The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Self-monitoring of blood glucose in type 2 diabetes and long-term outcome: an epidemiological cohort study
Open accessAbstract
Aims/hypothesis The aim of this study was to obtain epidemiological data on self-monitoring of blood glucose (SMBG) in type 2 diabetes and to investigate the relationship of SMBG with disease-related morbidity and mortality.Methods The German multicentre Retrolective Study 'Self-monitoring of Blood Glucose and Outcome in Patients with Type 2 Diabetes' (ROSSO) followed 3,268 patients from diagnosis of type 2 diabetes between 1995 and 1999 until the end of 2003. Endpoints were diabetes-related morbidity (non-fatal myocardial infarction, stroke, foot amputation, blindness or haemodialysis) and all-cause mortality. SMBG was defined as self-measurement of blood glucose for at least 1 year.Results During a mean follow-up period of 6.5 years, 1,479 patients (45.3%) began SMBG prior to an endpoint and an additional 64 patients started SMBG after a non-fatal endpoint. Interestingly, many patients used SMBG while being treated with diet or oral hypoglycaemic drugs (808 of 2,515, 32%). At baseline, the SMBG cohort had higher mean fasting blood glucose levels than the non-SMBG cohort (p<0.001), suggesting that insufficient metabolic control was one reason for initiating SMBG. This was associated with a higher rate of microvascular endpoints. However, the total rate of non-fatal events, micro- and macrovascular, was lower in the SMBG group than in the non-SMBG group (7.2 vs 10.4%, p=0.002). A similar difference was found for the rate of fatal events (2.7 vs 4.6%, p=0.004). Cox regression analysis identified SMBG as an independent predictor of morbidity and mortality, with adjusted hazard ratios of 0.68 (95% CI 0.51-0.91, p=0.009) and 0.49 (95% CI 0.31-0.78, p=0.003), respectively. A better outcome for both endpoints was also observed in the SMBG cohort when only those patients who were not receiving insulin were analysed.Conclusions/interpretation SMBG was associated with decreased diabetes-related morbidity and all-cause mortality in type 2 diabetes, and this association remained in a subgroup of patients who were not receiving insulin therapy. SMBG may be associated with a healthier lifestyle and/or better disease management.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For individuals with type 2 diabetes, cross-sectional and longitudinal observational studies in several countries have failed to demonstrate an improvement in glycemic control (as measured by mean HbA 1c concentration) associated with the use of SMBG (102-104).”
From Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus (2011) · cites this paper as [104]
In the citing paper
“Frequency of meter use did not predict HbA 1c .”
From Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus (2011) · cites this paper as [104]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Turner, R. C., Fox, C., Matthews, McElroy, H. H., Cull, C. A., Holman, R. R., Neil, P., Hadden, D. R., Wright, D., Manley, E., et al. (1998) · The Lancet · Cited by 8,419
Gupta, A., & Uribarri, J. (2016) · Hormone Research in Paediatrics · doi:10.1159/000444053 · Cited by 4,023
External validity of randomised controlled trials: “To whom do the results of this trial apply?”
Rothwell, P. M. (2005) · The Lancet · doi:10.1016/s0140-6736(04)17670-8 · Cited by 2,544
Socioeconomic Status in Health Research
Braveman, P., Cubbin, C., Egerter, S. A., Chideya, S., Marchi, K. S., Metzler, M. M., & Posner, S. F. (2005) · JAMA · doi:10.1001/jama.294.22.2879 · Cited by 2,360
American Diabetes Association (2003) · Diabetes Care · doi:10.2337/diacare.26.2007.s106 · Cited by 1,037
Karter, A. J., Ackerson, L. M., Darbinian, J. A., D’Agostino, R. B., Ferrara, A., Liu, J., & Selby, J. V. (2001) · The American Journal of Medicine · doi:10.1016/s0002-9343(01)00742-2 · Cited by 595
Aubert, R. E., Herman, W. H., Waters, J., Moore, W., SUTTON, D. R., Peterson, B. L., Bailey, C. M., & Koplan, J. P. (1998) · Annals of Internal Medicine · doi:10.7326/0003-4819-129-8-199810150-00004 · Cited by 561
Rathmann, W., Haastert, B., Icks, A., Löwel, H., Meisinger, C., Holle, R., & Giani, G. (2003) · Diabetologia · doi:10.1007/s00125-002-1025-0 · Cited by 547
Ismail, K., Winkley, K., & Rabe-Hesketh, S. (2004) · The Lancet · doi:10.1016/s0140-6736(04)16202-8 · Cited by 531
Flagged first, then by citations
Cited by
Sorted by citations
Items 101–200 of 284
Assessment of Postprandial Glucose Excursions Throughout the Day in Newly Diagnosed Type 2 Diabetes
Cichosz, S. L., Fleischer, J., Høyem, P., Laugesen, E., Poulsen, P. L., Christiansen, J. S., Ejskjær, N., & Hansen, T. K. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2012.0199 · Cited by 24
Parchman, M. L., & Kaissi, A. A. (2009) · The Joint Commission Journal on Quality and Patient Safety · doi:10.1016/s1553-7250(09)35017-5 · Cited by 22
György, J., Gaál, Z., Gerő, L., Hídvégi, T., Kempler, P., Winkler, G., & Wittmann, I. (2017) · Diabetologia Hungarica · doi:10.24121/dh.2017.1 · Cited by 23
Grunberger, G., Bailey, T. S., Camacho, P. M., EINHORN, D. F., Garber, A. J., Handelsman, Y., Harrell, R. M., Lando, H. M., Law, B., Leffert, J. D., et al. (2015) · Endocrine Practice · doi:10.4158/ep15653.cs · Cited by 21
A New Test Strip Technology Platform for Self-Monitoring of Blood Glucose
Bernstein, R., Parkes, J. L., Goldy, A., Brown, D., Harrison, B., Chu, A., Pflug, B. K., Simmons, D. A., Pardo, S. A., & Bailey, T. S. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700531 · Cited by 21
Zhang, Y., Xu, H., Wang, T., He, J., Qiao, Y., Wei, J., & Dong, J. (2015) · PLOS ONE · doi:10.1371/journal.pone.0144410 · Cited by 19
Economic and Clinical Aspects of Diabetes Regarding Self-Monitoring of Blood Glucose
Schnell, O., Hummel, M., & Weber, C. (2008) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0017 · Cited by 20
Patel, V., Saha, D., Kruse, P., & Selvaganapathy, P. R. (2022) · ACS Applied Nano Materials · doi:10.1021/acsanm.1c04540 · Cited by 19
Hsieh, C., Huang, I.-C., Wang, P.-W., Liu, R., Tung, S., Chen, J., & Kuo, M. (2012) · Biomedical Journal · doi:10.4103/2319-4170.106167 · Cited by 18
Bigelow, M. E., Jamieson, B. G., Chui, C. O., Mao, Y., Shin, K.-S., Huang, T. J., Huang, P., Ren, L., Adhikari, B. B., Chen, J., et al. (2016) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2016.2593920 · Cited by 18
The role of blood glucose monitoring in non-insulin treated type 2 diabetes: What is the evidence?
Benhalima, K., & Mathieu, C. (2012) · Primary care diabetes · doi:10.1016/j.pcd.2012.05.001 · Cited by 18
Gerich, J. E., Odawara, M., & Terauchi, Y. (2007) · Current Medical Research and Opinion · doi:10.1185/030079907x210660 · Cited by 23
Kolb, H., Schneider, B., Heinemann, L., Heise, T., Lodwig, V., Tshiananga, J. K. T., Weber, C., Scherbaum, W. A., & Martin, S. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200112 · Cited by 18
Self-citationMühlbacher, A. C., Sadler, A., & Juhnke, C. (2021) · The European Journal of Health Economics · doi:10.1007/s10198-021-01264-6 · Cited by 16
Aghili, R., Khamseh, M. E., Malek, M., Yarahmadi, S., & Farshchi, A. (2012) · DARU Journal of Pharmaceutical Sciences · doi:10.1186/2008-2231-20-32 · Cited by 16
Clinical Evaluation of a Photonic Crystal Sensor for Glucose Monitoring in Urine
Lan, Y., Xue, M., Qiu, L., & Meng, Z. (2019) · ChemistrySelect · doi:10.1002/slct.201900840 · Cited by 16
Neeser, K., & Weber, C. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0139 · Cited by 16
Martin, S., Kolb, H., Schneider, B., Heinemann, L., Weber, C., Kocher, S., Tshiananga, J. K. T., Scherbaum, W. A., & Lodwig, V. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0062 · Cited by 16
Self-citationSelf-reported compliance with osteoporosis medication—Qualitative aspects and correlates
Vytrisalova, M., Blazkova, S., Palička, V., Vlček, J., Cejkova, M., Hala, T., Pavelká, K., & Koblihová, H. Š. (2008) · Maturitas · doi:10.1016/j.maturitas.2008.07.009 · Cited by 16
Müller, U., Hämmerlein, A., Casper, A., & Schulz, M. (2006) · Pharmacy Practice · doi:10.4321/s1885-642x2006000400008 · Cited by 15
Mangrola, D., Cox, C., Furman, A. S., Krishnan, S., & Karakas, S. E. (2017) · Endocrine Practice · doi:10.4158/ep-2017-0032 · Cited by 17
Self-monitoring of blood glucose with a focus on analytical quality: an overview
Kristensen, G. B. B., & Sandberg, S. (2010) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2010.186 · Cited by 16
BOEDER, S. C., Matamoros, D., & Mansy, C. (2022) · Diabetes Therapy · doi:10.1007/s13300-022-01330-z · Cited by 15
B. Davidson, M. (2010) · Reviews on Recent Clinical Trials · doi:10.2174/157488710792007248 · Cited by 15
Kim, S. K., Hahm, J. R., Kim, H., Kim, S., Jung, T. S., Jung, J. H., Lee, H. R., & Kim, D. R. (2013) · Yonsei Medical Journal · doi:10.3349/ymj.2013.54.5.1289 · Cited by 15
Self monitoring of blood glucose in type 2 diabetes
Heller, S. R. (2007) · BMJ · doi:10.1136/bmj.39276.549109.47 · Cited by 15
Bailey, T., Wallace, J. F., Greene, C., Pardo, S., Brown, D., Pflug, B., & Klaff, L. J. (2015) · Clinica Chimica Acta · doi:10.1016/j.cca.2015.06.001 · Cited by 14
Bidirectional association between depression and diabetic nephropathy by meta-analysis
Fang, T., Zhang, Q., Wang, Z., & Liu, J. (2022) · PLoS ONE · doi:10.1371/journal.pone.0278489 · Cited by 14
Consensus guidelines for glycemic monitoring in type 1/type 2 & GDM
Kesavadev, J., SADIKOT, S. M., WANGNOO, S. K., Kannampilly, J., Saboo, B., Aravind, S. R., Kalra, S., Makkar, B. M., Maji, D., Saikia, M., et al. (2014) · Diabetes & Metabolic Syndrome Clinical Research & Reviews · doi:10.1016/j.dsx.2014.04.030 · Cited by 14
Nauck, M. A., Haastert, B., Trautner, C., Müller, U., Nauck, M. A., & Heinemann, L. (2014) · Diabetologia · doi:10.1007/s00125-014-3168-1 · Cited by 15
Self-citationTunis, S. L. (2011) · Applied Health Economics and Health Policy · doi:10.2165/11594270-000000000-00000 · Cited by 13
SELF-TREATMENT WITH ANTI-OBESITY MEDICATIONS IN OVERWEIGHT AND OBESE WOMEN IN TEHRAN-IRAN
Fazelian, S., Namazi, N., & Heshmati, J. (2014) · Cited by 13
The Accuracy and Interferences in Self-monitoring of Blood Glucose
Bode, B. W., & Diabetes Specialist, A. D. A. (2007) · US Endocrinology · doi:10.17925/use.2007.00.2.46 · Cited by 12
Freckmann, G., Baumstark, A., Jendrike, N., Mende, J., Schauer, S., Link, M., Pleus, S., & Haug, C. (2022) · Journal of Diabetes Science and Technology · doi:10.1177/1932296820948873 · Cited by 12
Sun, X., Zhou, X., Li, S., & Ji, L. (2023) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2023.111027 · Cited by 11
Patient self-testing in chronic disease management
O’Kane, M. (2019) · Journal of Laboratory Medicine · doi:10.1515/labmed-2019-0175 · Cited by 13
Muller, N., Stengel, Kloos, Ristow, M., Wolf, & Müller, U. (2012) · International Journal of General Medicine · doi:10.2147/ijgm.s28505 · Cited by 12
Yaghoubi, M., Mansell, K. D., Vatanparast, H., Steeves, M., Zeng, W., & Farag, M. (2019) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2019.09.001 · Cited by 12
Self-Measurement of Blood Glucose in Patients with Type 2 Diabetes: A Health Economic Assessment
Weber, C., Neeser, K., Schneider, B., & Lodwig, V. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100511 · Cited by 12
Self-citationThe Importance of Monitoring Blood Glucose
Gavin, J. R. (2007) · US Endocrinology · doi:10.17925/use.2007.00.2.42 · Cited by 12
Bedros, J. R., Jermendy, G., Gaál, Z., Gerő, L., Hídvégi, T., Kempler, P., Lengyel, C., Várkonyi, T. T., Winkler, G., & Wittmann, I. (2023) · Diabetologia Hungarica · doi:10.24121/dh.2023.20 · Cited by 18
Tesfaye, D., Tessema, F., & Taha, M. (2015) · OALib · doi:10.4236/oalib.1101218 · Cited by 11
Nadkarni, A., Kucukarslan, S. N., Bagozzi, R. P., Yates, J. F., & Erickson, S. R. (2010) · Patient Education and Counseling · doi:10.1016/j.pec.2010.09.027 · Cited by 11
Kolb, H., Schneider, B., Heinemann, L., Lodwig, V., Scherbaum, W. A., & Martin, S. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100406 · Cited by 11
Self-citationThe dilemma of self-monitoring of blood glucose
Davidson, M. B. (2007) · Diabetologia · doi:10.1007/s00125-006-0582-z · Cited by 11
YEUNG, Y. L., Lee, K. Y., Lau, E. S. H., Yung, T.-F., Yang, A., Wu, H., Wong, K. T., Kong, A. P. S., Chow, E., Ronald, C. W., et al. (2024) · Frontiers in Endocrinology · doi:10.3389/fendo.2024.1284799 · Cited by 10
Baltacı, D., Kutlucan, A., Öztürk, S., Sarıtaş, A., Çeler, A., Celbek, G., Deler, M. H., Aydın, Y., & Ankaralı, H. Ç. (2012) · PubMed · Cited by 10
Vitale, R. J., Pillai, P. B. S., Krishnan, G., Jothydev, S., & Kesavadev, J. (2015) · Diabetes & Metabolic Syndrome Clinical Research & Reviews · doi:10.1016/j.dsx.2015.09.025 · Cited by 10
Chubb, S. A. P., Minnen, K. V., Davis, W. A., Bruce, D. G., & Davis, T. M. E. (2011) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2011.07.038 · Cited by 11
Yoo, W. S., Min, J. W., Chung, P., & Woo, S. H. (2020) · Lasers in Surgery and Medicine · doi:10.1002/lsm.23298 · Cited by 11
Weber, C., Kocher, S., Neeser, K., & Bartášková, D. (2009) · Current Medical Research and Opinion · doi:10.1185/03007990903479224 · Cited by 10
Performance of a New Blood Glucose Monitoring System in the Hands of Intended Users
Bailey, T. S., Wallace, J. F., Parkes, J. L., Pardo, S. A., Yu, J. H., Schachner, H. C., Simmons, D. A., & Chu, A. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2012.0046 · Cited by 9
Can blood glucose self-monitoring improve treatment outcomes in type 2 diabetes?
Varanauskienė, E. (2008) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2008.09.025 · Cited by 9
Self-Monitoring of Blood Glucose in Insulin-Requiring Type 2 Diabetes
Naik, R. G., & Ellis, S. L. (2008) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0030 · Cited by 9
Behandlung von Migrantinnen und Migranten mit Diabetes
Kalvelage, B., & Kofahl, C. (2013) · Springer eBooks · doi:10.1007/978-3-642-29908-7_7 · Cited by 9
Self-Monitoring of Blood Glucose in Diabetes Mellitus
Nauck, M. A., El-Ouaghlidi, A., & Vardarli, I. (2009) · Deutsches Ärzteblatt international · doi:10.3238/arztebl.2009.0587 · Cited by 11
Cost of type 2 diabetes in Germany over 8 years (the ROSSO study No. 2)
Weber, C., Neeser, K., Wenzel, H., & Schneider, B. (2006) · Journal of Medical Economics · doi:10.3111/200609045053 · Cited by 9
Self-citationKolb, H., Schneider, B., Heinemann, L., Lodwig, V., & Martin, S. (2006) · Diabetes Care · doi:10.2337/dc06-1916 · Cited by 9
Self-citationBlutzuckerselbstkontrolle Update 2023
Wascher, T. C., Stechemesser, L., Harreiter, J., & Leitlinien, A. (2023) · Wiener klinische Wochenschrift · doi:10.1007/s00508-023-02172-w · Cited by 8
Xie, Y., Agiro, A., Bowman, K. M., & DEVRIES, A. R. (2017) · Journal of Managed Care & Specialty Pharmacy · doi:10.18553/jmcp.2017.23.8.884 · Cited by 9
Simulation of a multi-strip blood glucometer
Anoop, A. E., Mohan, N. M., & Guruvayurappan, K. (2014) · IEEE Region 10 Conference (TENCON) · doi:10.1109/tencon.2014.7022473 · Cited by 8
Long-Term Conditions: Nursing Care and Management
Meerabeau, L., & Wright, K. (2011) · Andalas University Repository (Andalas University) · Cited by 8
Wascher, T. C., & Stechemesser, L. (2016) · Wiener klinische Wochenschrift · doi:10.1007/s00508-015-0927-z · Cited by 7
Moradi, S., Sahebi, Z., Valojerdi, A. E., Rohani, F., & Ebrahimi, H. (2017) · PLoS ONE · doi:10.1371/journal.pone.0179190 · Cited by 7
Yang, X., Lu, J., Weng, J., Gu, W., Guo, X., Zou, D., Zhou, Z., Zhu, D., Ji, Q., Ji, L., et al. (2014) · Patient Preference and Adherence · doi:10.2147/ppa.s66915 · Cited by 7
Hoffmann, F., & Andersohn, F. (2010) · Diabetologia · doi:10.1007/s00125-010-1909-3 · Cited by 7
Ascensia® WinGLUCOFACTS® Professional Software Improves Diabetes Health Outcomes
Janssen, M., Portalatin, M. E., Wallace, J. F., Zhong, W., & Parkes, J. L. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100108 · Cited by 7
Madeo, B., Diazzi, C., Granata, A. R. M., Ghoch, M. E., Greco, C., Romano, S., Scaltriti, S., & Rochira, V. (2020) · Journal of Population Therapeutics and Clinical Pharmacology · doi:10.15586/jptcp.v27isp2.680 · Cited by 7
Implementation plans and self-monitoring of blood glucose in diabetics
Nadkarni, A. (2009) · Deep Blue (University of Michigan) · Cited by 7
Meyer, G., & Mühlhauser, I. (2006) · Diabetologia · doi:10.1007/s00125-006-0252-1 · Cited by 7
Niitsu, K., Fukushima, K., Hiraoka, Y., Urawa, H., Ozawa, Y., Osaki, Y., Kaneko, M., Nakamura, J., & Yoshikawa, H. (2024) · IEEE Latin American Symposium on Circuits and Systems (LASCAS) · doi:10.1109/lascas60203.2024.10506119 · Cited by 6
Parkes, J. L., Harrison, B., & Pardo, S. A. (2012) · Diabetes Management · doi:10.2217/dmt.12.69 · Cited by 6
Effect of Subcutaneous Glucose Sensor Implantation on Skin mRNA Expression in Pigs
Kvist, P. H., Iburg, T. M., Dawson, H. D., & Jensen, H. E. (2010) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2010.0041 · Cited by 6
Future directions for insulin therapy and diabetes treatment
Heinemann, L. (2007) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/s0889-8529(07)80012-0 · Cited by 6
Self-citationSchnell, O., & Heinemann, L. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100503 · Cited by 6
Self-citationAADE Guidelines for the Practice of Diabetes Self-Management Education/Training (DSME/T)
Parkin, C., Hinnen, D., Turner, M. B., & Lumber, T. (2009) · Cited by 5
Wen, X., Zeng, N., Zhang, N., Ou, T., Li, X., Li, X., Li, W., Xu, K., & Du, T. (2022) · Diabetes Metabolic Syndrome and Obesity · doi:10.2147/dmso.s381565 · Cited by 5
Sheu, W. H. (2012) · Journal of Diabetes Investigation · doi:10.1111/j.2040-1124.2012.00216.x · Cited by 5
Diabetes self-care maintenance, comorbid conditions and perceived health
Song, M., & Lee, C. S. (2009) · European Diabetes Nursing · doi:10.1002/edn.137 · Cited by 5
Al-Tamimi, N., Slater, N., Kayyali, R., & ElShaer, A. (2018) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2018.02.005 · Cited by 5
Self-monitoring of Blood Glucose in Individuals with Type 2 Diabetes Not Using Insulin: Commentary
Woo, V. C., CHENG, A. Y. Y., Hanna, A., & Berard, L. (2010) · Canadian Journal of Diabetes · doi:10.1016/s1499-2671(10)41003-5 · Cited by 5
Age-dependent difference in factors affecting choice of system for self-monitoring of blood glucose
Fujisawa, T., Ikegami, H., Kasayama, S., Matsuhisa, M., Yamasaki, Y., Miyagawa, J., Funahashi, T., & Shimomura, I. (2007) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2007.08.012 · Cited by 5
Förderung der eigenverantwortlichen Therapie bei Typ-2-Diabetes
Lange, K. (2006) · Der Diabetologe · doi:10.1007/s11428-006-0077-z · Cited by 5
Schiel, R., Netzer, C., Junghänel, J., & Müller, U. (2009) · Zeitschrift für Evidenz Fortbildung und Qualität im Gesundheitswesen · doi:10.1016/j.zefq.2009.07.006 · Cited by 4
Agborsangaya, C. B., Robitaille, C., Dunbar, P., Langlois, M., Leiter, L. A., Dai, S., Pelletier, C., & Johnson, J. A. (2013) · PubMed · Cited by 4
Mamykina, L., Levine, M. E., Davidson, P. G., Smaldone, A. M., Elhadad, N., & Albers, D. J. (2017) · Health informatics · doi:10.1007/978-3-319-51732-2_14 · Cited by 5
The methodology of glucose monitoring in type 2 diabetes mellitus.
Gribovschi, M. (2013) · Europe PMC (PubMed Central) · Cited by 4
Ćaćić, M., Kruljac, I., Mirošević, G., & Vrkljan, M. (2020) · Clinical Diabetology · doi:10.5603/dk.2020.0054 · Cited by 4
Mosli, H. H., & Madani, B. (2021) · International Journal of Medicine in Developing Countries · doi:10.24911/ijmdc.51-1611360395 · Cited by 4
Self‐monitoring of blood glucose for type 2 diabetes
Bloomgarden, Z. T., & Ning, G. (2015) · Journal of Diabetes · doi:10.1111/1753-0407.12307 · Cited by 4
Mohr, T., Pfützner, A., Forst, S., Forst, T. M., & Schöndorf, T. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100110 · Cited by 4
L’autosurveillance glycémique au cours du diabète de type 2 non insulinotraité : le contre !
Halimi, S. (2008) · Médecine des Maladies Métaboliques · doi:10.1016/s1957-2557(08)74045-8 · Cited by 4
Perfetti, R. (2013) · Diabetes Management · doi:10.2217/dmt.13.51 · Cited by 4
Association between Sitagliptin Adherence and Self-Monitoring of Blood Glucose
Nigam, S., Virdi, N. S., Daskiran, M., Kozma, C. M., Paris, A., & Dickson, W. M. (2012) · Journal of Diabetes Science and Technology · doi:10.1177/193229681200600310 · Cited by 4
Self-monitoring of blood glucose in diabetes
(2007) · Drug and Therapeutics Bulletin · doi:10.1136/dtb.2007.45965 · Cited by 4
Kolb, H., Martin, S., Lodwig, V., Heinemann, L., Scherbaum, W. A., & Schneider, B. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300633 · Cited by 4
Self-citationLangová, K., Přibylová, H., Kajabová, M., & Luza, J. (2009) · Biomedical Papers · doi:10.5507/bp.2009.023 · Cited by 4
Self-Monitoring of Blood Glucose in the Asia-Pacific Region
Joshi, S. R. (2008) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0014 · Cited by 3
Performance and User Experience Evaluation of a Non-Invasive Glucose Monitoring Device
(2016) · International Journal of Diabetes & Metabolic Disorders · doi:10.33140/ijdmd/00009 · Cited by 3
Krishnan, G., & Raghuram, J. N. V. (2024) · International Journal of Pharmaceutical and Healthcare Marketing · doi:10.1108/ijphm-06-2023-0044 · Cited by 3
Metadata
- Authors
- Martin, S., Schneider, B., Heinemann, L., Lodwig, V., Kurth, H.-J., Kolb, H., Scherbaum, W. A., & for the ROSSO Study Group
- Affiliations
- Deutsches Diabetes-Zentrum e.V. (DE)
- Medizinische Hochschule Hannover (DE)
- Profil Institute for Metabolic Research (DE)
- Institute for Medical Informatics and Biostatistics (CH)
- Corresponding author
- Martin, S.
- Venue
- Diabetologia
- Published
- 2005-12-17
- Volume
- 49
- Issue
- 2
- Pages
- 271-278
- ISSN
- 0012-186X (ISSN-L)
- 1432-0428
- OpenAlex
- W2142280025
- Cited by
- 284
- References
- 40
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 8 · 2023: 7 · 2022: 8 · 2021: 5 · 2020: 11 · 2019: 11 · 2018: 6 · 2017: 16 · 2016: 7 · 2015: 13 · 2014: 19 · 2013: 13 · 2012: 21
- FWCI
- 14.69
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Diabetologia (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Bundesministerium für Bildung und Forschung
- Bundesministerium für Gesundheit
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Keywords
- self-monitoring of blood glucose, type 2 diabetes, all-cause mortality, microvascular complications, macrovascular complications, glycemic control, fasting blood glucose, insulin therapy, oral antidiabetic drugs, myocardial infarction, stroke, foot amputation, blindness
- MeSH terms
- Aged, Blood Glucose, Diabetes Mellitus, Type 2, Female, Follow-Up Studies, Humans, Hypoglycemic Agents, Insulin, Longitudinal Studies, Male, Middle Aged, Regression Analysis, Retrospective Studies, Blood Glucose Self-Monitoring, Cohort Studies, Survival Analysis, Outcome Assessment, Health Care, Disease Management, Diabetes Complications
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review