kV Cone-Beam CT-Based IGRT: A Clinical Review
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
AbstractAims and Methods:Delivery of high radiation doses while simultaneously sparing organs at risk requires advanced imaging for target volume definition, highly conformal dose distributions of intensity modulated radiotherapy (IMRT), and narrow planning target volume (PTV) margins. Three-dimensional image-guided radiotherapy (IGRT) with cone-beam computer tomography (CBCT), which results in more precise target localization, is quickly replacing two-dimensional (2D) IGRT. An overview on the clinical applications of kilovoltage gantry-mounted CBCT systems with emphasis on the most frequently targeted body sites (prostate, lung, head and neck) is provided based on a review of the relevant literature. Alternative imaging methods and their advantages/disadvantages are discussed.Results:IGRT with soft tissue detection improves set-up accuracy and is currently replacing 2D verification and frame-based stereotactic treatments; safety margins are significantly reduced by this IGRT technology. In addition, systematic changes of tumor volume and shape and of the normal tissue can be monitored allowing for adaptation of radiotherapy. IGRT in combination with conformal treatment planning allows for hypofractionated dose escalation, which results in improved rates of local tumor control with low rates of toxicity.Conclusion:CBCT allows for daily pretreatment position verification and online correction of set-up errors which improves the precision of patient repositioning with the possibility of shrinking safety margins, sparing organs at risk, and escalating radiation doses. A trend for better clinical outcome can be observed.ZusammenfassungHintergrund und Methodik:Die Verwendung von eskalierten Bestrahlungsdosen bei gleichzeitiger Schonung der Risikoorgane setzt multimodale Bildgebung zur Zielvolumendefinition, hochkonformale Bestrahlungsplanung mittels intensitätsmodulierter Radiotherapie und enge Sicherheitssäume voraus. Bildgeführte Strahlentherapie (IGRT) dient der präzisen Lokalisation des Zielvolumens, und konventionelle 2D Techniken wie Feldkontrollaufnahmen werden aktuell insbesondere durch dreidimensionale Cone-beam-(CBCT-)Technik ersetzt. Dieser Artikel gibt einen Literaturüberblick über den aktuellen Stand der IGRT mittels CBCT. Schwerpunkte sind die praktische Anwendung und klinischen Resultate bei Prostatakarzinom, Bronchialkarzinom und Kopf-Hals-Tumoren. Ergebnisse: Schlussfolgerungen: Schlüsselwörter: Ergebnisse:IGRT mittels CBCT ist hocheffektiv zur Verifikation der Patientenpositionierung und insbesondere zur Verifikation der Tumorposition. Rahmenbasierte Stereotaxie kann durch IGRT ersetzt werden, sowohl kraniell als auch extrakraniell. Bei Verwendung von IGRT-Techniken ohne ausreichenden Weichteilkontrast müssen größere Sicherheitssäume verwendet werden, um ein Verfehlen des Zielvolumens zu vermeiden. Zusätzlich sind mittels 3D IGRT systematische Veränderungen von Tumorvolumen, Tumorform und Lagebeziehung zu Risikoorganen darstellbar, was zur Adaption des Bestrahlungsplanes genutzt werden kann. Mittels konformaler IMRT-Bestrahlungstechniken und präziser IGRT konnten hypofraktionierte, eskalierte Bestrahlungsdosen sicher appliziert werden, was in verbesserter lokaler Tumorkontrolle ohne erhöhte Toxizität resultierte.Schlussfolgerungen:CBCT ermöglicht die Verifikation der Tumorposition zur Online-Korrektur von Positionsfehlern vor der Behandlung, was die Anwendung von kleinen Sicherheitssäumen, Normalgewebsschonung und Dosiseskalation ermöglicht. Die Verbesserung klinischer Ergebnisse wird durch diese Techniken erwartet und ist z.T. bereits in der Literatur dokumentiert.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Long-term results of the M.D. Anderson randomized dose-escalation trial for prostate cancer
Kuban, D. A., Tucker, S. L., Dong, L., Starkschall, G., Huang, E. H., Cheung, M. R., Lee, A. K., & Pollack, A. (2008) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2007.06.054 · Cited by 1,232
Zietman, A. L., DeSilvio, M. L., Slater, J. D., Rossi, C. J., Miller, D. W., Adams, J. A., & Shipley, W. U. (2005) · JAMA · doi:10.1001/jama.294.10.1233 · Cited by 1,224 · cited 1×
“2 Gy [2, 18, 44, 84].”
Cited by
TIGRE: a MATLAB-GPU toolbox for CBCT image reconstruction
Biguri, A., Dosanjh, M., Hancock, S., & Soleimani, M. (2016) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/2/5/055010 · Cited by 370
Deep Inspiration Breath Hold—Based Radiation Therapy: A Clinical Review
Boda-Heggemann, J., Knopf, A.-C., Simeonova-Chergou, A., Wertz, H., Stieler, F., Jahnke, A., Jahnke, L., Fleckenstein, J., Vogel, L., Arns, A., et al. (2016) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2015.11.049 · Cited by 247
Self-citationSynthetic CT generation from CBCT images via deep learning
Chen, L., Liang, X., Shen, C., Jiang, S., & Wang, J. (2020) · Medical Physics · doi:10.1002/mp.13978 · Cited by 201
“Image-guided radiation therapy , which uses frequent imaging during a course of radiation therapy, has been widely used to improve precision and accuracy of radiation treatment delivery 1,2 .”
MethodDeep learning based synthetic‐CT generation in radiotherapy and PET: A review
Spadea, M. F., Maspero, M., Zaffino, P., & Seco, J. (2021) · Medical Physics · doi:10.1002/mp.15150 · Cited by 201
Metadata
- Authors
- Boda-Heggemann, J., Lohr, F., Wenz, F., Flentje, M., & Guckenberger, M.
- Venue
- Strahlentherapie und Onkologie
- Published
- 2011-04-26
- Volume
- 187
- Issue
- 5
- Pages
- 284-291
- ISSN
- 0179-7158 (ISSN-L)
- 1439-099X
- OpenAlex
- W166308433
- Cited by
- 211
- References
- 2
- FWCI
- 22.88
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: kV Cone-Beam CT-Based IGRT: A Clinical Review. https://app.cochat.ai/papers/10.1007/s00066-011-2236-4
- The paper
- Boda-Heggemann, J., Lohr, F., Wenz, F., Flentje, M., & Guckenberger, M. (2011). kV Cone-Beam CT-Based IGRT: A Clinical Review. Strahlentherapie und Onkologie. https://doi.org/10.1007/s00066-011-2236-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.