CoChat

A metrological inspection method using micro-CT for the analysis of drilled holes in CFRP and titanium stacks

Open access
Kourra, Nadia, Warnett, Jason M., Attridge, Alex, Dahnel, Aishah, Ascroft, Helen, Barnes, Stuart, Williams, Mark A. · 2017 · The International Journal of Advanced Manufacturing Technology

The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.

Abstract

This paper demonstrates a novel method that combines X-ray computed tomography (CT) and image processing for investigating two materials with significantly different densities. CT is increasingly used in industrial applications of inspecting materials and defects. The limitations of the system and data reconstruction are continuously researched so as to improve the quality of the results. One of the most common issues in CT is beam hardening, frequently experienced in multi-material scanning. The materials examined to demonstrate the method are carbon fibre reinforced polymers (CFRP) and titanium alloy Ti6Al4V, often used in combination in industry to optimise the weight to strength ratio. The assembly of the materials is usually achieved by bolting and riveting, which requires drilling through the two materials together. The machining of these materials is difficult due to their higher specific properties and as a result tool wear is always an issue. CFRPs properties depend on the nature, orientation and bond of the fibres and as a result drilling affects their service life. The results of the method ensure the quality of the drilled holes by measuring the variation of the maximum diameter, circularity, positioning of the hole and an examining the entrance delamination and exit burrs by image processing.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00170-016-8691-4

Cites

50 of 50 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 The grey value of each pixel demonstrates the attenuation level of x-rays from matter
Fig. 1 The grey value of each pixel demonstrates the attenuation level of x-rays from matterCC-BY · From the PDF
Fig. 2 Experimental drilling set-up of conventional and ultrasonic drilling
Fig. 2 Experimental drilling set-up of conventional and ultrasonic drillingCC-BY · From the PDF
Fig. 3 Voxel rescaling according to CMM measurements. The centre to centre distance of the prescribed circles shown are scaled to the actual canter to centre distance measured by optical CMM
Fig. 3 Voxel rescaling according to CMM measurements. The centre to centre distance of the prescribed circles shown are scaled to the actual canter to centre distance measured by optical CMMCC-BY · From the PDF
Fig. 4 X-ray set-up. In order to achieve maximum resolution, the part needs to be place as close to the X-ray source as possible while keeping the part in the field of view
Fig. 4 X-ray set-up. In order to achieve maximum resolution, the part needs to be place as close to the X-ray source as possible while keeping the part in the field of viewCC-BY · From the PDF
Image 5
CC-BY · From the PDF
Fig. 6 Examination of the join show extreme porosity. Pores are represented as black and glass particles as white
Fig. 6 Examination of the join show extreme porosity. Pores are represented as black and glass particles as whiteCC-BY · From the PDF
Image 7
CC-BY · From the PDF
Fig. 8 Maximum diameter and maximum radius per slide. The different sections of the hole are identified as CFRP, Join and Ti6Al4V. Results for ( a ) 10th drilled hole and ( b ) 50th drilled hole
Fig. 8 Maximum diameter and maximum radius per slide. The different sections of the hole are identified as CFRP, Join and Ti6Al4V. Results for ( a ) 10th drilled hole and ( b ) 50th drilled holeCC-BY · From the PDF
Fig. 9 The results of the first holes for both CD and UAD of the 10th holes. The results shown are per slice and the entrance surface is located at 0 mm and exit surface at 8.4 mm. Tolerances are given for diameter, circularity and positioning. Panel a shows the maximum
Fig. 9 The results of the first holes for both CD and UAD of the 10th holes. The results shown are per slice and the entrance surface is located at 0 mm and exit surface at 8.4 mm. Tolerances are given for diameter, circularity and positioning. Panel a shows the maximumCC-BY · From the PDF
Fig. 10 The results of the last holes for both CD and UAD of the 50th holes. The results shown are per slice and the entrance surface is located at 0 mm and exit surface at 8.4 mm. Tolerances are given for diameter, circularity and positioning. Panel a shows
Fig. 10 The results of the last holes for both CD and UAD of the 50th holes. The results shown are per slice and the entrance surface is located at 0 mm and exit surface at 8.4 mm. Tolerances are given for diameter, circularity and positioning. Panel a showsCC-BY · From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 50 references

Research works printed but not linked: 3

  1. Herman GT (2009) Fundamentals of computed tomography - image reconstruction from projections. Springer, London 3. Kruth JP, Bartscher M, Carmignato S, Schmitt R, De ChiffreL, Weckenmann A (2011) Computed tomography for dimen- sional metrology. CIRP Ann 2011 -Manuf Technol 60:821- 842
  2. Weib D, Lonardoni R, Deffner A, Kuhn C (2012) Geometric image distortion in flat-panel X-ray detectos and its influence on the accuracy of CT-based dimensional measurements, iCT Conference Austria
  3. VDI/VDE (2010) Computed tomography in dimensional mea- surements. Measurement procedure and comparability VDI/VDE 2630 Part 1:4

Cited by

Metadata

Authors
Kourra, N., Warnett, J. M., Attridge, A., Dahnel, A., Ascroft, H., Barnes, S., & Williams, M. A.
Affiliations
University of Warwick (GB)
Corresponding author
Kourra, Nadia
Venue
The International Journal of Advanced Manufacturing Technology
Published
2016-05-14
Volume
88
Issue
5-8
Pages
1417-1427
ISSN
  • 0268-3768 (ISSN-L)
  • 1433-3015
OpenAlex
W2362243662
Cited by
11
References
50
Citations by year
2026: 2 · 2025: 2 · 2024: 2 · 2022: 1 · 2020: 1 · 2019: 1 · 2017: 1 · 2016: 1
FWCI
0.48
Type
journal article
Language
en
Open access
Locations
  • The International Journal of Advanced Manufacturing Technology (publishedVersion, cc-by)
  • The International Islamic University Malaysia Repository (The International Islamic University Malaysia) (acceptedVersion)
  • Warwick Research Archive Portal (University of Warwick) (acceptedVersion)
Funders
Engineering and Physical Sciences Research Council
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced X-ray and CT Imaging
  • Physical Sciences › Engineering › Industrial and Manufacturing Engineering › Industrial Vision Systems and Defect Detection
  • Physical Sciences › Engineering › Mechanical Engineering › Advanced Measurement and Metrology Techniques
Keywords
drilled holes, carbon fiber reinforced polymer, Ti-6Al-4V titanium alloy, hybrid composites, computed tomography, beam hardening, hole diameter measurement, circularity, burr formation, delamination, image processing, tool wear

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.