Design of new fractional order PI–fractional order PD cascade controller through dragonfly search algorithm for advanced load frequency control of power systems
Open accessThe DOI matches its Crossref record.
Abstract
Owing to integrating the dense range of distinct electric power sources, high volume of power generation units, abrupt and continuous changes in load demand, and rising utilization of power electronics, the electric power system (EPS) is striving for high-performance control schemes to counterwork the concerns depicted above. Additionally, it is highly creditable to have the controller structure as simple as possible from a viewpoint of practical implementation. Thus, this paper describes a virgin application of fractional order proportional integral–fractional order proportional derivative (FOPI–FOPD) cascade controller for load frequency control (LFC) of electric power generating systems. The proposed controller includes fractional order PI and fractional order PD controllers connected in cascade wherein orders of integrator (λ\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\lambda$$\end{document}) and differentiator (μ\documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}$$\mu$$\end{document}) may be fractional. The gains and fractional order parameters of the controller are concurrently tuned using recently proposed dragonfly search algorithm (DSA) by minimizing the integral time absolute error (ITAE) of frequency and tie-line power deviations. DSA is the mathematical model and computer simulation of static and dynamic swarming behaviors of dragonflies in nature, and its implementation in LFC studies is very rare, unveiling additional research gap to be bridged. Performance of the advocated approach is first explored on popular two-area thermal PS with/without governor dead band (GDB) nonlinearity and then on three-area hydrothermal PS with suitable generation rate constraints. To highlight the prominence and universality of our proposal, the work is extended to single-/multi-area multi-source EPSs. Several comparisons with DSA optimized FOPID controller and the relevant recent works for each test system indicate the contribution of proposed DSA optimized FOPI–FOPD cascade controller in alleviating settling time/undershoot/overshoot of frequency and tie-line power oscillations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ibrahim, N. M. A., El-said, E. A., Attia, H. E. M., & Hemade, B. A. (2024) · Electrical Engineering · doi:10.1007/s00202-023-02051-7 · Cited by 28
Metadata
- Authors
- Çelik, E.
- Venue
- Soft Computing
- Published
- 2020-08-05
- Volume
- 25
- Issue
- 2
- Pages
- 1193-1217
- ISSN
- 1432-7643 (ISSN-L)
- 1433-7479
- OpenAlex
- W3047596586
- Cited by
- 191
- References
- 0
- FWCI
- 7.76
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design of new fractional order PI–fractional order PD cascade controller through dragonfly search algorithm for advanced load frequency control of power systems. https://app.cochat.ai/papers/10.1007/s00500-020-05215-w
- The paper
- Çelik, E. (2021). Design of new fractional order PI–fractional order PD cascade controller through dragonfly search algorithm for advanced load frequency control of power systems. Soft Computing. https://doi.org/10.1007/s00500-020-05215-w
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.