The DOI matches its Crossref record.
Analytical fractionation of complex lipid mixtures: DEAE cellulose column chromatography combined with quantitative thin layer chromatography
Abstract
A quantitative chromatographic procedure for the fractionation of complex lipid mixtures is described. The method utilizes diethylaminoethyl (DEAE) cellulose column chromatography followed by thin layer chromatography (TLC). Spots produced in TLC are charred with sulfuric acid‐potassium dichromate and heat and are then measured by quantitative densitometry. Results obtained with beef brain and beef heart mitochondrial lipids are presented, and the close correspondence between column isolation procedures and the new procedure is demonstrated. Methods utilizing only column chromatography, column chromatography and TLC, and one‐ and two‐dimensional TLC without column chromatography are compared.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Quantitative analysis of phospholipids by thin‐layer chromatography and phosphorus analysis of spots
Rouser, G., Siakotos, A. N., & Fleischer, S. (1966) · Lipids · doi:10.1007/bf02668129 · Cited by 1,574
Self-citationChemistry and metabolism of lipids in the vertebrate retina
Fliesler, A. J., & Anderson, R. E. (1983) · Progress in Lipid Research · doi:10.1016/0163-7827(83)90004-8 · Cited by 1,052
[54] Thin-layer chromatography of lipids
(1969) · Methods in Enzymology · doi:10.1016/s0076-6879(69)14056-2 · Cited by 573
Siakotos, A. N., & Rouser, G. (1965) · Journal of the American Oil Chemists' Society · doi:10.1007/bf02632444 · Cited by 429
Self-citationQuantitative densitometric thin-layer chromatography of lipids using copper acetate reagent
Fewster, M. E., Burns, B. J., & Mead, J. F. (1969) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)99173-8 · Cited by 403
Lipid composition of erythrocytes in various mammalian species
Nelson, G. J. (1967) · Biochimica et Biophysica Acta (BBA) - Lipids and Lipid Metabolism · doi:10.1016/0005-2760(67)90152-x · Cited by 314
Roughan, P. G., & Batt, R. D. (1968) · Analytical Biochemistry · doi:10.1016/0003-2697(68)90261-3 · Cited by 291
Lipid composition of mitochondria from bovine heart, liver, and kidney
Fleischer, S., Rouser, G., Fleischer, B., Casu, A., & Kritchevsky, G. (1967) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)40133-6 · Cited by 270
Self-citationLipid analysis by quantitative thin‐layer chromatography
Privett, O. S., Blank, M. L., Codding, D. W., & Nickell, E. C. (1965) · Journal of the American Oil Chemists' Society · doi:10.1007/bf02635573 · Cited by 172
Self-citation
Metadata
- Authors
- Rouser, G., Galli, C., Lieber, E., Blank, M. L., & Privett, O. S.
- Venue
- Journal of the American Oil Chemists' Society
- Publisher
- Wiley
- Published
- 1964-12
- Volume
- 41
- Issue
- 12
- Pages
- 836-840
- ISSN
- 0003-021X (ISSN-L)
- 1558-9331
- OpenAlex
- W1984166098
- Cited by
- 210
- References
- 0
- FWCI
- 15.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.