025) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.70008 · Cited by 33 · see citing works
Tumminia, A., Santoro, G. M., Oteri, V., Galeano, F., Baratta, R., Gullo, D., Frittitta, L., Sciacca, L., Moli, R. L., Piticchio, T., et al. (2025) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2025.112173 · Cited by 9 · see citing works
Diabetic gastroparesis: pathophysiology and impact on insulin timing choices
Galeano, F., Tumminia, A., Oteri, V., Le Moli, R., Piticchio, T., Scilletta, S., Di Marco, M., Di Pino, A., & Frasca, F. (2026) · Endocrine · doi:10.1007/s12020-026-04693-6
“These data facilitate a dynamic, iterative optimization of insulin dosing, bolus timing, and fractionation, moving away from purely empirical adjustments [132, 143, 145, 146].”
InfluentialClinical utility of the twiist Automated Insulin Delivery System: first study with twiist
Ruiz, A., Mcdonough, A., Snow, K., Bode, B., & Mitri, J. (2026) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2026-006307
- Authors
- American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., Ekhlaspour, L., Garg, R., Khunti, K., Lal, R., Lingvay, I., Matfin, G., Pandya, N., Pekas, E. J., Pilla, S. J., Polsky, S., Segal, A. R., Seley, J. J., Stanton, R. C., & Bannuru, R. R.
- ORCID
- ElSayed, Nuha A.
- McCoy, Rozalina G.
- Aleppo, Grazia
- Balapattabi, Kirthikaa
- Beverly, Elizabeth A.
- Briggs Early, Kathaleen
- Bruemmer, Dennis
- Echouffo-Tcheugui, Justin B.
- Ekhlaspour, Laya
- Garg, Rajesh
- Khunti, Kamlesh
- Lal, Rayhan
- Lingvay, Ildiko
- Pandya, Naushira
- Pekas, Elizabeth J.
- Pilla, Scott J.
- Polsky, Sarit
- Segal, Alissa R.
- Seley, Jane Jeffrie
- Stanton, Robert C.
- Bannuru, Raveendhara R.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2024-12-09
- Volume
- 48
- Issue
- Supplement_1
- Pages
- S146-S166
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- PMC
- PMC11635043
- OpenAlex
- W4405187548
- Semantic Scholar
- 247efba1a5237dc77552f3b09408f293abf81b6a
- Cited by
- 348
- References
- 292
- Citations by year
- 2026: 147 · 2025: 184 · 2024: 16 · 2023: 1
- FWCI
- 20.36
- Type
- journal article
- Language
- en
- Update notices
- correction (2025-02-23)
- Open access
- green
- pmc.ncbi.nlm.nih.gov
- Locations
- Diabetes Care (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute of Diabetes and Digestive and Kidney Diseases (K23DK121942)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Keywords
- diabetes technology, clinical guidelines, quality of care, treatment goals
- MeSH terms
- Diabetes Mellitus, Humans, Standard of Care
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Claims read by deepseek-v4.1-flash under definition version 3 (extract-v3) on 2026-10-05.
Classified by jev-1.13-20260917 (gold-guideline-v0.2) on 2026-10-05.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review