Enhancing Power System Stability: An Innovative Approach Using Coordination of Fopid Controller for Pss and Svc Facts Device with Mfo Algorithm

Open access

Abstract

This paper investigates an optimal methodology for mitigating low-frequency oscillation concerns in power systems. The study explores the synergistic integration of a power system stabilizer (PSS) and a flexible alternating current transmission system (FACTS) to formulate an intelligent controller. A comprehensive analysis encompasses various PSS design strategies, including lead-lag (LL), proportional-derivative-integral (PID), and fractional-order proportional-integral-derivative (FOPID) controllers. The FACTS device selected for this investigation is a static VAR compensator (SVC), highlighting the exceptional efficacy of FOPID-based PSS over alternative strategies with a power oscillation damper. The study extends its scope to encompass a comparative assessment of two distinct optimization algorithms: the moth flame optimization (MFO) and the antlion optimization (ALO). The research is conducted using a single-machine infinite bus power system (SMIB) as the case study platform. A total of four diverse test scenarios are executed under varying operating conditions. The evaluation of the developed method employs six distinct performance indices to investigate the developed controller thoroughly. The outcomes reveal that the MFO-optimized FOPID-PSS and SVC controller outperforms other control schemes. This optimized configuration demonstrates substantial improvements across all performance indices. These findings underscore the superior capabilities of the proposed approach in enhancing power system stability and performance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00202-023-02051-7

Cites

59 of 59 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 59 references

Research works printed but not linked: 9

  1. H. R. Heydari, H. S. Ali, B. Mahani, and R. Dahim, “Coordinated Designing Between Pss and Svc Pod Controller Using De Algorithm,” International Journal on Technical and Physical Problems of Engineering, no. September, 2014.
  2. E. S. Ali and S. M. Abd-Elazim, (2014) Power system stability enhancement via new coordinated design of PSSs and SVC. WSEAS Transactions on Power Systems 9
  3. Shin Mei RN, Sulaiman MH, Daniyal H, Mustaffa Z (2018) Application of moth-flame optimizer and ant lion optimizer to solve optimal reactive power dispatch problems. J Telecommun Electr Comput Eng 10:1–2
  4. Ibrahim NMA, Elnaghi BE, Ibrahem HA, Talaat HEA (2018) Modified particle swarm optimization based on lead-lag power system stabilizer for improve stability in multi-machine power system. Int J Electr Eng Inform 11(1):161–182. https://doi.org/10.15676/ijeei.2019.11.1.10 · DOI
  5. F. G. Martins, “Tuning PID controllers using the ITAE criterion,” International Journal of Engineering Education, vol. 21, no. 5 PART I AND II, 2005.
  6. H. Shayeghi, H. A. Shayanfar, S. Asefi, and A. Younesi, Optimal tuning and comparison of different power system stabilizers using different performance indices Via Jaya Algorithm. In: Int’l conf. scientific computing (CSC’16), Computer engineering and applied computing (WorldComp), 2016, p. 34.
  7. Sayed Y, Ahmed A-H, Elghaffar AA, Eltamaly A (2019) Multi-shunt VAR compensation SVC and STATCOM for enhance the power system quality. J Electr Eng 19:12
  8. Biswas MM, Das KK (2011) Voltage level improving by using static VAR compensator (SVC). Global J Res Eng 11(5):13–18
  9. Bibhuti BP and Bidyadhar R, MFO Ptimized fractional order based controller on power system stability. In: proceedings of engineering and technology innovation, Taiwan: Association of Engineering and Technology Innovation, Apr. 2018, pp. 46–59.

Cited by

See all 28

Metadata

Authors
Ibrahim, N. M. A., El-said, E. A., Attia, H. E. M., & Hemade, B. A.
Affiliations
Suez University (EG)
Corresponding author
Ibrahim, Nader M. A.
Venue
Electrical Engineering
Published
2023-10-20
Volume
106
Issue
3
Pages
2265-2283
ISSN
  • 0003-9039 (ISSN-L)
  • 0948-7921
  • 1432-0487
OpenAlex
W4387812575
Cited by
28
References
59
Citations by year
2026: 5 · 2025: 10 · 2024: 12 · 2023: 1
FWCI
2.08
Type
journal article
Language
en
Open access
Licence
Locations
Electrical Engineering (publishedVersion, cc-by)
Funders
Suez University
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Power System Optimization and Stability
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Frequency Control in Power Systems
  • Physical Sciences › Engineering › Control and Systems Engineering › Advanced Control Systems Design
Keywords
power system stability, low frequency oscillation damping, power system stabilizer, static VAR compensator, FACTS devices, fractional order PID controller, moth-flame optimization, ant lion optimizer, controller tuning, single machine infinite bus, lead-lag controller, PID controller

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Enhancing Power System Stability: An Innovative Approach Using Coordination of Fopid Controller for Pss and Svc Facts Device with Mfo Algorithm. https://app.cochat.ai/papers/10.1007/s00202-023-02051-7
The paper
Ibrahim, N. M. A., El-said, E. A., Attia, H. E. M., & Hemade, B. A. (2024). Enhancing Power System Stability: An Innovative Approach Using Coordination of Fopid Controller for Pss and Svc Facts Device with Mfo Algorithm. Electrical Engineering. https://doi.org/10.1007/s00202-023-02051-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.