The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Alignment in total knee arthroplasty: A COMPARISON OF COMPUTER-ASSISTED SURGERY WITH THE CONVENTIONAL TECHNIQUE
Open accessAbstract
Restoration of neutral alignment of the leg is an important factor affecting the long-term results of total knee arthroplasty (TKA). Recent developments in computer-assisted surgery have focused on systems for improving TKA. In a prospective study two groups of 80 patients undergoing TKA had operations using either a computer-assisted navigation system or a conventional technique. Alignment of the leg and the orientation of components were determined on post-operative long-leg coronal and lateral films. The mechanical axis of the leg was significantly better in the computer-assisted group (96%, within ±3° varus/valgus) compared with the conventional group (78%, within ±3° varus/valgus). The coronal alignment of the femoral component was also more accurate in the computer-assisted group. Computer-assisted TKA gives a better correction of alignment of the leg and orientation of the components compared with the conventional technique. Potential benefits in the long-term outcome and functional improvement require further investigation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
Coronal alignment after total knee replacement
Jeffery, R., Morris, R., & Denham, R. (1991) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.73b5.1894655 · Cited by 1,100
Postoperative Alignment of Total Knee Replacement Its Effect on Survival
RITTER, M. A., FARIS, P. M., KEATING, E. M., & MEDING, J. B. (1994) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199402000-00021 · Cited by 1,008
Robertsson, O., Dunbar, M., Pehrsson, T., Knutson, K., & Lidgren, L. (2000) · Acta Orthopaedica Scandinavica · doi:10.1080/000164700317411852 · Cited by 674
Computer Assisted Knee Replacement
Delp, S. L., Stulberg, D. S., Davies, B., Picard, F., & Leitner, F. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199809000-00007 · Cited by 336
Ten-Year Evaluation of Geometric Total Knee Arthroplasty
RAND, J. A., & COVENTRY, M. B. (1988) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198807000-00022 · Cited by 276
Total condylar knee arthroplasty: Prosthetic component positioning and radiolucent lines
Hvid, I., & Nielsen, S. (1984) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678408992329 · Cited by 116
Cited by
Computer Assisted Knee Replacement Surgery: Is the Movement Mainstream?
Picard, F. (2014) · Orthopedic & Muscular System · doi:10.4172/2161-0533.1000153 · Cited by 23
Metadata
- Authors
- Bäthis, H., Perlick, L., Tingart, M., Lüring, C., Zurakowski, D., & Grifka, J.
- Venue
- The Journal of Bone and Joint Surgery. British volume
- Published
- 2004-07
- Volume
- 86-B
- Issue
- 5
- Pages
- 682-687
- ISSN
- 0301-620X (ISSN-L)
- 2044-5377
- OpenAlex
- W2067003172
- Cited by
- 667
- References
- 7
- FWCI
- 32.41
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Alignment in total knee arthroplasty: A COMPARISON OF COMPUTER-ASSISTED SURGERY WITH THE CONVENTIONAL TECHNIQUE. https://app.cochat.ai/papers/10.1302/0301-620x.86b5.14927
- The paper
- Bäthis, H., Perlick, L., Tingart, M., Lüring, C., Zurakowski, D., & Grifka, J. (2004). Alignment in total knee arthroplasty: A COMPARISON OF COMPUTER-ASSISTED SURGERY WITH THE CONVENTIONAL TECHNIQUE. The Journal of Bone and Joint Surgery. British volume. https://doi.org/10.1302/0301-620x.86b5.14927
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.