Variability of cortisol assays can confound the diagnosis of adrenal insufficiency in the critically ill population
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Objective To compare the total plasma cortisol values obtained from three widely used immunoassays and a high pressure liquid chromatography (HPLC) technique on samples obtained from patients with sepsis.Design and setting Observational interventional in the general intensive care unit of a metropolitan hospital Patients and participants Patients admitted to the intensive care unit with a diagnosis of sepsis and fulfilling criteria of systemic inflammatory response syndrome.Interventions Standard short synacthen test performed with 250microg cosyntropin.Measurements and results Two of the three immunoassays returned results significantly higher than those obtained by HPLC: Immulite by 95% (95%CI 31-188%) and TDx by 79% (21-165%). The limits of agreement for all three immunoassays with HPLC ranged from -62% to 770%. In addition, by classifying the patients into responders and non-responders to ACTH by standard criteria there was concordance in all assays in only 44% of patients.Conclusions Immunoassay estimation of total plasma cortisol in septic patients shows wide assay related variation that may have significant impact in the diagnosis of relative adrenal insufficiency.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Traditional immunoassays are associated with considerable interassay variation and potential cross-reactivity with other steroids, which may lead to over- and underestimations of true levels in critically ill patients with stress-induced stimulation of the hypothalamic-pituitary-adrenal axis (23, 24).”
From Prevention of adrenal crisis: cortisol responses to major stress compared to stress dose hydrocortisone delivery (2020) · cites this paper as [24]
Citations
Cites
2001 SCCM/ESICM/ACCP/ATS/SIS International Sepsis Definitions Conference
Levy, M. M., Fink, M. P., Marshall, J. C., Abraham, E., Angus, D., Cook, D., Cohen, J., Opal, S. M., Vincent, J.-L., & Ramsay, G. (2003) · Critical Care Medicine · doi:10.1097/01.ccm.0000050454.01978.3b · Cited by 5,995
Annane, D. (2002) · JAMA · doi:10.1001/jama.288.7.862 · Cited by 3,087
Corticosteroid insufficiency in acutely ill patients
Cooper, M. S., & Stewart, P. M. (2003) · New England Journal of Medicine · doi:10.1056/nejmra020529 · Cited by 1,033
Annane, D. (2000) · JAMA · doi:10.1001/jama.283.8.1038 · Cited by 1,000 · cited 1×
“Plasma cortisol is measured in most institutions by immunoassay, and the majority of recent studies in this field have utilised this technique [1, 2, 3, 4].”
MethodLASHANSKY, G., SAENGER, P., FISHMAN, K., GAUTIER, T., MAYES, D., BERG, G., MARTINO-NARDI, J. D., & REITER, E. (1991) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-73-3-674 · Cited by 222
Clark, Neylon, Raggatt, Sheppard, & Stewart (1998) · Clinical Endocrinology · doi:10.1046/j.1365-2265.1998.00555.x · Cited by 207 · cited 2×
“244 between five different immunoassays [5].”
Adrenocortical function during septic shock
Bouachour, G., Tirot, P., Gouello, J. P., Mathieu, E., Vincent, J. F., & Alquier, P. (1995) · Intensive Care Medicine · doi:10.1007/bf02425155 · Cited by 164
Cortisol levels and mortality in severe sepsis
Sam, S., Corbridge, T. C., Mokhlesi, B., Comellas, A. P., & Molitch, M. E. (2004) · Clinical Endocrinology · doi:10.1111/j.1365-2265.2004.01923.x · Cited by 161
Siraux, V., De Backer, D., Yalavatti, G., Mélot, C., Gervy, C., Mockel, J., & Vincent, J.-L. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000185641.87051.7c · Cited by 123
Cortisol Assays: Guidelines for the Provision of a Clinical Biochemistry Service
Moore, A., Aitken, R. G., Burke, C., Gaskell, S. J., Groom, G. V., Holder, G., Selby, C., & Wood, P. (1985) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/000456328502200501 · Cited by 93
Cited by
Hydrocortisone Therapy for Patients with Septic Shock
Sprung, C. L., Annane, D., Keh, D., Moreno, R., Singer, M., Freivogel, K., Weiss, Y. G., Benbenishty, J., Kalenka, A., Forst, H., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa071366 · Cited by 2,132
Marik, P. E., Pastores, S. M., Annane, D., Meduri, G. U., Sprung, C. L., Arlt, W., Keh, D., Briegel, J., Beishuizen, A., Dimopoulou, I., et al. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e31817603ba · Cited by 912
“It is likely that the variation in assay characteristics might be even more significant in critically ill patients, especially those with septic shock (91, 92).”
BackgroundMeasuring cortisol in serum, urine and saliva—Are our assays good enough?
El-Farhan, N., Rees, D. A., & Evans, C. (2017) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/0004563216687335 · Cited by 395
Critical Illness-Related Corticosteroid Insufficiency
Marik, P. E. (2009) · Chest · doi:10.1378/chest.08-1149 · Cited by 299
Cerebral perfusion in sepsis-associated delirium
Pfister, D., Siegemund, M., Dell-Kuster, S., Smielewski, P., Rüegg, S., Strebel, S. P., Marsch, S. C., Pargger, H., & Steiner, L. A. (2008) · Critical Care · doi:10.1186/cc6891 · Cited by 258
Metadata
- Authors
- Cohen, J., Ward, G., Prins, J., Jones, M., & Venkatesh, B.
- Affiliations
- Ipswich Hospital (AU)
- Princess Alexandra Hospital (AU)
- The University of Queensland (AU)
- Corresponding author
- Cohen, Jeremy
- Venue
- Intensive Care Medicine
- Published
- 2006-09-22
- Volume
- 32
- Issue
- 11
- Pages
- 1901-1905
- ISSN
- 0342-4642 (ISSN-L)
- 1432-1238
- OpenAlex
- W2069398513
- Cited by
- 83
- References
- 17
- Citations by year
- 2025: 2 · 2024: 1 · 2022: 3 · 2021: 2 · 2020: 2 · 2019: 2 · 2018: 3 · 2017: 4 · 2016: 3 · 2015: 4 · 2014: 7 · 2012: 6
- FWCI
- 6.87
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Intensive Care Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Adrenal Hormones and Disorders
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Sepsis Diagnosis and Treatment
- Keywords
- adrenal insufficiency, sepsis, immunoassay comparison, HPLC, ACTH stimulation test, ACTH response, systemic inflammatory response syndrome, critically ill patients, diagnostic agreement
- MeSH terms
- Adrenal Cortex Function Tests, Adrenal Insufficiency, Adult, Analysis of Variance, Chromatography, High Pressure Liquid, Diagnostic Errors, Humans, Hydrocortisone, Immunoassay, Reagent Kits, Diagnostic, Reproducibility of Results, Sepsis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Variability of cortisol assays can confound the diagnosis of adrenal insufficiency in the critically ill population. https://app.cochat.ai/papers/10.1007/s00134-006-0389-x
- The paper
- Cohen, J., Ward, G., Prins, J., Jones, M., & Venkatesh, B. (2006). Variability of cortisol assays can confound the diagnosis of adrenal insufficiency in the critically ill population. Intensive Care Medicine. https://doi.org/10.1007/s00134-006-0389-x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.