Characterizing ion mobility-mass spectrometry conformation space for the analysis of complex biological samples

Open access
Fenn, Larissa S., Kliman, Michal, Mahsut, Ablatt, Zhao, Sophie R., McLean, John A.·2009·Analytical and Bioanalytical Chemistry

Abstract

AbstractThe conformation space occupied by different classes of biomolecules measured by ion mobility-mass spectrometry (IM-MS) is described for utility in the characterization of complex biological samples. Although the qualitative separation of different classes of biomolecules on the basis of structure or collision cross section is known, there is relatively little quantitative cross-section information available for species apart from peptides. In this report, collision cross sections are measured for a large suite of biologically salient species, including oligonucleotides (n = 96), carbohydrates (n = 192), and lipids (n = 53), which are compared to reported values for peptides (n = 610). In general, signals for each class are highly correlated, and at a given mass, these correlations result in predicted collision cross sections that increase in the order oligonucleotides < carbohydrates < peptides < lipids. The specific correlations are described by logarithmic regressions, which best approximate the theoretical trend of increasing collision cross section as a function of increasing mass. A statistical treatment of the signals observed within each molecular class suggests that the breadth of conformation space occupied by each class increases in the order lipids < oligonucleotides < peptides < carbohydrates. The utility of conformation space analysis in the direct analysis of complex biological samples is described, both in the context of qualitative molecular class identification and in fine structure examination within a class. The latter is demonstrated in IM-MS separations of isobaric oligonucleotides, which are interpreted by molecular dynamics simulations. FigurePotential for performing simultaneous “omics” through the separation of biomolecular classes on the basis of structure and mass using ion mobility-mass spectrometry

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00216-009-2666-3

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 198

Metadata

Authors
Fenn, L. S., Kliman, M., Mahsut, A., Zhao, S. R., & McLean, J. A.
Venue
Analytical and Bioanalytical Chemistry
Published
2009-02-27
Volume
394
Issue
1
Pages
235-244
ISSN
  • 1618-2642 (ISSN-L)
  • 1618-2650
OpenAlex
W2061733910
Cited by
198
References
2
FWCI
5.68
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Characterizing ion mobility-mass spectrometry conformation space for the analysis of complex biological samples. https://app.cochat.ai/papers/10.1007/s00216-009-2666-3
The paper
Fenn, L. S., Kliman, M., Mahsut, A., Zhao, S. R., & McLean, J. A. (2009). Characterizing ion mobility-mass spectrometry conformation space for the analysis of complex biological samples. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-009-2666-3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.