Comparison of the effects of use, protection, improper renovation and removal of asbestos products on the example of typical old office buildings in Poland
Open accessPublished version of a preprint
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index; 7 of the 27 sources its claims cite were checked for support.
Abstract
The study focused on old, German building types “LIPSK” and “BERLIN” used in Poland, since the 1960s in Eastern Europe. The different operations on buildings were analysed: protection and maintenance of asbestos products, asbestos removal and inadvertent damage to asbestos as a result of building renovation. Measurements of respirable (countable) asbestos fibres in the air were carried out using the PCOM + PLM method and SEM–EDS. In the case of the accidental destruction of products, initial contamination was ≈7000 f/m 3 . After 16 weeks from the end of the activity and 20 days of extreme ventilation, contamination decreased to about 500 f/m 3 . At the same time, in similar rooms, without extreme ventilation, the pollution was above 4000 f/m 3 . The average increase in pollution in a dozen or so similar buildings, after asbestos removal in places beyond the work zones, ranged from ≈ 1700–2700 f/m 3 and lasted for one or two years. These buildings, used without ACM destruction or after product impregnation, have maintained low asbestos contamination < 300 f/m 3 for more than 10–20 years. So, due to the easy release of asbestos that occurs with any ACM removal and the increased risk of occupant exposure, these works are often inappropriate for the buildings in question.
Overview
CoChat Summary
## TL;DR
This paper compares airborne asbestos in old Polish office buildings under normal use, protection/encapsulation, improper renovation, asbestos removal, and demolition. It argues that leaving ACMs in place or properly protecting them can keep contamination low for years, while removal or accidental damage can produce much higher and longer-lasting airborne fiber levels.
## Key findings
- In accidental destruction of asbestos-containing products, initial contamination was about 7000 f/m3; after 16 weeks and 20 days of extreme ventilation, it fell to about 500 f/m3, but in similar rooms without extreme ventilation it remained above 4000 f/m3.
- After asbestos removal in buildings beyond the work zones, the average increase in pollution in a dozen or so similar buildings ranged from about 1700–2700 f/m3 and lasted one or two years.
- Buildings used without ACM destruction or after product impregnation maintained low asbestos contamination of < 300 f/m3 for more than 10–20 years.
- In the author’s measurements, normal use and small local damage in occupied buildings generally stayed around < 300 f/m3, with a reported maximum of 560 f/m3; more extensive disturbance/removal was associated with 2000–6000 f/m3 or more in affected zones.
## Methods
- Comparative field study of typical old German building types in Poland, especially “BERLIN” and “LIPSK”, plus a demolition case (“MOA”), observed across different stages: normal use, preservation/protection, renovation damage, asbestos removal, and demolition.
- Air sampling of respirable asbestos fibers using static and dynamic sampling; filters were analyzed by PCM + PLM and some tests by SEM–EDS, following ISO-based procedures.
- The study examined buildings and air samples in Poland over 2002–2022; analysis focused on fiber concentrations in rooms and in areas distant from work zones, with comparisons over time.
## Limitations
- The paper states that outdoor air, large-volume rooms, badly damaged buildings, and short-interval repeat tests show large dispersion; results should be treated as approximate.
- It also states that only chrysotile was identified in material samples and air samples, so the findings may not generalize to other asbestos types.
- Evident from the text: the study is based on selected buildings and area measurements with time lag from the works, so it cannot provide a universally fixed asbestos concentration for all buildings or a direct causal estimate of health risk.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures



![Figure 4 (a) Trend of changes in Building no. 1 over time. The X-axis is the elapsed time [in weeks], and the Y-axis is the concentration of respirable asbestos fibres [f/m3]. (b) Trend of changes in Building no. 2 over time. The X-axis is the elapsed time [in weeks], and the Y-axis is the concentration of respirable asbestos fibres [f/m3].](https://figures.cochat.ai/paper-figures/63fb0b26a8c147f39ecadde8510b00a1/comparison-of-the-effects-of-use-protection-improper-renovation-and-removal-of-figure-4.jpg)


Verification
Claims the paper makes
3 Valid · 5 Not valid · 6 Not checked · 29 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The measured concentration of fibres varies depending on the activity of new dust emission sources, the time that has passed between their formation and sampling, and the building’s use, ventilation and general condition34,35,38.”
§ Comparison of the effects of use, protection, improper renovation and removal of asbestos products on the example of typical old office buildings in Poland > Introduction > Literature review and relation to the data
What the sources say
- Not matchedcites [34] ECHA Scientific report for evaluation of limit values for asbestos at the workplace. Prepared by the European Chemicals Agency 1 February 2021 for the EU Occupational Safety and Health Legislation. https://echa.europa.eu/documents/10162/2c23f940-fff8-59ab-43b1-05aadb30042e
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Not matchedcites [35] Obmiński, A. Asbestos in buildings, Scientific Studies, Building Research, Institute, Warsaw 2017 (in Polish)
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
- Supportedcites [38] Obmiński, A. The natural reduction of threat in selected systems of old buildings containing asbestos. Sci. Rep. 12, 2580. https://doi.org/10.1038/s41598-021-04487-y (2022). source
The Introduction’s literature review says asbestos dust concentrations depend on the time between aerosol formation and sampling, and describes activities that disturb asbestos products. It also identifies building condition, use and ventilation as factors affecting measured concentrations. The Discussion of results likewise describes sources that increase dust and ventilation that reduces it. (LLM, conf=0.91)
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not matched
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Only chrysotile fibres were detected in the air samples.”
- Also stated in: § Purpose of the study · plain
“Only chrysotile, the dominant asbestos in ACM products, was recorded in the air samples too.”
§ Comparison of the effects of use, protection, improper renovation and removal of asbestos products on the example of typical old office buildings in Poland > Results
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Also stated in: § Purpose of the study · plain
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The levels of contamination after accidental ACM damage and careless or erroneous asbestos removal during renovation works were found far beyond the work zones, and also during the use of the buildings. These are values of about several thousand f/m3 with a range ≈ of 2000–6000 f/m3.”
§ Comparison of the effects of use, protection, improper renovation and removal of asbestos products on the example of typical old office buildings in Poland > Data analyses and discussion
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“After 16 weeks from the end of the activity and 20 days of extreme ventilation, contamination decreased to about 500 f/m3.”
§ Comparison of the effects of use, protection, improper renovation and removal of asbestos products on the example of typical old office buildings in Poland > Abstract
plainstates a causeSingle case- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“The average increase in pollution in a dozen or so similar buildings, after asbestos removal in places beyond the work zones, ranged from ≈ 1700–2700 f/m3 and lasted for one or two years.”
§ Comparison of the effects of use, protection, improper renovation and removal of asbestos products on the example of typical old office buildings in Poland > Abstract
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
22 more claims
Create a free account to see all 43 claims and every source verdict.
- Probably not a substantial claim. 10
- It may state two separate claims as one. 9
Citations
Cites
Indoor air quality differences between urban and rural preschools in Korea
Yoon, C., Lee, K., & Park, D. (2010) · Environmental Science and Pollution Research · doi:10.1007/s11356-010-0377-0 · Cited by 146
Grmasha, R. A., Abdulameer, M. H., Stenger‐Kovács, C., et al. (2023) · Marine Pollution Bulletin · doi:10.1016/j.marpolbul.2022.114568 · Cited by 107
Grmasha, R. A., Al-sareji, O. J., Salman, J. M., & Hashim, K. (2020) · Journal of King Saud University - Engineering Sciences · doi:10.1016/j.jksues.2020.11.002 · Cited by 106
Pleural Mesothelioma in New Caledonia: Associations with Environmental Risk Factors
Baumann, F., Maurizot, P., Mangeas, M., Ambrosi, J.-P., Douwes, J., & Robineau, B. (2011) · Environmental Health Perspectives · doi:10.1289/ehp.1002862 · Cited by 89
Airborne asbestos in buildings
Lee, R. J., & Van Orden, D. R. (2008) · Regulatory Toxicology and Pharmacology · doi:10.1016/j.yrtph.2007.10.005 · Cited by 70
Asbestos Exposure During Renovation and Demolition of Asbestos-Cement Clad Buildings
BROWN, S. K. (1987) · American Industrial Hygiene Association Journal · doi:10.1080/15298668791385075 · Cited by 49 · cited 2×
“The results of "faulty works" carried out using "dry" or “DIY” techniques were reported by Brown 30 and others 36,37 .”
BackgroundAsbestos Exposure among Construction Workers During Demolition of Old Houses in Tehran, Iran
KAKOOEI, H., & NORMOHAMMADI, M. (2014) · Industrial Health · doi:10.2486/indhealth.2012-0118 · Cited by 39
Al-sareji, O. J., Grmasha, R. A., Hashim, K., et al. (2022) · Building and Environment · doi:10.1016/j.buildenv.2022.108847 · Cited by 38
Asbestos in building and its destruction
Obmiński, A. (2020) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2020.118685 · Cited by 28
Self-citationEnvironmental asbestos pollution — Situation in Poland
Szeszenia-Dąbrowska, N., Sobala, W., Świątkowska, B., Stroszejn-Mrowca, G., & Wilczyńska, U. (2012) · International Journal of Occupational Medicine and Environmental Health · doi:10.2478/s13382-012-0003-0 · Cited by 27
Research works printed but not linked: 2
- Al-Sareji, O. J., Grmasha, R. A., Salman, J. M. & Hashim, K. S. Street dust contamination by heavy metals in Babylon governorate, Iraq. J. Eng. Sci. Technol. 16(1), 455–469 (2021).
- Upton, A. C. Asbestos in Public and Commercial Buildings - A literature revive and synthesis of current knowledge, Health Effect Institute - Asbestos Research. Cambridge (1991) https://www.healtheffects.org/publication/asbestos-public-and-commercial-buildings.
Cited by
Obmiński, A. (2024) · Scientific Reports · doi:10.1038/s41598-024-70631-z · Cited by 9
Self-citationChoudhury, A. R., Singh, N. C., Chinthala, S., et al. (2025) · Environmental Science Atmospheres · doi:10.1039/d5ea00027k · Cited by 6
Pathways to asbestos-free and sustainable cities using multi-level perspective approach
Macher, G. Z., & Szigeti, C. (2025) · Discover Sustainability · doi:10.1007/s43621-025-01932-0 · Cited by 8
“Additionally, public-private partnerships (abbreviation: PPPs) may encourage cooperation between government entities and private companies to fund large-scale asbestos removal projects [36].”
Bharka, E., & Ariyanti, F. D. (2025) · IOP Conference Series Earth and Environmental Science · doi:10.1088/1755-1315/1564/1/012122
“[5] Obmiński, 2023).”
Metadata
- Authors
- Obmiński, A.
- Affiliations
- Instytut Techniki Budowlanej (PL)
- Corresponding author
- Obmiński, Andrzej
- ORCID
- Obmiński, Andrzej
- Venue
- Scientific Reports
- Published
- 2023-08-21
- Volume
- 13
- Issue
- 1
- Pages
- 13577-13577
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC10442424
- OpenAlex
- W4386027889
- Cited by
- 4
- References
- 35
- Citations by year
- 2025: 3 · 2024: 1
- FWCI
- 0.73
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Scientific Reports (publishedVersion, cc-by)
- Research Square (acceptedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Occupational and environmental lung diseases
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Safety in Workplaces
- Keywords
- asbestos-containing materials, asbestos removal, building renovation, office buildings, occupant exposure, ventilation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-01, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-01 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of the effects of use, protection, improper renovation and removal of asbestos products on the example of typical old office buildings in Poland. https://app.cochat.ai/papers/10.1038/s41598-023-37257-z
- The paper
- Obmiński, A. (2023). Comparison of the effects of use, protection, improper renovation and removal of asbestos products on the example of typical old office buildings in Poland. Scientific Reports. https://doi.org/10.1038/s41598-023-37257-z
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.