CoChat

Does computer‐assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta‐analysis of randomized controlled trials?

Cheng, Tao, Zhao, Song, Peng, Xiaochun, Zhang, Xianlong · 2012 · Knee Surgery, Sports Traumatology, Arthroscopy
Cited by 242

The DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.

Abstract

Purpose: Computer‐assisted surgery has been proposed as a technique to improve implant alignment during total knee arthroplasty (TKA). However, there is still a debate over the accuracy of placing the femoral and tibial components using computer‐assisted systems in TKA. The aim of this study is to establish whether computer‐assisted surgery leads to superior mechanical leg axis and implant positioning than conventional technique in patients with primary TKA. Methods: Major electronic databases were systematically searched to identify relevant studies without language restriction. A meta‐analysis of 41 randomized controlled trials (RCTs) or quasi‐RCTs was performed in a random effects model. A subgroup analysis was conducted by type of navigation system to explore the clinical heterogeneity between these trials. The following radiographic parameters were used to compare computer‐assisted surgery with conventional technique: (1) mechanical leg axis, (2) femoral component coronal alignment, (3) tibial component coronal alignment, (4) femoral component sagittal alignment, and (5) tibial component sagittal alignment. Results: For the mechanical leg axis and coronal positioning of femoral and tibial components, there are statistically significant reductions in the number of patients with malalignment in the CAS group if the outlier cutoff value is ±3 or 2° in the coronal and sagittal planes, respectively. Subgroup analysis demonstrates that CT‐free navigation systems provide better alignment than conventional techniques in the coronal and sagittal alignment of femoral components within ±3 and 2°. If the outlier cutoff value for the tibial sagittal alignment is ±2°, the outlier percentages are higher in the CT‐free navigation group than in the conventional group. However, there was no significant difference in the tibial sagittal alignment at ±3°. Conclusion: Computer‐assisted surgery does improve mechanical leg axis and component orientation in TKAs. However, high‐quality RCTs are necessary to determine whether surgeons could use computer‐assisted techniques to achieve a targeted tibial slope in TKA. Level of evidence: Therapeutic study (Systematic review of Level I/II studies), Level II.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00167-011-1588-8

Cites

55 of 55 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 55 references

Cited by

See all 242

Metadata

Authors
Cheng, T., Zhao, S., Peng, X., & Zhang, X.
Venue
Knee Surgery, Sports Traumatology, Arthroscopy
Publisher
Wiley
Published
2011-07-06
Volume
20
Issue
7
Pages
1307-1322
ISSN
  • 0942-2056 (ISSN-L)
  • 1433-7347
OpenAlex
W2022087213
Cited by
242
References
55
FWCI
18.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Does computer‐assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta‐analysis of randomized controlled trials? https://app.cochat.ai/papers/10.1007/s00167-011-1588-8
The paper
Cheng, T., Zhao, S., Peng, X., & Zhang, X. (2012). Does computer‐assisted surgery improve postoperative leg alignment and implant positioning following total knee arthroplasty? A meta‐analysis of randomized controlled trials? Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1007/s00167-011-1588-8

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.