CoChat

Lab in a syringe: fully automated dispersive liquid–liquid microextraction with integrated spectrophotometric detection

Open access
Maya, Fernando, Horstkotte, Burkhard, Estela, José Manuel, Cerdà, Víctor · 2012 · Analytical and Bioanalytical Chemistry
Cited by 107

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

AbstractA new approach for the integration of various analytical steps inside a syringe (Lab in a Syringe) is presented. Fully automated dispersive liquid–liquid microextraction with integrated spectrophotometric detection is carried out in-syringe using a very simple instrumental setup. The lighter-than-water organic droplets released in the extraction step accumulate at the head of the syringe, where two optical fibers are placed on both sides of the syringe, facing each other and enabling the in situ quantification of the extracted compounds. By this, monitoring of the progressively accumulating droplet in the head of the syringe was further possible. In this first report, the developed instrumental setup has been applied to the determination of the dye rhodamine B in water samples and soft drinks. The main parameters influencing the extraction such as the selection of the extractant and disperser solvents, extractant/disperser and organic/water phase ratios, pH of the aqueous phase, extraction flow rates, and extraction time were investigated. Under the selected conditions, rhodamine B was quantified in a working range of 0.023–2 mg L−1 with a limit of detection of 0.007 mg L−1. Good repeatability values of up to 3.2 % (RSD) were obtained for ten consecutive extractions. The enrichment factor for a 1 mg L−1 rhodamine B standard was 23, and up to 51 extractions were accomplished in 1 h. FigureThe dispersive liquid-liquid microextraction technique is fully automated based on in-syringe extraction followed by in-situ spectrophotometric detection

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00216-012-6159-4

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 107

Metadata

Authors
Maya, F., Horstkotte, B., Estela, J. M., & Cerdà, V.
Venue
Analytical and Bioanalytical Chemistry
Published
2012-06-15
Volume
404
Issue
3
Pages
909-917
ISSN
  • 1618-2642 (ISSN-L)
  • 1618-2650
OpenAlex
W2051740807
Cited by
107
References
7
FWCI
8.45
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Lab in a syringe: fully automated dispersive liquid–liquid microextraction with integrated spectrophotometric detection. https://app.cochat.ai/papers/10.1007/s00216-012-6159-4
The paper
Maya, F., Horstkotte, B., Estela, J. M., & Cerdà, V. (2012). Lab in a syringe: fully automated dispersive liquid–liquid microextraction with integrated spectrophotometric detection. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-012-6159-4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.