Air Sampling During Asbestos Abatement of Floor Tile and Mastic
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, the literature on the subject proves that even a small scope of work can cause a high concentration of asbestos aerosol.28–30,34,35”
From Comparison of the effects of use, protection, improper renovation and removal of asbestos products on the example of typical old office buildings in Poland (2023) · cites this paper as [29]
In the citing paper
“Asbestos vinyl tiles are often reported to have asbestos content of less than 10% (Kominsky et al. 1998a; Lange et al. 2000; HSE 2012), although there exist reports stating that the asbestos content may be as high as 30% (Anderson et al. 1982).”
From Measurements of airborne asbestos fibres during refurbishing (2023) · cites this paper as Lange et al. 2000
In the citing paper
“The airborne PCM fibre concentrations for personal samples varied in the reported studies from 0.001 f/cm3 to 1.7 f/cm3 depending on the work that was performed (Lundgren et al. 1991; Kominsky et al. 1998b; Lange et al. 2000, 2008; Lange 2001, 2002, 2004; Racine 2010).”
From Measurements of airborne asbestos fibres during refurbishing (2023) · cites this paper as Lange et al. 2000
Citations
Cites
Statistical Methods for Environmental Pollution Monitoring.
Lambert, D., & Gilbert, R. O. (1988) · Journal of the American Statistical Association · doi:10.2307/2290180 · Cited by 2,066
The physiological consequences of wearing industrial respirators: A review
Raven, P. B., DODSON, A. T., & DAVIS, T. O. (1979) · American Industrial Hygiene Association Journal · doi:10.1080/15298667991429912 · Cited by 56 · cited 1×
“Use of respirators below a “hazardous” exposure level has been suggested to result in increased physiological stress to the wearer ( Raven et al. 1979 ).”
BackgroundLange, J., Lange, P. R., Reinhard, T. K., & Thomulka, K. W. (1996) · The Annals of Occupational Hygiene · doi:10.1016/0003-4878(95)00081-x · Cited by 55 · cited 12×
“Sample rate for both types of measurements was (nominal) 2 Ipm as previously described ( Lange et al. 1996 ).”
BackgroundMethodResultSelf-citationA Statistical Evaluation of Asbestos Air Concentrations
Lange, J. H. (1999) · Indoor and Built Environment · doi:10.1177/1420326x9900800504 · Cited by 33
Self-citationThe Accuracy of Dust Exposure Estimates Obtained from Conventional Air Sampling
Breslin, A. J., Ong, L. S. D., Glauberman, H., George, A. C., & LeClare, P. C. (1967) · American Industrial Hygiene Association Journal · doi:10.1080/00028896709342486 · Cited by 30
Lange, J. H., & Thomulka, K. W. (2000) · International Journal of Environmental Health Research · doi:10.1080/09603120072956 · Cited by 26 · cited 2×
“Regulations requiring employment of “full” engineering controls and respiratory protection, based on these and other exposure data for floor tile and mastic ( Lange and Thomulka, 1999 ), could be categorized as legislating science.”
BackgroundSelf-citationOn the Interpretation of Air Sampling for Radioactive Particles
Sherwood, R. J. (1966) · American Industrial Hygiene Association Journal · doi:10.1080/00028896609342800 · Cited by 24
Stevens, D. C. (1969) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/12.1.33 · Cited by 22
Cited by
Westerlund, J., Graff, P., Bryngelsson, I.-L., Westberg, H., Eriksson, K., & Löfstedt, H. (2015) · Annals of Occupational Hygiene · doi:10.1093/annhyg/mev045 · Cited by 26
Occupational exposure to airborne asbestos from coatings, mastics, and adhesives
Paustenbach, D. J., Sage, A., Bono, M., & Mowat, F. S. (2004) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/sj.jea.7500320 · Cited by 24
“Similar results were presented by the same authors when calculating TWAs after shot-blasting removal of mastic from underneath floor tiles (Lange and Thomulka, 2000b).”
BackgroundMethodResultInfluentialLange, J. H., Sites, S. L. M., Mastrangelo, G., & Thomulka, K. W. (2007) · Bulletin of Environmental Contamination and Toxicology · doi:10.1007/s00128-007-9280-x · Cited by 16
Self-citationMeasurements of airborne asbestos fibres during refurbishing
Ervik, T. K., Hammer, S. E., Skaugset, N. P., & Graff, P. (2023) · Annals of Work Exposures and Health · doi:10.1093/annweh/wxad041 · Cited by 14
Lange, J. H. (2001) · Indoor and Built Environment · doi:10.1159/000049236 · Cited by 12
Self-citationPerez, A. L., Nelson, M. L., Cheng, T. J., Comerford, C. E., & Scott, P. K. (2018) · International Journal of Occupational and Environmental Health · doi:10.1080/10773525.2018.1533671 · Cited by 12
“9 Lange and Thomulka [11] Peer-reviewed PCM (25) Personal, area 10 Lange and Thomulka [40] Peer-reviewed PCM (23) TWA samples only 11 Lange [19] Peer-reviewed PCM (11)* Personal 12 Lange [14] Peer-reviewed PCM (30)* Personal 13 Lange [39] Peer-reviewed PCM (4)** Personal 14 Lange et al.”
BackgroundArea and Personal Airborne Exposure During Abatement of Asbestos-Containing Roofing Material
Lange, J. H., & Thomulka, K. W. (2000) · Bulletin of Environmental Contamination and Toxicology · doi:10.1007/s001280000056 · Cited by 10
“As suggested in other occupational studies (Lange, 1999; Lange and Thomulka, 1999, 1999a ) personal air samples appear to best represent exposure to workers.”
BackgroundSelf-citationObmiński, A. (2024) · Scientific Reports · doi:10.1038/s41598-024-70631-z · Cited by 9
“The values obtained from "area samples" are much lower than taken from the worker’s breathing zone, named “personal samples” 16,30,36,37 The author obtained the results during asbestos removal tests: “area samples” inside buildings on the level approx.”
BackgroundDufresne, A., Dion, C., Viau, S., Cloutier, Y., & Perrault, G. (2009) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620903249828 · Cited by 8
Lange, J. H. (2005) · Indoor and Built Environment · doi:10.1177/1420326x05050675 · Cited by 6
Self-citationLange, J. H., Bules, M., Lindquist, J., Gray, M., & Ivarone, C. (2000) · Indoor and Built Environment · doi:10.1177/1420326x0000900606 · Cited by 5
Self-citationHas the World Trade Center Tragedy Established a New Standard for Asbestos?
Lange, J. H. (2001) · Indoor and Built Environment · doi:10.1177/1420326x0101000602 · Cited by 8
Self-citationObmiński, A. (2023) · Scientific Reports · doi:10.1038/s41598-023-37257-z · Cited by 4
Are personal and static samples related?: Table 1
Lange, J. H. (2003) · Occupational and Environmental Medicine · doi:10.1136/oem.60.3.224 · Cited by 4
Self-citationEmergence of a New Policy for Asbestos: A Result of the World Trade Center Tragedy
Lange, J. H. (2004) · Indoor and Built Environment · doi:10.1177/1420326x04038959 · Cited by 7
Self-citationLegacy asbestos: An ongoing public health risk
Pfau, J. C., & McNew, T. (2026) · Open Access Government · doi:10.56367/oag-049-11796 · Cited by 1
Improving Air Quality: Progress and Challenges for the Auto Industry
Williams, M. L. (2003) · Occupational and Environmental Medicine · doi:10.1136/oem.60.3.226 · Cited by 1
Serpentine and Amphibole Asbestos [A Subset of Elongated Mineral Particles (EMPs)]
Havics, A. A., & Bernstein, D. M. (2024) · Wiley eBooks · doi:10.1002/0471125474.tox012.pub3
Wpływ zewnętrznych źródeł emisji azbestu na powietrze wewnętrzne eksploatowanych budynków
Obmiński, A. (2026) · Ciepłownictwo, Ogrzewnictwo, Wentylacja · doi:10.65545/cow.2026.07-08.04
Metadata
- Authors
- Lange, J. H., & Thomulka, K. W.
- Affiliations
- University of the Sciences (US)
- Venue
- Bulletin of Environmental Contamination and Toxicology
- Published
- 2000-04-01
- Volume
- 64
- Issue
- 4
- Pages
- 497-501
- ISSN
- 0007-4861 (ISSN-L)
- 1432-0800
- OpenAlex
- W2014698107
- Cited by
- 18
- References
- 8
- Citations by year
- 2026: 1 · 2024: 2 · 2023: 2 · 2018: 1 · 2015: 1
- FWCI
- 1.84
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Bulletin of Environmental Contamination and Toxicology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Occupational and environmental lung diseases
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Safety in Workplaces
- Keywords
- asbestos removal, air sampling, floor tiles, mastic, airborne asbestos fibers, occupational exposure, indoor air quality
- MeSH terms
- Asbestos, Humans, Manufactured Materials, Occupational Exposure, Air Pollution, Indoor, Inhalation Exposure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.