Pesticide extraction from table grapes and plums using ionic liquid based dispersive liquid–liquid microextraction
Abstract
Room temperature ionic liquids (RTILs) have been used as extraction solvents in dispersive liquid-liquid microextraction (DLLME) for the determination of eight multi-class pesticides (i.e. thiophanate-methyl, carbofuran, carbaryl, tebuconazole, iprodione, oxyfluorfen, hexythiazox, and fenazaquin) in table grapes and plums. The developed method involves the combination of DLLME and high-performance liquid chromatography with diode array detection. Samples were first homogenized and extracted with acetonitrile. After evaporation and reconstitution of the extract in water containing sodium chloride, a quick DLLME procedure that used the ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate ([C(6)MIM][PF(6)]) and methanol was developed. The RTIL dissolved in a very small volume of acetonitrile was directed injected in the chromatographic system. The comparison between the calibration curves obtained from standards and from spiked sample extracts (matrix-matched calibration) showed the existence of a strong matrix effect for most of the analyzed pesticides. A recovery study was also developed with five consecutive extractions of the two types of fruits spiked at three concentration levels. Mean recovery values were in the range of 72-100% for table grapes and 66-105% for plum samples (except for thiophanate-methyl and carbofuran, which were 64-75% and 58-66%, respectively). Limits of detection (LODs) were in the range 0.651-5.44 microg/kg for table grapes and 0.902-6.33 mic…
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The first application of IL-DLLME for extraction of pesticides from matrices other than water was by Ravelo-Pérez et al. [38,50] for fruit extracts (bananas, grapes, plums) using HPLC-DAD.
“The first application of IL-DLLME for the extraction of pesticides from matrices other than water was recently developed by Ravelo-Pe ´rez et al . [38,50] for the extraction of fruit extracts (bananas [38], and grapes and plums [50]) using HPLC-DAD for the chromatographic analysis.”
From Dispersive liquid-liquid microextraction for determination of organic analytes (2010) · cites this paper as [50]
For IL-DLLME of pesticides, a relatively small number of works has been published, especially in recent years.
“Regarding IL-DLLME of pesticides, a relatively small number of works has come out, especially in recent years [13-16,32,38,47,50].”
From Dispersive liquid-liquid microextraction for determination of organic analytes (2010) · cites this paper as [50]
In Ravelo-Pérez et al. [50], the method was extended to grapes and plums, with mean recoveries of 64-100% for table grapes and 58-105% for plums, and LODs below EU MRLs.
“The second of these works [50] extended the application of the method for the extraction of the same group of pesticides from grapes and plums. Mean recovery values were 64-100% for table grapes and 58-105% for plums, with LODs very close to the previous ones, also below EU MRLs.”
From Dispersive liquid-liquid microextraction for determination of organic analytes (2010) · cites this paper as [50]
In both Ravelo-Pérez et al. works [38,50], the method was applied to commercial fruit samples, where pesticide residues were found in some but always below MRLs.
“In both works, the method was also applied to the analysis of commercial fruit samples, in which residues of pesticides could be found in some, but always below their MRLs.”
From Dispersive liquid-liquid microextraction for determination of organic analytes (2010) · cites this paper as [50]
IL-DLLME has a drawback of a wide peak at the beginning of the chromatogram corresponding to the IL.
“As can be seen, at the beginning of the chromatogram, there appeared a wide peak, corresponding to the IL - one of the main drawbacks of using IL-DLLME, as already reported [14-19,32,38,47,50,65-67] -although, in this case, it did not interfere at all in the separation.”
From Dispersive liquid-liquid microextraction for determination of organic analytes (2010) · cites this paper as [50]
Cites
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402 · see citing works
Zhou, Q., Bai, H., Xie, G., & Xiao, J. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.02.094 · Cited by 248 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Dispersive liquid-liquid microextraction
Zgoła-Grześkowiak, A., & Grześkowiak, T. (2011) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2011.04.014 · Cited by 476 · see citing works
Rykowska, I., Ziemblińska, J., & Nowak, I. (2018) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2018.03.043 · Cited by 353 · see citing works
Ionic liquids in dispersive liquid-liquid microextraction
Trujillo-Rodríguez, M. J., Rocío-Bautista, P., Pino, V., & Afonso, A. M. (2013) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2013.06.008 · Cited by 276 · see citing works
Dispersive liquid-liquid microextraction for determination of organic analytes
Herrera-Herrera, A. V., Asensio-Ramos, M., Hernández-Borges, J., & Rodríguez-Delgado, M. Á. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2010.03.016 · Cited by 267 · see citing works
Self-citationBeyond dispersive liquid–liquid microextraction
Leong, M.-I., Fuh, M.-R., & Huang, S.-D. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.02.021 · Cited by 241 · see citing works
Ten years of dispersive liquid–liquid microextraction and derived techniques
Campillo, N., Viñas, P., Šandrejová, J., & Andruch, V. (2017) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2016.1224240 · Cited by 102 · see citing works
Ionic liquids in microextraction techniques
Vičkačkaitė, V., & Padarauskas, A. (2012) · Open Chemistry · doi:10.2478/s11532-012-0023-4 · Cited by 84 · see citing works
- Authors
- Ravelo-Pérez, L. M., Hernández-Borges, J., Herrera-Herrera, A. V., & Rodríguez-Delgado, M. Á.
- Venue
- Analytical and Bioanalytical Chemistry
- Published
- 2009-09-25
- Volume
- 395
- Issue
- 7
- Pages
- 2387-2395
- ISSN
- 1618-2642 (ISSN-L)
- 1618-2650
- OpenAlex
- W2089559130
- Cited by
- 64
- References
- 2
- Citations by year
- 2024: 2 · 2022: 1 · 2021: 1 · 2020: 2 · 2019: 3 · 2018: 2 · 2017: 2 · 2016: 4 · 2015: 2 · 2014: 10 · 2013: 7 · 2012: 11
- FWCI
- 9.06
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Analytical and Bioanalytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Life Sciences › Agricultural and Biological Sciences › Food Science › Pesticide Residue Analysis and Safety
- Physical Sciences › Chemical Engineering › Catalysis › Ionic liquids properties and applications
- Keywords
- pesticide residues, table grapes, plum, room temperature ionic liquids, dispersive liquid-liquid microextraction, 1-hexyl-3-methylimidazolium hexafluorophosphate, matrix effects, thiophanate-methyl, carbofuran, carbaryl, tebuconazole, iprodione, oxyfluorfen, hexythiazox, fenazaquin, maximum residue limits, food safety
- MeSH terms
- Chromatography, High Pressure Liquid, Food Analysis, Food Contamination, Chemical Fractionation, Pesticides, Temperature, Molecular Structure, Vitis, Prunus, Ionic Liquids
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review