CoChat

Comparing in vivo kinematics of unicondylar and bi‐unicondylar knee replacements

Banks, Scott A., Fregly, Benjamin J., Boniforti, Filippo, Reinschmidt, Christoph, Romagnoli, Sergio · 2005 · Knee Surgery, Sports Traumatology, Arthroscopy
Cited by 174

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Preserving both cruciate ligaments in unicondylar knee arthroplasty likely provides more normal knee mechanics and contributes to enhanced patient function. It follows that preserving both cruciate ligaments with total knee arthroplasty should provide functional benefit compared to arthroplasty sacrificing one or both cruciates. The purpose of this study was to compare knee kinematics in patients with optimally functioning cruciate‐preserving medial unicondylar and bi‐unicondylar arthroplasty to determine if knee motions differed. Eight consenting patients with seven medial unicondylar and five bi‐unicondylar arthroplasties were studied using lateral fluoroscopy during treadmill gait, stair stepping, and maximum flexion activities. Patient‐specific geometric models based on CT and CAD data were used for shape matching to determine the three‐dimensional knee kinematics. Tibiofemoral contact locations were computed for the replaced compartments. Maximum flexion in kneeling was 135°±14° for unicondylar knees and 123°±14° for bi‐unicondylar knees (p=0.22). For 0°–30° flexion during the stair activity, the medial condyle translated posterior 3.5±2.5 mm in unicondylar knees and 4.7±1.9 mm in bi‐unicondylar knees (p>0.05). Lateral posterior translation was 5.0±2.3 mm in bi‐unicondylar knees for 0°–30° flexion. From heel‐strike to mid‐stance phase, there was little tibial rotation, but unicondylar knees showed 1.5±1.6 mm posterior translation of the medial condyle, while bi‐unicondylar knees showed 5.1±2.2 mm (p<<0.05). The bi‐unicondylar knees showed 3.8±3.4 mm posterior lateral condylar translation. Preserving both cruciate ligaments in knee arthroplasty appears to maintain some basic features of normal knee kinematics. Knees with bi‐unicondylar arthroplasty showed kinematics closer to motions observed in total knee arthroplasty, slightly less weight‐bearing flexion, and greater dynamic laxity in gait than unicondylar knees. Despite kinematic differences, knees with unicondylar and bi‐unicondylar arthroplasty can provide excellent functional outcomes in appropriately selected patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00167-004-0565-x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 174

Metadata

Authors
Banks, S. A., Fregly, B. J., Boniforti, F., Reinschmidt, C., & Romagnoli, S.
Venue
Knee Surgery, Sports Traumatology, Arthroscopy
Publisher
Wiley
Published
2005-01-20
Volume
13
Issue
7
Pages
551-556
ISSN
  • 0942-2056 (ISSN-L)
  • 1433-7347
OpenAlex
W2044014917
Cited by
174
References
1
FWCI
7.94
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparing in vivo kinematics of unicondylar and bi‐unicondylar knee replacements. https://app.cochat.ai/papers/10.1007/s00167-004-0565-x
The paper
Banks, S. A., Fregly, B. J., Boniforti, F., Reinschmidt, C., & Romagnoli, S. (2005). Comparing in vivo kinematics of unicondylar and bi‐unicondylar knee replacements. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1007/s00167-004-0565-x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.