CoChat

Variability of cortisol assays can confound the diagnosis of adrenal insufficiency in the critically ill population

Cohen, Jeremy, Ward, Gregory, Prins, Johannes, Jones, Mark, Venkatesh, Bala · 2006 · Intensive Care Medicine

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Abstract

Objective To compare the total plasma cortisol values obtained from three widely used immunoassays and a high pressure liquid chromatography (HPLC) technique on samples obtained from patients with sepsis.Design and setting Observational interventional in the general intensive care unit of a metropolitan hospital Patients and participants Patients admitted to the intensive care unit with a diagnosis of sepsis and fulfilling criteria of systemic inflammatory response syndrome.Interventions Standard short synacthen test performed with 250microg cosyntropin.Measurements and results Two of the three immunoassays returned results significantly higher than those obtained by HPLC: Immulite by 95% (95%CI 31-188%) and TDx by 79% (21-165%). The limits of agreement for all three immunoassays with HPLC ranged from -62% to 770%. In addition, by classifying the patients into responders and non-responders to ACTH by standard criteria there was concordance in all assays in only 44% of patients.Conclusions Immunoassay estimation of total plasma cortisol in septic patients shows wide assay related variation that may have significant impact in the diagnosis of relative adrenal insufficiency.

Overview

Integrity signals

Registry

Crossref · 10.1007/s00134-006-0389-x

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 17 references

Cited by

See all 83

Metadata

Authors
Cohen, J., Ward, G., Prins, J., Jones, M., & Venkatesh, B.
Affiliations
  • Ipswich Hospital (AU)
  • Princess Alexandra Hospital (AU)
  • The University of Queensland (AU)
Corresponding author
Cohen, Jeremy
Venue
Intensive Care Medicine
Published
2006-09-22
Volume
32
Issue
11
Pages
1901-1905
ISSN
  • 0342-4642 (ISSN-L)
  • 1432-1238
OpenAlex
W2069398513
Cited by
83
References
17
Citations by year
2025: 2 · 2024: 1 · 2022: 3 · 2021: 2 · 2020: 2 · 2019: 2 · 2018: 3 · 2017: 4 · 2016: 3 · 2015: 4 · 2014: 7 · 2012: 6
FWCI
6.87
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • Intensive Care Medicine (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Adrenal Hormones and Disorders
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Sepsis Diagnosis and Treatment
Keywords
adrenal insufficiency, sepsis, immunoassay comparison, HPLC, ACTH stimulation test, ACTH response, systemic inflammatory response syndrome, critically ill patients, diagnostic agreement
MeSH terms
Adrenal Cortex Function Tests, Adrenal Insufficiency, Adult, Analysis of Variance, Chromatography, High Pressure Liquid, Diagnostic Errors, Humans, Hydrocortisone, Immunoassay, Reagent Kits, Diagnostic, Reproducibility of Results, Sepsis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Variability of cortisol assays can confound the diagnosis of adrenal insufficiency in the critically ill population. https://app.cochat.ai/papers/10.1007/s00134-006-0389-x
The paper
Cohen, J., Ward, G., Prins, J., Jones, M., & Venkatesh, B. (2006). Variability of cortisol assays can confound the diagnosis of adrenal insufficiency in the critically ill population. Intensive Care Medicine. https://doi.org/10.1007/s00134-006-0389-x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.