The DOI matches its Crossref record; 90 of the 90 references it cites were found in a registry or an index.
Guidelines for the assessment of bone density and microarchitecture in vivo using high-resolution peripheral quantitative computed tomography
Open accessAbstract
Introduction The application of high-resolution peripheral quantitative computed tomography (HR-pQCT) to assess bone microarchitecture has grown rapidly since its introduction in 2005. As the use of HR-pQCT for clinical research continues to grow, there is an urgent need to form a consensus on imaging and analysis methodologies so that studies can be appropriately compared. In addition, with the recent introduction of the second-generation HrpQCT, which differs from the first-generation HR-pQCT in scan region, resolution, and morphological measurement techniques, there is a need for guidelines on appropriate reporting of results and considerations as the field adopts newer systems. Methods A joint working group between the International Osteoporosis Foundation, American Society of Bone and Mineral Research, and European Calcified Tissue Society convened in person and by teleconference over several years to produce the guidelines and recommendations presented in this document. Results An overview and discussion is provided for (1) standardized protocol for imaging distal radius and tibia sites using HR-pQCT, with the importance of quality control and operator training discussed; (2) standardized terminology and recommendations on reporting results; (3) factors influencing accuracy and precision error, with considerations for longitudinal and multi-center study designs; and finally (4) comparison between scanner generations and other high-resolution CT systems. Conclusion This article addresses the need for standardization of HR-pQCT imaging techniques and terminology, provides guidance on interpretation and reporting of results, and discusses unresolved issues in the field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Controlling the False Discovery Rate: A Practical and Powerful Approach to Multiple Testing
Benjamini, Y., & Hochberg, Y. (1995) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1995.tb02031.x · Cited by 109,482
Hildebrand, T., Laib, A., Müller, R., Dequeker, J., & Rüegsegger, P. (1999) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1999.14.7.1167 · Cited by 1,303
Boutroy, S., Bouxsein, M. L., Munoz, F., & Delmas, P. D. (2005) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2005-1258 · Cited by 1,192
Self-citationQuantification of Bone Microarchitecture with the Structure Model Index
HILDEBRAND, T., & RÜEGSEGGER, P. (1997) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/01495739708936692 · Cited by 1,051
van Rietbergen, B., Weinans, H., Huiskes, R., & Odgaard, A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)80008-5 · Cited by 865
Quantification of connectivity in cancellous bone, with special emphasis on 3-D reconstructions
Odgaard, A., & Gundersen, H. J. G. (1993) · Bone · doi:10.1016/8756-3282(93)90245-6 · Cited by 680
Pistoia, W., van Rietbergen, B., Lochmüller, E.-M., Lill, C. A., Eckstein, F., & Rüegsegger, P. (2002) · Bone · doi:10.1016/s8756-3282(02)00736-6 · Cited by 643
Buie, H. R., Campbell, G. M., Klinck, R. J., MacNeil, J. A., & Boyd, S. K. (2007) · Bone · doi:10.1016/j.bone.2007.07.007 · Cited by 601
Self-citationThe quantitative morphology of anisotropic trabecular bone
Whitehouse, W. J. (1974) · Journal of Microscopy · doi:10.1111/j.1365-2818.1974.tb03878.x · Cited by 579
Burghardt, A. J., Buie, H. R., Laib, A., Majumdar, S., & Boyd, S. K. (2010) · Bone · doi:10.1016/j.bone.2010.05.034 · Cited by 459
Self-citation
Research works printed but not linked: 22
- Gabel L, Macdonald HM, Nettlefold LA, McKay HA (2018) Sex-, ethnic-, and age-specific centile curves for pQCT- and HR-pQCT-derived measures of bone structure and strength in adolescents and young adults. J Bone Miner Res 33:987–1000 · doi:10.1002/jbmr.3399
- Boyd SK, Burt LA, Sevick LK, Hanley DA (2015) The relationship between serum 25(OH)D and bone density and microarchitecture as measured by HR-pQCT. Osteoporos Int 26:2375–2380 · doi:10.1007/s00198-015-3110-5
- Stauber M, Müller R (2008) Micro-computed tomography: a method for the non-destructive evaluation of the three-dimensional structure of biological specimens. Methods Mol Biol 455:273–292 · doi:10.1007/978-1-59745-104-8_19
- Bonaretti S, Majumdar S, Lang TF, Khosla S, Burghardt AJ (2017) The comparability of HR-pQCT bone measurements is improved by scanning anatomically standardized regions. Osteoporos Int 28:2115–2128 · doi:10.1007/s00198-017-4010-7
- Boyd SK (2008) Site-specific variation of bone micro-architecture in the distal radius and tibia. J Clin Densitom 11:424–430 · doi:10.1016/j.jocd.2007.12.013
- Bonaretti S, Vilayphiou N, Chan CM, Yu A, Nishiyama K, Liu D, Boutroy S, Ghasem-Zadeh A, Boyd SK, Chapurlat R, McKay H, Shane E, Bouxsein ML, Black DM, Majumdar S, Orwoll ES, Lang TF, Khosla S, Burghardt AJ (2017) Operator variability in scan positioning is a major component of HR-pQCT precision error and is reduced by standardized training. Osteoporos Int 28:245–257 · doi:10.1007/s00198-016-3705-5
- Engelke K, Stampa B, Timm W, Dardzinski B, de Papp AE, Genant HK, Fuerst T (2012) Short-term in vivo precision of BMD and parameters of trabecular architecture at the distal forearm and tibia. Osteoporos Int 23:2151–2158 · doi:10.1007/s00198-011-1829-1
- de Waard EAC, Sarodnik C, Pennings A, de Jong JJA, Savelberg HHCM, van Geel TA, van der Kallen CJ, Stehouwer CDA, Schram MT, Schaper N, Dagnelie PC, Geusens PPMM, Koster A, van Rietbergen B, van den Bergh JPW (2018) Reliability of HR-pQCT derived cortical bone structural parameters when using uncorrected instead of corrected automatically generated endocortical contours in a cross-sectional study: the Maastricht Study. Calcif Tissue Int 103:252–265 · doi:10.1007/s00223-018-0416-2
- de Jong JJ, Willems PC, Arts JJ, Bours SG, Brink PR, van Geel TA, Poeze M, Geusens PP, van Rietbergen B, van den Bergh JP (2014) Assessment of the healing process in distal radius fractures by high resolution peripheral quantitative computed tomography. Bone 64:65–74 · doi:10.1016/j.bone.2014.03.043
- Mueller TL, Christen D, Sandercott S, Boyd SK, van Rietbergen B, Eckstein F, Lochmuller EM, Muller R, van Lenthe GH (2011) Computational finite element bone mechanics accurately predicts mechanical competence in the human radius of an elderly population. Bone 48:1232–1238 · doi:10.1016/j.bone.2011.02.022
- Paggiosi MA, Eastell R, Walsh JS (2014) Precision of high-resolution peripheral quantitative computed tomography measurement variables: influence of gender, examination site, and age. Calcif Tissue Int 94:191–201 · doi:10.1007/s00223-013-9798-3
- de Jong JJA, Christen P, Plett RM, Chapurlat R, Geusens PP, van den Bergh JPW, Müller R, van Rietbergen B (2017) Feasibility of rigid 3D image registration of high-resolution peripheral quantitative computed tomography images of healing distal radius fractures. PLoS One 12:e0179413
- Burghardt AJ, Pialat JB, Kazakia GJ, Boutroy S, Engelke K, Patsch JM, Valentinitsch A, Liu D, Szabo E, Bogado CE, Zanchetta MB, McKay HA, Shane E, Boyd SK, Bouxsein ML, Chapurlat R, Khosla S, Majumdar S (2013) Multicenter precision of cortical and trabecular bone quality measures assessed by high-resolution peripheral quantitative computed tomography. J Bone Miner Res 28:524–536 · doi:10.1002/jbmr.1795
- de Jong JJ, Arts JJ, Meyer U, Willems PC, Geusens PP, van den Bergh JP, van Rietbergen B (2016) Effect of a cast on short-term reproducibility and bone parameters obtained from HR-pQCT measurements at the distal end of the radius. J Bone Joint Surg Am 98:356–362 · doi:10.2106/jbjs.o.00127
- Whittier DE, Manske SL, Boyd SK, Schneider PS (2018) The correction of systematic error due to plaster and fiberglass casts on HR-pQCT bone parameters measured in vivo at the distal radius. J Clin Densitom · doi:10.1016/j.jocd.2018.11.005
- Klintstrom E, Smedby O, Moreno R, Brismar TB (2014) Trabecular bone structure parameters from 3D image processing of clinical multi-slice and cone-beam computed tomography data. Skelet Radiol 43:197–204 · doi:10.1007/s00256-013-1766-5
- Mys K, Varga P, Gueorguiev B, Hemmatian H, Stockmans F, van Lenthe GH (2019) Correlation between cone-beam computed tomography and high-resolution peripheral computed tomography for assessment of wrist bone microstructure. J Bone Miner Res 34:867–874 · doi:10.1002/jbmr.3673
- Brehler M, Cao Q, Moseley KF, Osgood G, Morris C, Demehri S, Yorkston J, Siewerdsen JH, Zbijewski W (2018) Robust quantitative assessment of trabecular microarchitecture in extremity cone-beam CT using optimized segmentation algorithms. Proc SPIE Int Soc Opt Eng 10578: · doi:10.1117/12.2293346
- Kawalilak CE, Bunyamin AT, Bjorkman KM, Johnston JD, Kontulainen SA (2017) Precision of bone density and micro-architectural properties at the distal radius and tibia in children: an HR-pQCT study. Osteoporos Int 28:3189–3197 · doi:10.1007/s00198-017-4185-y
- Nagaraj S, Finzel S, Stok KS, Barnabe C, Collaboration S (2016) High-resolution peripheral quantitative computed tomography imaging in the assessment of periarticular bone of metacarpophalangeal and wrist joints. J Rheumatol 43:1921–1934 · doi:10.3899/jrheum.160647
- Kroker A, Zhu Y, Manske SL, Barber R, Mohtadi N, Boyd SK (2017) Quantitative in vivo assessment of bone microarchitecture in the human knee using HR-pQCT. Bone 97:43–48 · doi:10.1016/j.bone.2016.12.015
- Stok KS, Finzel S, Burghardt AJ, Conaghan PG, Barnabe C, Collaboration S (2017) The SPECTRA collaboration OMERACT special interest group: current research and future directions. J Rheumatol 44:1911–1915 · doi:10.3899/jrheum.161197
Cited by
Beavers, K. M., Cortes, T. M., Foy, C. M., Dinkla, L., Reyes San Martin, F., Ard, J. D., Serra, M. C., & Beavers, D. P. (2025) · Obesity · doi:10.1002/oby.24172 · Cited by 41
Male Runners With Lower Energy Availability Have Impaired Skeletal Integrity Compared to Nonathletes
Haines, M. S., Kaur, S., Scarff, G., Lauze, M., Gerweck, A., Slattery, M., Oreskovic, N. M., Ackerman, K. E., Tenforde, A. S., Popp, K. L., et al. (2023) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/clinem/dgad215 · Cited by 9
Self-citation
Metadata
- Authors
- Whittier, D. E., Boyd, S. K., Burghardt, A. J., Paccou, J., Ghasem-Zadeh, A., Chapurlat, R., Engelke, K., & Bouxsein, M. L.
- Venue
- Osteoporosis International
- Published
- 2020-05-26
- Volume
- 31
- Issue
- 9
- Pages
- 1607-1627
- ISSN
- 0937-941X (ISSN-L)
- 1433-2965
- OpenAlex
- W3032874343
- Cited by
- 370
- References
- 90
- FWCI
- 38.68
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- www.springer.com/tdm (tdm)
- www.springer.com/tdm (vor)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Guidelines for the assessment of bone density and microarchitecture in vivo using high-resolution peripheral quantitative computed tomography. https://app.cochat.ai/papers/10.1007/s00198-020-05438-5
- The paper
- Whittier, D. E., Boyd, S. K., Burghardt, A. J., Paccou, J., Ghasem-Zadeh, A., Chapurlat, R., Engelke, K., & Bouxsein, M. L. (2020). Guidelines for the assessment of bone density and microarchitecture in vivo using high-resolution peripheral quantitative computed tomography. Osteoporosis International. https://doi.org/10.1007/s00198-020-05438-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.