Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 159 of the 160 references it cites were found in a registry or an index.

Markers of bone turnover for the prediction of fracture risk and monitoring of osteoporosis treatment: a need for international reference standards

for the IOF-IFCC Bone Marker Standards Working Group, Vasikaran, S., Eastell, R., Bruyère, O., Foldes, A. J., Garnero, P., Griesmacher, A., McClung, M., Morris, H. A., Silverman, S., Trenti, T., Wahl, D. A., Cooper, C., Kanis, J. A. · 2011 · Osteoporosis International

Abstract

Unlabelled The International Osteoporosis Foundation (IOF) and the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) recommend that a marker of bone formation (serum procollagen type I N propeptide, s-PINP) and a marker of bone resorption (serum C-terminal telopeptide of type I collagen, s-CTX) are used as reference analytes for bone turnover markers in clinical studies.Introduction Bone turnover markers (BTM) predict fracture risk, and treatment-induced changes in specific markers account for a substantial proportion of fracture risk reduction. The aims of this report were to determine their clinical potential in the prediction of fracture risk and for monitoring the treatment of osteoporosis and to set an appropriate research agenda.Methods Evidence from prospective studies was gathered through literature review of the PUBMED database between the years 2000 and 2010 and the systematic review of the Agency for Healthcare Research and Quality up to 2001.Results High levels of BTMs may predict fracture risk independently from bone mineral density in postmenopausal women. They have been used for this purpose in clinical practice for many years, but there is still a need for stronger evidence on which to base practice. BTMs provide pharmacodynamic information on the response to osteoporosis treatment, and as a result, they are widely used for monitoring treatment in the individual. However, their clinical value for monitoring is limited by inadequate appreciation of the sources of variability, by limited data for comparison of treatments using the same BTM and by inadequate quality control. IOF/IFCC recommend one bone formation marker (s-PINP) and one bone resorption marker (s-CTX) to be used as reference markers and measured by standardised assays in observational and intervention studies in order to compare the performance of alternatives and to enlarge the international experience of the application of markers to clinical medicine.Conclusion BTM hold promise in fracture risk prediction and for monitoring treatment. Uncertainties over their clinical use can be in part resolved by adopting international reference standards.

Overview

Integrity signals

Registry

Crossref · 10.1007/s00198-010-1501-1

Cites

159 of 159 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 160 references

Research works printed but not linked: 1

  1. Lorenc R, Głuszko P, Karczmarewicz E, Księżopolska-Orłowska K, Misiorowski W, Franek E, Horst-Sikorska W, Kaleta M, Męczekalski B et al (2007) Recommendations on the diagnosis and treatment of osteoporosis. Reducing the incidence of fractures through effective prevention and treatment. Terapia 9:11–39

Cited by

See all 1,212

Metadata

Authors
for the IOF-IFCC Bone Marker Standards Working Group, Vasikaran, S., Eastell, R., Bruyère, O., Foldes, A. J., Garnero, P., Griesmacher, A., McClung, M., Morris, H. A., Silverman, S., Trenti, T., Wahl, D. A., Cooper, C., & Kanis, J. A.
Affiliations
  • The University of Western Australia (AU)
  • Royal Perth Hospital (AU)
  • University of Liège (BE)
  • Inserm (FR)
  • Innsbruck Medical University (AT)
  • University of South Australia (AU)
  • University of California, Los Angeles (US)
  • International Osteoporosis Foundation (CH)
  • Southampton General Hospital (GB)
  • University of Sheffield (GB)
Corresponding author
Cooper, C.
Venue
Osteoporosis International
Published
2010-12-24
Volume
22
Issue
2
Pages
391-420
ISSN
  • 0937-941X (ISSN-L)
  • 1433-2965
OpenAlex
W2005779589
Cited by
1,212
References
160
Citations by year
2026: 93 · 2025: 79 · 2024: 79 · 2023: 69 · 2022: 94 · 2021: 85 · 2020: 102 · 2019: 99 · 2018: 78 · 2017: 93 · 2016: 80 · 2015: 78 · 2014: 56 · 2013: 51 · 2012: 55
FWCI
40.28
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • Osteoporosis International (publishedVersion)
  • PubMed (publishedVersion)
  • UWA Profiles and Research Repository (UWA) (submittedVersion)
  • Research Bank (Australian Catholic University) (submittedVersion)
  • ePrints Soton (University of Southampton) (submittedVersion)
  • Open Repository and Bibliography (University of Liège) (submittedVersion)
Funders
  • National Institute for Health and Care Research (NF-SI-0508-10082)
  • International Osteoporosis Foundation
  • Abbott Diagnostics
Topics
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
  • Health Sciences › Medicine › Oncology › Bone health and treatments
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Bone Metabolism and Diseases
Keywords
bone turnover markers, fracture risk prediction, osteoporosis treatment monitoring, C-terminal telopeptide of type I collagen, reference materials, postmenopausal women, bone mineral density, pharmacodynamic monitoring, assay variability, quality control
MeSH terms
Adult, Aged, Aged, 80 and over, Algorithms, Female, Humans, Male, Middle Aged, Osteoporosis, Reference Standards, Biomarkers, Bone Density, Osteoporosis, Postmenopausal, Bone Remodeling, Treatment Outcome, Risk Assessment, Osteoporotic Fractures

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Markers of bone turnover for the prediction of fracture risk and monitoring of osteoporosis treatment: a need for international reference standards. https://app.cochat.ai/papers/10.1007/s00198-010-1501-1
The paper
for the IOF-IFCC Bone Marker Standards Working Group, Vasikaran, S., Eastell, R., Bruyère, O., Foldes, A. J., Garnero, P., Griesmacher, A., McClung, M., Morris, H. A., Silverman, S., Trenti, T., Wahl, D. A., Cooper, C., & Kanis, J. A. (2011). Markers of bone turnover for the prediction of fracture risk and monitoring of osteoporosis treatment: a need for international reference standards. Osteoporosis International. https://doi.org/10.1007/s00198-010-1501-1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.