The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
National Bone Health Alliance Bone Turnover Marker Project: current practices and the need for US harmonization, standardization, and common reference ranges
Open accessAbstract
SummaryThis position paper reviews how the National Bone Health Alliance (NBHA) will execute a project to help assure health professionals of the clinical utility of bone turnover markers; the current clinical approaches concerning osteoporosis and the status and use of bone turnover markers in the USA; the rationale for focusing this effort around two specific bone turnover markers; the need to standardize bone marker sample collection procedures, reference ranges, and bone turnover marker assays in clinical laboratories; and the importance of harmonization for future research of bone turnover markers.IntroductionOsteoporosis is a major global health problem, with the prevalence and incidence of osteoporosis for at-risk populations estimated to be 44 million Americans. The potential of bone markers as an additional tool for health care professionals to improve patient outcomes and impact morbidity and mortality is crucial in providing better health care and addressing rising health care costs. This need to advance the field of bone turnover markers has been recognized by a number of organizations, including the International Osteoporosis Foundation (IOF), National Osteoporosis Foundation, International Federation of Clinical Chemistry, and Laboratory Medicine (IFCC), and the NBHA.MethodsThis position paper elucidates how this project will standardize bone turnover marker sample collection procedures in the USA, establish a USA reference range for one bone formation (serum procollagen type I N propeptide, s-PINP) and one bone resorption (serum C-terminal telopeptide of type I collagen, s-CTX) marker, and standardize bone turnover marker assays used in clinical laboratories. This effort will allow clinicians from the USA to have confidence in their use of bone turnover markers to help monitor osteoporosis treatment and assess future fracture risk. This project builds on the recommendations of the IOF/IFCC Bone Marker Standards Working Group by developing USA reference standards for s-PINP and s-CTX, the markers identified as most promising for use as reference markers.ResultsThe goals of this project will be realized through the NBHA and will include its governmental, academic, for-profit, and non-profit sector stakeholders as well as major academic and commercial laboratories. Upon completion, a parallel effort will be pursued to make bone turnover marker measurements reliable and accepted by all health care professionals for facilitating treatment decisions and ultimately be reimbursed by all health insurance payers.ConclusionsSuccessful completion of this project will help assure health professionals from the USA of the clinical utility of bone turnover markers and ties in with the parallel effort of the IOF/IFCC to develop worldwide bone turnover reference ranges.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Incidence and Economic Burden of Osteoporosis-Related Fractures in the United States, 2005–2025
Burge, R., Dawson-Hughes, B., Solomon, D. H., Wong, J. B., King, A., & Tosteson, A. (2007) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.061113 · Cited by 4,026
Chesnut, C. H., Skag, A., Christiansen, C., Recker, R., Stakkestad, J. A., Hoiseth, A., Felsenberg, D., Huss, H., Gilbride, J., Schimmer, R. C., et al. (2004) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.040325 · Cited by 1,229
for the IOF-IFCC Bone Marker Standards Working Group, Vasikaran, S., Eastell, R., Bruyère, O., Foldes, A. J., Garnero, P., Griesmacher, A., McClung, M., Morris, H. A., Silverman, S., et al. (2011) · Osteoporosis International · doi:10.1007/s00198-010-1501-1 · Cited by 1,212
Self-citationLittle, R. R., Rohlfing, C. L., & Sacks, D. B. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.148841 · Cited by 365
Cited by
Camacho, P. M., Petak, S. M., Binkley, N., Diab, D. L., Eldeiry, L. S., Farooki, A., Harris, S. T., Hurley, D. L., Kelly, J., Lewiecki, E. M., et al. (2020) · Endocrine Practice · doi:10.4158/gl-2020-0524suppl · Cited by 1,182
Camacho, P. M., Petak, S. M., Binkley, N., Clarke, B. L., Harris, S. T., Hurley, D. L., Kleerekoper, M., Lewiecki, E. M., Miller, P. D., Narula, H. S., et al. (2016) · Endocrine Practice · doi:10.4158/ep161435.esgl · Cited by 1,140
Self-citationCamacho, P. M., Petak, S. M., Binkley, N., Clarke, B. L., Harris, S. T., Hurley, D. L., Kleerekoper, M., Lewiecki, E. M., Miller, P. D., Narula, H. S., et al. (2016) · Endocrine Practice · doi:10.4158/ep161435.gl · Cited by 478
Self-citationBone Turnover Markers: Basic Biology to Clinical Applications
Schini, M., Vilaca, T., Gossiel, F., Salam, S., & Eastell, R. (2023) · Endocrine Reviews · doi:10.1210/endrev/bnac031 · Cited by 387
The clinical utility of bone marker measurements in osteoporosis
Wheater, G., Elshahaly, M., Tuck, S. P., Datta, H. K., & van Laar, J. M. (2013) · Journal of Translational Medicine · doi:10.1186/1479-5876-11-201 · Cited by 322
Metadata
- Authors
- Bauer, D., Krege, J., Lane, N., Leary, E., Libanati, C., Miller, P., Myers, G., Silverman, S., Vesper, H. W., Lee, D., Payette, M., & Randall, S.
- Venue
- Osteoporosis International
- Published
- 2012-07-14
- Volume
- 23
- Issue
- 10
- Pages
- 2425-2433
- ISSN
- 0937-941X (ISSN-L)
- 1433-2965
- OpenAlex
- W2035749891
- Cited by
- 158
- References
- 4
- FWCI
- 10.43
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: National Bone Health Alliance Bone Turnover Marker Project: current practices and the need for US harmonization, standardization, and common reference ranges. https://app.cochat.ai/papers/10.1007/s00198-012-2049-z
- The paper
- Bauer, D., Krege, J., Lane, N., Leary, E., Libanati, C., Miller, P., Myers, G., Silverman, S., Vesper, H. W., Lee, D., Payette, M., & Randall, S. (2012). National Bone Health Alliance Bone Turnover Marker Project: current practices and the need for US harmonization, standardization, and common reference ranges. Osteoporosis International. https://doi.org/10.1007/s00198-012-2049-z
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.