The DOI matches its Crossref record; 92 of the 92 references it cites were found in a registry or an index.
Recent developments in solid-phase microextraction
Open accessAbstract
The main objective of this review is to describe the recent developments in solid-phase microextraction technology in food, environmental and bioanalytical chemistry applications. We briefly introduce the historical perspective on the very early work associated with the development of theoretical principles of SPME, but particular emphasis is placed on the more recent developments in the area of automation, high-throughput analysis, SPME method optimization approaches and construction of new SPME devices and their applications. The area of SPME automation for both GC and LC applications is particularly addressed in this review, as the most recent developments in this field have allowed the use of this technology for high-throughput applications. The development of new autosamplers with SPME compatibility and new-generation metal fibre assemblies has enhanced sample throughput for SPME-GC applications, the latter being attributed to the possibility of using the same fibre for several hundred extraction/injection cycles. For LC applications, high-throughput analysis (>1,000 samples per day) can be achieved for the first time with a multi-SPME autosampler which uses multi-well plate technology and allows SPME sample preparation of up to 96 samples in parallel. The development and evolution of new SPME devices such as needle trap, thin-film microextraction and cold-fibre headspace SPME have offered significant improvements in performance characteristics compared with the conventional fibre-SPME arrangement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solid phase microextraction : theory and practice
Pawliszyn, J. B. (1997) · Medical Entomology and Zoology · Cited by 2,277
Self-citationApplications of solid-phase microextraction in food analysis
Kataoka, H., Lord, H. L., & Pawliszyn, J. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00309-5 · Cited by 1,119
Self-citationApplications of Solid Phase Microextraction
(1999) · Royal Society of Chemistry eBooks · doi:10.1039/9781847550149 · Cited by 830
Evolution of solid-phase microextraction technology
Lord, H., & Pawliszyn, J. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00535-5 · Cited by 787
Self-citationDoehlert matrix: a chemometric tool for analytical chemistry—review
Ferreira, S. L. C., dos Santos, W. N. L., Quintella, C. M., Neto, B. B., & Bosque-Sendra, J. M. (2004) · Talanta · doi:10.1016/j.talanta.2004.01.015 · Cited by 617
Solid‐phase microextraction: a powerful sample preparation tool prior to mass spectrometric analysis
Vas, G., & Vékey, K. (2004) · Journal of Mass Spectrometry · doi:10.1002/jms.606 · Cited by 615
Prosen, H., & Zupančič-Kralj, L. (1999) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(98)00109-5 · Cited by 565
Recent advances in high-throughput quantitative bioanalysis by LC–MS/MS
Xu, R. N., Fan, L., Rieser, M. J., & El-Shourbagy, T. A. (2007) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2007.02.006 · Cited by 530
Recent technological advances for the determination of food authenticity
Reid, L. M., O'Donnell, C. P., & Downey, G. (2006) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2006.01.006 · Cited by 491
Bruheim, I., Liu, X., & Pawliszyn, J. (2003) · Analytical Chemistry · doi:10.1021/ac026162q · Cited by 471
Self-citationChong, S. L., Wang, D., Hayes, J. D., Wilhite, B. W., & Malik, A. (1997) · Analytical Chemistry · doi:10.1021/ac9703360 · Cited by 413
Sample preparation techniques for the determination of trace residues and contaminants in foods
Ridgway, K., Lalljie, S. P. D., & Smith, R. M. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.01.134 · Cited by 354
Quantitative Extraction Using an Internally Cooled Solid Phase Microextraction Device
Zhang, Z., & Pawliszyn, J. (1995) · Analytical Chemistry · doi:10.1021/ac00097a007 · Cited by 335
Self-citationKumar, A., Gaurav, Malik, A. K., Tewary, D. K., & Singh, B. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.01.028 · Cited by 330
Kataoka, H. (2002) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-002-1269-z · Cited by 285
Solid-phase microextraction in pesticide residue analysis
Beltran, J., López, F. J., & Hernández, F. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00142-4 · Cited by 282
Solid-Phase Microextraction Method Development for Headspace Analysis of Volatile Flavor Compounds
Roberts, D. D., Pollien, P., & Milo, C. (2000) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf991116l · Cited by 279
SPME in environmental analysis
Ouyang, G., & Pawliszyn, J. B. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0460-z · Cited by 272
Self-citationHead-space analysis in modern gas chromatography
Snow, N. H., & Slack, G. C. (2002) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(02)00802-6 · Cited by 263
New trends in sample preparation for clinical and pharmaceutical analysis
Kataoka, H. (2003) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(03)00402-3 · Cited by 261
A review of theoretical and practical aspects of solid-phase microextraction in food analysis
Wardencki, W., Michulec, M., & Curyło, J. (2004) · International Journal of Food Science and Technology · doi:10.1111/j.1365-2621.2004.00839.x · Cited by 208
Flavor, Fragrance, and Odor Analysis
(2001) · CRC Press eBooks · doi:10.1201/9780203908273 · Cited by 202
Recent applications of sample preparation techniques in food analysis
Buldini, P. L., Ricci, L., & Sharma, J. L. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)01335-3 · Cited by 202
Koziel, J. A., Odziemkowski, M., & Pawliszyn, J. (2001) · Analytical Chemistry · doi:10.1021/ac000835s · Cited by 200
Self-citationRecent developments in SPME for on-site analysis and monitoring
OUYANG, G., & PAWLISZYN, J. (2006) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2006.05.005 · Cited by 200
Self-citationApplication of solid-phase microextraction in analytical toxicology
Pragst, F. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1289-9 · Cited by 198
Field air analysis with SPME device
Koziel, J., Jia, M., Khaled, A., Noah, J., & Pawliszyn, J. (1999) · Analytica Chimica Acta · doi:10.1016/s0003-2670(99)00614-5 · Cited by 181
Self-citationKoziel, J. A., Noah, J., & Pawliszyn, J. (2001) · Environmental Science & Technology · doi:10.1021/es001653i · Cited by 168
Self-citationCarasek, E., & Pawliszyn, J. (2006) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf0613942 · Cited by 166
Self-citationSampling and determination of volatile organic compounds with needle trap devices
Wang, A., Fang, F., & Pawliszyn, J. B. (2005) · Journal of Chromatography A · doi:10.1016/j.chroma.2004.12.064 · Cited by 153
Self-citationRisticevic, S., Carasek, E., & Pawliszyn, J. B. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.04.009 · Cited by 152
Self-citationTrends in solventless sample preparation techniques for environmental analysis
Wardencki, W., Curyło, J., & Namieśnik, J. (2006) · Journal of Biochemical and Biophysical Methods · doi:10.1016/j.jbbm.2006.07.004 · Cited by 145
Lambropoulou, D. A., Konstantinou, I., & Albanis, T. A. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.02.094 · Cited by 144
Ghiasvand, A., Haddadi, S. H., & Pawliszyn, J. B. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.04.088 · Cited by 134
Self-citationBioanalytical applications of solid-phase microextraction
Musteata, F. M., & Pawliszyn, J. B. (2006) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2006.11.003 · Cited by 132
Self-citationWang, Z., Xiao, C., Wu, C., & Han, H. (2000) · Journal of Chromatography A · doi:10.1016/s0021-9673(00)00692-0 · Cited by 129
Analytical Microextraction: Current Status and Future Trends
Pawliszyn, J., & Pedersen-Bjergaard, S. (2006) · Journal of Chromatographic Science · doi:10.1093/chromsci/44.6.291 · Cited by 123
Self-citationAutomation of solid‐phase microextraction
O’Reilly, J. W., Wang, Q., Šetková, L., Hutchinson, J. P., Chen, Y., Lord, H. L., Linton, C. M., & Pawliszyn, J. B. (2005) · Journal of Separation Science · doi:10.1002/jssc.200500244 · Cited by 123
Self-citationPawliszyn, J. B. (2002) · Elsevier eBooks · Cited by 120
Self-citationQin, Z., Bragg, L. M., Ouyang, G., & Pawliszyn, J. B. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.03.063 · Cited by 119
Self-citationDerouiche, A., Driss, M. R., Morizur, J. P., & Taphanel, M. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.10.064 · Cited by 119
In vivo sampling with solid phase microextraction
Musteata, F. M., & Pawliszyn, J. B. (2006) · Journal of Biochemical and Biophysical Methods · doi:10.1016/j.jbbm.2006.07.006 · Cited by 115
Self-citationDevelopment and application of needle trap devices
Eom, I., Tugulea, A.-M., & Pawliszyn, J. B. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.02.090 · Cited by 113
Self-citationStrategies for interfacing solid-phase microextraction with liquid chromatography
Lord, H. L. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.11.073 · Cited by 108
Mullett, W. M., Levsen, K., Lubda, D., & Pawliszyn, J. B. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)00216-9 · Cited by 107
Self-citationSimões, N. G., Cardoso, V. V., Ferreira, E., Benoliel, M. J., & Almeida, C. M. M. (2007) · Chemosphere · doi:10.1016/j.chemosphere.2006.12.057 · Cited by 99
Larroque, V., Desauziers, V., & Mocho, P. (2005) · Journal of Environmental Monitoring · doi:10.1039/b511201j · Cited by 98
Fernández-Álvarez, M. D. M., Llompart, M., Lamas, J. P., Lores, M., García-Jares, C., Cela, R., & Dagnac, T. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.02.080 · Cited by 97
Coupling solid-phase microextraction to liquid chromatography. A review
Zambonin, C. G. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-002-1623-1 · Cited by 91
Kataoka, H., Matsuura, E., & Mitani, K. (2007) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2007.01.023 · Cited by 91
Nongonierma, A. B., Voilley, A. J., Cayot, P., Quéré, J. L., & Springett, M. (2006) · Food Reviews International · doi:10.1080/87559120500379951 · Cited by 90
Automation of solid-phase microextraction on a 96-well plate format
Hutchinson, J. P., Šetková, L., & Pawliszyn, J. B. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.02.117 · Cited by 90
Self-citationJUNIOR, J., & Ré-Poppi, N. (2007) · Talanta · doi:10.1016/j.talanta.2007.02.024 · Cited by 88
Jaber, F., Schummer, C., Chami, J. A., Mirabel, P. J., & Millet, M. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-1115-9 · Cited by 84
Carasek, E., Cudjoe, E., & Pawliszyn, J. B. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.10.092 · Cited by 82
Self-citationDetermination of flavour profile in Iranian fragrant rice samples using cold‐fibre SPME–GC–TOF–MS
Ghiasvand, A., Šetková, L., & Pawliszyn, J. B. (2007) · Flavour and Fragrance Journal · doi:10.1002/ffj.1809 · Cited by 76
Self-citationRocha, C., Pappas, E. A., & Huang, C. (2007) · Environmental Pollution · doi:10.1016/j.envpol.2007.04.029 · Cited by 74
Field Sampling with a Polydimethylsiloxane Thin-Film
Bragg, L. M., Qin, Z., Alaee, M., & Pawliszyn, J. B. (2006) · Journal of Chromatographic Science · doi:10.1093/chromsci/44.6.317 · Cited by 73
Self-citationMusteata, F. M., & Pawliszyn, J. B. (2005) · Journal of Proteome Research · doi:10.1021/pr049768z · Cited by 72
Self-citationOccurrence and Bioavailability of Pyrethroids in a Mixed Land Use Watershed
Budd, R., Bondarenko, S., Haver, D. L., Kabashima, J. N., & Gan, J. (2007) · Journal of Environmental Quality · doi:10.2134/jeq2006.0249 · Cited by 68
Koziel, J. A., Cai, L., Wright, D. W., & Hoff, S. J. (2006) · Journal of Chromatographic Science · doi:10.1093/chromsci/44.7.451 · Cited by 67
Bicchi, C. P., Cordero, C. E. I., & Rubiolo, P. (2004) · Journal of Chromatographic Science · doi:10.1093/chromsci/42.8.402 · Cited by 67
Niri, V. H., Bragg, L. M., & Pawliszyn, J. B. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.03.062 · Cited by 65
Self-citationBudziak, D., Martendal, E., & Carasek, E. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.07.061 · Cited by 61
Development of a syringe pump assisted dynamic headspace sampling technique for needle trap device
Eom, I., Niri, V. H., & Pawliszyn, J. B. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.03.036 · Cited by 59
Self-citationSantana, C. M., Torres-Padrón, M. E., Sosa‐Ferrera, Z., & Santana‐Rodríguez, J. J. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.11.050 · Cited by 58
Development of automated in-tube SPME/LC/MS method for drug analysis
Kataoka, H., Lord, H. L., Yamamoto, S., Narimatsu, S., & Pawliszyn, J. B. (2000) · Journal of Microcolumn Separations · doi:10.1002/1520-667x(2000)12:9 · Cited by 57
Self-citationMusteata, F. M., & Pawliszyn, J. B. (2004) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2004.09.055 · Cited by 57
Self-citationLord, H., Rajabi, M., Safari, S., & Pawliszyn, J. B. (2005) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2005.10.003 · Cited by 54
Self-citationSalgado-Petinal, C., García-Chao, M., Llompart, M., Garcı́a-Jares, C., & Cela, R. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0440-3 · Cited by 51
Herbert, P., Morais, S., Paíga, P., Alves, A., & Santos, L. (2005) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-005-0211-6 · Cited by 48
Vega-Moreno, D., Sosa‐Ferrera, Z., & Santana‐Rodríguez, J. J. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.04.046 · Cited by 47
Lord, H. L., Rajabi, M., Safari, S., & Pawliszyn, J. B. (2007) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2007.01.040 · Cited by 44
Self-citationXie, W., Pawliszyn, J. B., Mullett, W. M., & Matuszewski, B. K. (2007) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2007.08.029 · Cited by 43
Self-citationHolt, R. U. (2001) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)01302-4 · Cited by 41
Rapid analysis of food products by means of high speed gas chromatography
Donato, P., Tranchida, P. Q., Dugo, P., Dugo, G., & Mondello, L. (2007) · Journal of Separation Science · doi:10.1002/jssc.200600407 · Cited by 41
Tang, B., & Isacsson, U. (2008) · Energy & Fuels · doi:10.1021/ef7007166 · Cited by 40
Ferrari, F., Sanusi, A., Millet, M., & Montury, M. (2004) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-004-2587-0 · Cited by 35
Application of solid-phase microextraction to monitoring indoor air quality
Gorlo, D., Zygmunt, B., Dudek, M. K., Jaszek, A., Pilarczyk, M., & Namieśnik, J. (1999) · Fresenius Journal of Analytical Chemistry · doi:10.1007/s002160051273 · Cited by 30
Zuazagoitia, D., Millán, E., & García, R. (2007) · Chromatographia · doi:10.1365/s10337-007-0371-y · Cited by 30
Wei, M., Chang, W.-T., & Jen, J. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0962-8 · Cited by 29
Montes, R., Ramil, M., Rodríguez, I., Rubí, E., & Cela, R. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.04.047 · Cited by 26
Snyder, A. P., Maswadeh, W. M., Tripathi, A., & Dworzański, J. P. (2000) · Field Analytical Chemistry & Technology · doi:10.1002/1520-6521(2000)4:2/3<73::aid-fact2>3.0.co;2-7 · Cited by 26
Zuazagoitia, D., Millán, E., & García-Arrona, R. (2008) · Chromatographia · doi:10.1365/s10337-008-0843-8 · Cited by 24
Sheu, H., Sung, Y., Melwanki, M. B., & Huang, S. (2006) · Journal of Separation Science · doi:10.1002/jssc.200600155 · Cited by 24
Zuliani, T., Lespès, G., Milačić, R., Ščančar, J., & Potin‐Gautier, M. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.07.054 · Cited by 23
Lucio-Gutiérrez, J. R., Salazar‐Cavazos, M. D. L. L., de Torres, N. H. W., & Castro‐Ríos, R. (2008) · Analytical Letters · doi:10.1080/00032710701746758 · Cited by 21
van Hout, M. W. J., Jas, V., Niederländer, H. A. G., de Zeeuw, R. A., & de Jong, G. J. (2002) · The Analyst · doi:10.1039/b110729a · Cited by 15
van Hout, M. W. J., Jas, V., Niederländer, H. A. G., de Zeeuw, R. A., & de Jong, G. J. (2003) · Journal of Separation Science · doi:10.1002/jssc.200301567 · Cited by 14
Lanças, F. M., Olivares, I. R. B., & Egas, P. M. A. (2007) · Journal of Environmental Science and Health Part B · doi:10.1080/03601230701391468 · Cited by 12
Cardinali, F. L., Blount, B. C., Schmidt, R., & Morrow, J. (2008) · Journal of Chromatographic Science · doi:10.1093/chromsci/46.5.381 · Cited by 10
Niri, V. H., & Pawliszyn, J. B. (2007) · The Analyst · doi:10.1039/b617355a · Cited by 8
Self-citation
Cited by
Molecularly imprinted polymers for sample preparation: A review
Turiel, E., & Martín-Esteban, A. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2010.04.019 · Cited by 508
Nondestructive Sampling of Living Systems Using in Vivo Solid-Phase Microextraction
Ouyang, G., Vuckovic, D., & Pawliszyn, J. (2011) · Chemical Reviews · doi:10.1021/cr100203t · Cited by 426
Self-citationSouza-Silva, É. A., Jiang, R., Rodríguez-Lafuente, A., Gionfriddo, E., & Pawliszyn, J. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.04.016 · Cited by 335
Self-citationProtocol for solid-phase microextraction method development
Risticevic, S., Lord, H., Górecki, T., Arthur, C. L., & Pawliszyn, J. (2010) · Nature Protocols · doi:10.1038/nprot.2009.179 · Cited by 331
Self-citationThe role of green extraction techniques in Green Analytical Chemistry
Armenta, S., Garrigues, S., & de la Guardia, M. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.12.011 · Cited by 329
Metadata
- Authors
- Risticevic, S., Niri, V. H., Vuckovic, D., & Pawliszyn, J.
- Venue
- Analytical and Bioanalytical Chemistry
- Published
- 2008-10-04
- Volume
- 393
- Issue
- 3
- Pages
- 781-795
- ISSN
- 1618-2642 (ISSN-L)
- 1618-2650
- OpenAlex
- W1990889920
- Cited by
- 376
- References
- 92
- FWCI
- 31.29
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.