Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 262

The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.

Quantitative versus standard pupillary light reflex for early prognostication in comatose cardiac arrest patients: an international prospective multicenter double-blinded study

Open access
Oddo, Mauro, Sandroni, Claudio, Citerio, Giuseppe, Miroz, John-Paul, Horn, Janneke, Rundgren, Malin, Cariou, Alain, Payen, Jean-François, Storm, Christian, Stammet, Pascal, Taccone, Fabio Silvio · 2018 · Intensive Care Medicine

Abstract

PURPOSE: To assess the ability of quantitative pupillometry [using the Neurological Pupil index (NPi)] to predict an unfavorable neurological outcome after cardiac arrest (CA). METHODS: We performed a prospective international multicenter study (10 centers) in adult comatose CA patients. Quantitative NPi and standard manual pupillary light reflex (sPLR)-blinded to clinicians and outcome assessors-were recorded in parallel from day 1 to 3 after CA. Primary study endpoint was to compare the value of NPi versus sPLR to predict 3-month Cerebral Performance Category (CPC), dichotomized as favorable (CPC 1-2: full recovery or moderate disability) versus unfavorable outcome (CPC 3-5: severe disability, vegetative state, or death). RESULTS: At any time between day 1 and 3, an NPi ≤ 2 (n = 456 patients) had a 51% (95% CI 49-53) negative predictive value and a 100% positive predictive value [PPV; 0% (0-2) false-positive rate], with a 100% (98-100) specificity and 32% (27-38) sensitivity for the prediction of unfavorable outcome. Compared with NPi, sPLR had significantly lower PPV and significantly lower specificity (p < 0.001 at day 1 and 2; p = 0.06 at day 3). The combination of NPi ≤ 2 with bilaterally absent somatosensory evoked potentials (SSEP; n = 188 patients) provided higher sensitivity [58% (49-67) vs. 48% (39-57) for SSEP alone], with comparable specificity [100% (94-100)]. CONCLUSIONS: Quantitative NPi had excellent ability to predict an unfavorable outcome from day 1 after CA, with no false positives, and significantly higher specificity than standard manual pupillary examination. The addition of NPi to SSEP increased sensitivity of outcome prediction, while maintaining 100% specificity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00134-018-5448-6

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 26 references

Cited by

See all 262

Metadata

Authors
Oddo, M., Sandroni, C., Citerio, G., Miroz, J.-P., Horn, J., Rundgren, M., Cariou, A., Payen, J.-F., Storm, C., Stammet, P., & Taccone, F. S.
Venue
Intensive Care Medicine
Published
2018-11-26
Volume
44
Issue
12
Pages
2102-2111
ISSN
  • 0342-4642 (ISSN-L)
  • 1432-1238
OpenAlex
W2902907967
Cited by
262
References
26
FWCI
31.07
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantitative versus standard pupillary light reflex for early prognostication in comatose cardiac arrest patients: an international prospective multicenter double-blinded study. https://app.cochat.ai/papers/10.1007/s00134-018-5448-6
The paper
Oddo, M., Sandroni, C., Citerio, G., Miroz, J.-P., Horn, J., Rundgren, M., Cariou, A., Payen, J.-F., Storm, C., Stammet, P., & Taccone, F. S. (2018). Quantitative versus standard pupillary light reflex for early prognostication in comatose cardiac arrest patients: an international prospective multicenter double-blinded study. Intensive Care Medicine. https://doi.org/10.1007/s00134-018-5448-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.