Cited by 131Pelvic floor disorders treatmentsHernia repair and managementUreteral procedures and complications

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Anatomy of the obturator region: relations to a trans-obturator sling

Whiteside, James L., Walters, Mark D.·2003·International Urogynecology Journal and Pelvic Floor Dysfunction

Abstract

Our objective was to determine the relationships between a trans-obturator sling and anatomic structures within the obturator region. The obturator regions of six cadavers were dissected and distances from the mid-point of the ischiopubic ramus to the muscles, nerves, and vessels of the region were measured. A trans-obturator sling was placed and distances from the device to the same anatomic structures were determined. Four additional cadavers were dissected to determine the device route of passage. The obturator canal is on average 4.4 cm from the midpoint of the ischiopubic rami. The trans-obturator sling passes on average 2.4 cm inferior-medial to the obturator canal. The anterior and posterior divisions of the obturator nerve are on average 3.4 and 2.8 cm, respectively, from a passed trans-obturator device. The device passed on average 1.1 cm from the most medial branch of the obturator vessels. Vascular and nerve structures are within 1-3 cm of the path of any device passed through the obturator foramen. A trans-obturator sling risks injury to these structures, although the small caliber of the vessels and the confined space in which they would bleed make the consequences of injury uncertain.

Overview

Integrity signals

Registry

Crossref · 10.1007/s00192-004-1143-y

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Metadata

Authors
Whiteside, J. L., & Walters, M. D.
Affiliations
Cleveland Clinic (US)
Corresponding author
Whiteside, James L.
Venue
International Urogynecology Journal and Pelvic Floor Dysfunction
Published
2003-07-05
Volume
-1
Issue
1
Pages
1-1
ISSN
  • 0937-3462 (ISSN-L)
  • 1433-3023
OpenAlex
W1965119733
Cited by
131
References
4
Citations by year
2026: 2 · 2025: 1 · 2024: 1 · 2023: 1 · 2022: 5 · 2021: 7 · 2020: 5 · 2019: 4 · 2018: 4 · 2017: 3 · 2016: 5 · 2015: 4 · 2014: 8 · 2013: 6 · 2012: 9
FWCI
3.09
Type
journal article
Language
en
Open access
closed
Locations
  • International Urogynecology Journal (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Urology › Pelvic floor disorders treatments
  • Health Sciences › Medicine › Surgery › Hernia repair and management
  • Health Sciences › Medicine › Urology › Ureteral procedures and complications
Keywords
obturator canal, obturator nerve, pelvic organ prolapse surgery, cadaveric dissection
MeSH terms
Cadaver, Dissection, Female, Hernia, Obturator, Humans, Obturator Nerve, Perineum, Sensitivity and Specificity, Pelvic Floor, Muscle, Skeletal

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review