CoChat

Contour Tracking Using a Knowledge-Based Snake Algorithm to Construct Three-Dimensional Pharyngeal Bolus Movement

Chang, Michael W., Lin, Eugene, Hwang, Jenq-Neng · 1999 · Dysphagia

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

Videofluorography (VFG) using a barium-mixed bolus is in wide clinical use for assessing patients with swallowing disorders. VFG is usually done with both lateral (LA) and anterior-posterior (AP) views, most commonly in two separate sittings. A real-time, three-dimensional (3-D) representation of the evolution of a pharyngeal bolus and its volumetric information can potentially help clinicians analyze and visualize the kinematics of swallowing, dysphagia, and compensatory therapeutic strategies. Active contour models, also known as "Snakes," have been used to solve various image analysis and computer vision problems. We applied a Snake algorithm to automate in part the contour tracking and reconstruction of VFG images to visualize and quantitatively analyze the 3-D evolution of a pharyngeal bolus. To improve the accuracy of the Snake search, we provided the additional "knowledge" of the pharyngeal image itself, which served as an extra constraint to push the Snake curve toward the desired contour. VFG of pharyngeal bolus transport in a normal subject was recorded by using barium-mixed boluses (viscosity: 185 centipoise, density: 2.84 g/cc) with volumes of 5, 10, and 20 ml. The resulting LA and AP video images were digitally captured and matched frame by frame. The knowledge-based Snake search algorithm was used to generate Snake points to satisfy both internal (i.e., smoothness) and external (i.e., boundary fitting) constraints. Using these Snake points, we traced the 3-D bolus movement at each time instant, assuming elliptic geometry in the cross-section of the pharyngeal bolus. By concentrating the 3-D images for each time instant, we developed a 3-D movie representing pharyngeal bolus movement. The efficiency, reproducibility, and accuracy of this algorithm in tracing pharyngeal bolus boundaries and estimating front/tail velocities were assessed and found satisfactory. We conclude that 3-D pharyngeal bolus movement can be traced both accurately and efficiently by using a knowledge-based Snake search algorithm.

Overview

Integrity signals

Registry

Crossref · 10.1007/pl00009609

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 9 references

Cited by

Metadata

Authors
Chang, M. W., Lin, E., & Hwang, J.-N.
Affiliations
University of Washington (US)
Venue
Dysphagia
Published
1999-08
Volume
14
Issue
4
Pages
219-227
ISSN
0179-051X (ISSN-L)
OpenAlex
W2024818398
Cited by
14
References
9
Citations by year
2026: 1 · 2025: 1 · 2023: 1 · 2021: 1 · 2020: 1 · 2019: 1 · 2018: 1 · 2017: 1 · 2016: 1
FWCI
0.86
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • Dysphagia (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
  • Health Sciences › Health Professions › Speech and Hearing › Dysphagia Assessment and Management
  • Physical Sciences › Engineering › Biomedical Engineering › Medical Imaging and Analysis
Keywords
snakes, snake algorithm, videofluorography, swallowing kinematics, compensatory swallowing strategies
MeSH terms
Algorithms, Artificial Intelligence, Barium Sulfate, Cineradiography, Computer Simulation, Contrast Media, Deglutition, Deglutition Disorders, Fluoroscopy, Humans, Image Processing, Computer-Assisted, Pharynx, Radiographic Image Enhancement, Reproducibility of Results

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.