A new approach to computer-aided spine surgery: fluoroscopy-based surgical navigation
Open accessAbstract
A new computer-based navigation system for spinal surgery has been designed. This was achieved by combining intraoperative fluoroscopy-based imaging using conventional C-arm technology with free-hand surgical navigation principles. Modules were developed to automate digital X-ray image registration. This is in contrast to existing computed tomography- (CT) based spinal navigation systems, which require a vertebra-based registration procedure. Cross-referencing of the image intensifier with the surgical object allows the real-time image-interactive navigation of surgical tools based on one single registered X-ray image, with no further image updates. Furthermore, the system allows the acquisition and real-time use of multiple registered images, which provides an advanced multi-directional control (pseudo 3D) during surgical action. Stereotactic instruments and graphical user interfaces for image-interactive transpedicular screw insertion have been developed. A detailed validation of the system was performed in the laboratory setting and throughout an early clinical trial including eight patients in two spine centers. Based on the resulting data, the new technique promises improved accuracy and safety in open and percutaneous spinal surgery.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Intraoperative imaging techniques such as C-arm fluoroscopy or X-ray are important for localizing the greater trochanter, tracking and navigating the drilling and injection device to the femoral head, and positioning the trephine and scraping spoon while removing dead bone.
“Intraoperative imaging techniques such as C-arm fluoroscopy or X-ray have become important for the localization of the greater trochanter, tracking and navigation of the drilling and injection device to the femoral head, and positioning of the trephine and scraping spoon while removing the dead bones (Nolte et al. 2000; Geisert et al. 2017; Tian et al. 2021).”
From Towards 2D/3D Registration of the Preoperative MRI to Intraoperative Fluoroscopic Images for Visualisation of Bone Defects (2023) · cites this paper as Nolte et al. 2000
The Introduction and Surgical procedure sections describe C-arm fluoroscopy for navigating instruments during spinal pedicle-screw placement. They do not address the greater trochanter, femoral head, drilling or injection devices, or instruments for removing dead bone. Page numbers were not provided for these passages. (LLM, conf=0.88)
Experimental — accuracy not yet measuredImage-based navigation techniques do not require specialized equipment but rely on traditional intra-operative imaging.
“Image-based navigation techniques do not require specialized equipment but rely on traditional intra-operative imaging that enabled the minimally invasive technique in the first place.”
From The Impact of Machine Learning on 2D/3D Registration for Image-Guided Interventions: A Systematic Review and Perspective (2021) · cites this paper as Nolte et al., 2000
The Discussion says the system uses widely available C-arm fluoroscopy for intraoperative imaging. But the System components section describes an optoelectronic navigator, tracked instruments, and custom software, so the claim that it requires no specialized equipment is not supported. Page numbers are not provided in our copy. (LLM, conf=0.90)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 30 · Cited by 159
Research works printed but not linked: 9
- Brack C, Götte H, Gossè F, et al (1996) Towards accurate X-ray-camera cali- bration in computer-assisted robotic surgery. Proceedings of the Tenth In- ternational Symposium on Computer Assisted Radiology, pp 721-728
- Brandt G, Radermacher K, Lavallèe S, et al (1997) A compact robot for image guided orthopaedic surgery: concept and preliminary results. Proceedings of the First Joint Conference on Com- puter Vision, Virtual Reality, Medical Robotics and Computer Assisted Sur- gery, pp 767-776
- Cinquin P, Bainville E, Barbe C, et al (1995) Computer assisted medical in- terventions. IEEE Eng Med Biol 14: 254-263
- Foley KT, Smith MM, Abitbol JJ (1997) Thoracic pedicle screw place- ment accuracy: frameless stereotaxy versus conventional techniques. Pro- ceedings of the Symposium on Com- puter Assisted Orthopaedic Surgery - CAOS USA, pp 85-86
- Gembran KD, Thorpe CE, Kanade T (1988) Geometric camera calibration using systems of linear equations. Pro- ceedings of the IEEE International. Conference of Robotics and Automa- tion, pp 562-567
- Hamadeh A, Cinquin P (1997) Kine- matic study of lumbar spine using functional radiographs and 3D/2D reg- istration. Proceedings of the First Joint Conference on Computer Vision, Vir- tual Reality, Medical Robotics and Computer Assisted Surgery, pp 109- 118
- Hamadeh A, Sautot P, Lavallèe S, Cinquin P (1995) Towards automatic registration between CT and X-ray im- ages: cooperation between 3D/2D reg- istration and 2D edge detection. Pro- ceedings of the Second International Symposium on Medical Robotics and Computer Assisted Surgery, pp 39-46
- Krag MH (1991) Biomechanics of tho- racolumbar spinal fixation: a review. Spine 16: 84-99
- Lavallèe S, Troccaz J, Sautot P, et al (1996) Computer assisted spine sur- gery using anatomy-based registration. In: Taylor R, Lavallèe S, Burdea G, Moesges R (eds) Computer integrated surgery. MIT Press, Cambridge, pp 425-449
- Authors
- Nolte, L. P., Slomczykowski, M. A., Berlemann, U., Strauss, M. J., Hofstetter, R., Schlenzka, D., Laine, T., & Lund, T.
- Affiliations
- University of Bern (CH)
- University Medical Center Hamburg-Eppendorf (DE)
- Tekonivelsairaala Orton (FI)
- Venue
- European Spine Journal
- Published
- 2000-02-25
- Volume
- 9
- Issue
- S1
- Pages
- S078-S088
- ISSN
- 0940-6719 (ISSN-L)
- PMC
- PMC3611449
- OpenAlex
- W2064673484
- Cited by
- 159
- References
- 30
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 4 · 2023: 3 · 2022: 6 · 2021: 2 · 2019: 2 · 2018: 4 · 2017: 2 · 2016: 2 · 2015: 3 · 2014: 5 · 2013: 5 · 2012: 8
- FWCI
- 11.54
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- www.springer.com/tdm (tdm)
- Locations
- European Spine Journal (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Kommission für Technologie und Innovation
- Topics
- Health Sciences › Medicine › Surgery › Spinal Fractures and Fixation Techniques
- Physical Sciences › Engineering › Biomedical Engineering › Medical Imaging and Analysis
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Keywords
- surgical navigation, intraoperative fluoroscopy, C-arm imaging, image registration, image intensifier, open spine surgery
- MeSH terms
- Bone Screws, Equipment Design, Female, Fluoroscopy, Humans, Male, Orthopedic Equipment, Spine, Therapy, Computer-Assisted, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review