Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 261

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Physiological and quantitative CT-scan characterization of COVID-19 and typical ARDS: a matched cohort study

Open access
Chiumello, Davide, Busana, Mattia, Coppola, Silvia, Romitti, Federica, Formenti, Paolo, Bonifazi, Matteo, Pozzi, Tommaso, Palumbo, Maria Michela, Cressoni, Massimo, Herrmann, Peter, Meissner, Konrad, Quintel, Michael, Camporota, Luigi, Marini, John J., Gattinoni, Luciano · 2020 · Intensive Care Medicine

Abstract

To investigate whether COVID-19-ARDS differs from all-cause ARDS. Thirty-two consecutive, mechanically ventilated COVID-19-ARDS patients were compared to two historical ARDS sub-populations 1:1 matched for PaO 2 /FiO 2 or for compliance of the respiratory system. Gas exchange, hemodynamics and respiratory mechanics were recorded at 5 and 15 cmH 2 O PEEP. CT scan variables were measured at 5 cmH 2 O PEEP. Anthropometric characteristics were similar in COVID-19-ARDS, PaO 2 /FiO 2 -matched-ARDS and Compliance-matched-ARDS. The PaO 2 /FiO 2 -matched-ARDS and COVID-19-ARDS populations (both with PaO 2 /FiO 2 106 ± 59 mmHg) had different respiratory system compliances (Crs) (39 ± 11 vs 49.9 ± 15.4 ml/cmH 2 O, p = 0.03). The Compliance-matched-ARDS and COVID-19-ARDS had similar Crs (50.1 ± 15.7 and 49.9 ± 15.4 ml/cmH 2 O, respectively) but significantly lower PaO 2 /FiO 2 for the same Crs (160 ± 62 vs 106.5 ± 59.6 mmHg, p < 0.001). The three populations had similar lung weights but COVID-19-ARDS had significantly higher lung gas volume (PaO 2 /FiO 2 -matched-ARDS 930 ± 644 ml, COVID-19-ARDS 1670 ± 791 ml and Compliance-matched-ARDS 1301 ± 627 ml, p < 0.05). The venous admixture was significantly related to the non-aerated tissue in PaO 2 /FiO 2 -matched-ARDS and Compliance-matched-ARDS ( p < 0.001) but unrelated in COVID-19-ARDS ( p = 0.75), suggesting that hypoxemia was not only due to the extent of non-aerated tissue. Increasing PEEP from 5 to 15 cmH 2 O improved oxygenation in all groups. However, while lung mechanics and dead space improved in PaO 2 /FiO 2 -matched-ARDS, suggesting recruitment as primary mechanism, they remained unmodified or worsened in COVID-19-ARDS and Compliance-matched-ARDS, suggesting lower recruitment potential and/or blood flow redistribution. COVID-19-ARDS is a subset of ARDS characterized overall by higher compliance and lung gas volume for a given PaO 2 /FiO 2 , at least when considered within the timeframe of our study.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00134-020-06281-2

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 30 references

Cited by

See all 261

Metadata

Authors
Chiumello, D., Busana, M., Coppola, S., Romitti, F., Formenti, P., Bonifazi, M., Pozzi, T., Palumbo, M. M., Cressoni, M., Herrmann, P., Meissner, K., Quintel, M., Camporota, L., Marini, J. J., & Gattinoni, L.
Venue
Intensive Care Medicine
Published
2020-10-21
Volume
46
Issue
12
Pages
2187-2196
ISSN
  • 0342-4642 (ISSN-L)
  • 1432-1238
OpenAlex
W3094251384
Cited by
261
References
30
FWCI
26.60
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Physiological and quantitative CT-scan characterization of COVID-19 and typical ARDS: a matched cohort study. https://app.cochat.ai/papers/10.1007/s00134-020-06281-2
The paper
Chiumello, D., Busana, M., Coppola, S., Romitti, F., Formenti, P., Bonifazi, M., Pozzi, T., Palumbo, M. M., Cressoni, M., Herrmann, P., Meissner, K., Quintel, M., Camporota, L., Marini, J. J., & Gattinoni, L. (2020). Physiological and quantitative CT-scan characterization of COVID-19 and typical ARDS: a matched cohort study. Intensive Care Medicine. https://doi.org/10.1007/s00134-020-06281-2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.