Effectiveness of continuous glucose monitoring in maintaining glycaemic control among people with type 1 diabetes mellitus: A systematic review of randomised controlled trials and meta-analysis
Open accessAbstract
Aims/hypothesis The aim of this work was to assess the effectiveness of continuous glucose monitoring (CGM) vs self-monitoring of blood glucose (SMBG) in maintaining glycaemic control among people with type 1 diabetes mellitus.Methods Cochrane Library, PubMed, Embase, CINAHL, Scopus, trial registries and grey literature were searched from 9 June 2011 until 22 December 2020 for RCTs comparing CGM intervention against SMBG control among the non-pregnant individuals with type 1 diabetes mellitus of all ages and both sexes on multiple daily injections or continuous subcutaneous insulin infusion with HbA 1c levels, severe hypoglycaemia and diabetic ketoacidosis (DKA) as outcomes. Studies also included any individual or caregiver-led CGM systems. Studies involving GlucoWatch were excluded. Risk of bias was appraised with Cochrane risk of bias tool. Meta-analysis and meta-regression were performed using Review Manager software and R software, respectively. Heterogeneity was evaluated using χ 2 and I 2 statistics. Overall effects and certainty of evidence were evaluated using Z statistic and GRADE (Grading of Recommendations, Assessment, Development and Evaluation) software.Results Twenty-two studies, involving 2188 individuals with type 1 diabetes, were identified. Most studies had low risk of bias. Meta-analysis of 21 studies involving 2149 individuals revealed that CGM significantly decreased HbA 1c levels compared with SMBG (mean difference -2.46 mmol/mol [-0.23%] [95% CI -3.83, -1.08], Z = 3.50, p=0.0005), with larger effects experienced among higher baseline HbA 1c >64 mmol/mol (>8%) individuals (mean difference -4.67 mmol/mol [-0.43%] [95% CI -6.04, -3.30], Z = 6.69, p<0.00001). However, CGM had no influence on the number of severe hypoglycaemia (p=0.13) and DKA events (p=0.88). Certainty of evidence was moderate.Conclusions/interpretation CGM is superior to SMBG in improving glycaemic control among individuals with type 1 diabetes in the community, especially in those with uncontrolled glycaemia. Individuals with type 1 diabetes with HbA 1c >64 mmol/mol (>8%) are most likely to benefit from CGM. Current findings could not confer a concrete conclusion on the effectiveness of CGM on DKA outcome as DKA incidences were rare. Current evidence is also limited to outpatient settings. Future research should evaluate the accuracy of CGM and the effectiveness of CGM across different age groups and insulin regimens as these remain unclear in this paper.Prospero registration Registration no. CRD42020207042.Funding This research received no specific grant from any funding agency in the public, commercial or not-for-profit sectors.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
CGM has been extensively utilized in patients with Type 1 Diabetes, and emerging evidence supports its potential benefits in managing T2D.
“While CGM has been extensively utilized in patients with Type 1 Diabetes [7–9], emerging evidence supports its potential benefits in managing T2D.”
Two reviews [23, 34] evaluated the effect of CGM versus SMBG on DKA risk, with no statistically significant differences observed between intervention and control groups.
“Two reviews [23, 34] evaluated the effect of CGM versus SMBG on DKA risk, with no statistically significant differences observed between intervention and control groups.”
From Effectiveness of Wearable Devices for Diabetes Management: An Overview of Systematic Reviews and Meta‐Analyses (2026) · cites this paper as [23]
No significant differences have been observed between intervention and control groups for DKA prevention.
“Regarding DKA prevention, no significant differences have been observed between intervention and control groups [23, 34]”
From Effectiveness of Wearable Devices for Diabetes Management: An Overview of Systematic Reviews and Meta‐Analyses (2026) · cites this paper as [23]
The primary outcome was met and showed benefit in adults of all ages, including seniors.
“The primary outcome was met and showed benefit in adults of all ages (38,53,54), including seniors (55-57).”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [54]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 69 · Cited by 186
Research works printed but not linked: 2
- [4]4. Secrest AM, Washington RE, Orchard TJ. Mortality in Type 1 Diabetes. In: Cowie CC, Casagrande SS, Menke A, et al, editors. Diabetes in America. 3rd edition. Bethesda (MD): National Institute of Diabetes and Digestive and Kidney Diseases (US); 2018 Aug. CHAPTER 35. Available from: https://www.ncbi.nlm.nih.gov/books/ NBK567986/
- [34]34. Review Manager (RevMan) [Computer program]. Version 5.4.1. The Cochrane Collaboration, 2020
- Authors
- Teo, E., Hassan, N., Tam, W., & Koh, S.
- Affiliations
- National University of Singapore (SG)
- Changi General Hospital (SG)
- Corresponding author
- Teo, Evelyn
- Koh, Serena
- Venue
- Diabetologia
- Published
- 2022-02-09
- Volume
- 65
- Issue
- 4
- Pages
- 604-619
- ISSN
- 0012-186X (ISSN-L)
- 1432-0428
- OpenAlex
- W4211220471
- Cited by
- 186
- References
- 69
- Citations by year
- 2026: 39 · 2025: 54 · 2024: 47 · 2023: 33 · 2022: 13
- FWCI
- 5.22
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Diabetologia (publishedVersion)
- PubMed (publishedVersion)
- National University of Singapore (submittedVersion)
- Funders
- National University Health System
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- continuous glucose monitoring, type 1 diabetes, glycemic control, HbA1c, self-monitoring of blood glucose, severe hypoglycemia, diabetic ketoacidosis, multiple daily insulin injections, insulin pump therapy, risk of bias
- MeSH terms
- Glycemic Control, Blood Glucose, Diabetes Mellitus, Type 1, Female, Glycated Hemoglobin, Humans, Hypoglycemia, Insulin, Male, Blood Glucose Self-Monitoring, Diabetic Ketoacidosis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review