CoChat

New sample preparation method based on task-specific ionic liquids for extraction and determination of copper in urine and wastewater

Trtić-Petrović, Tatjana, Dimitrijević, Aleksandra, Zdolšek, Nikola, Đorđević, Jelena, Tot, Aleksandar, Vraneš, Milan, Gadžurić, Slobodan · 2018 · Analytical and Bioanalytical Chemistry

The DOI matches its Crossref record; 33 of the 34 references it cites were found in a registry or an index.

Abstract

In this study, four hydrophilic ionic liquids (ILs) containing 1-alkyl-3-methylimidazolim cation and either salicylate or chloride anions were synthetized and studied as new task-specific ionic liquids (TSILs) suitable for aqueous biphasic system (ABS) formation and selective one-step extraction of copper(II). TSILs are designed so that the anion is responsible for forming the complex with metal(II) and preventing hydrolysis of metal cations at very strong alkaline pH, whereas the cation is responsible for selective extraction of metal(II)-salicylate complexes. It was found that 1-butyl-3-methylimidazolium salicylate could be used for selective extraction of Cu(II) in the presence of Zn(II), Cd(II), and Pb(II) at very alkaline solution without metal hydroxide formation. It was assumed that formation of metal(II)-salicylate complexes prevents the hydrolysis of the metal ions in alkaline solutions. The determined stability constants for Cu(II)-salicylate complexes, where salicylate was derived from different ionic liquids, indicated that there was no significant influence of the cation of the ionic liquid on the stability of the complexes. The ABS based on 1-butyl-3-methylimidazolium salicylate has been applied as the sample preparation step prior to voltammetric determination of Cu(II). The effect of volume of aqueous sample and IL and extraction time were investigated and optimum extraction conditions were determined. The obtained detection limits were 8 ng dm -3 . The optimi…

Overview

Integrity signals

Registry

Crossref · 10.1007/s00216-017-0705-z

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 33 references

Cited by

See all 22

Metadata

Authors
Trtić-Petrović, T., Dimitrijević, A., Zdolšek, N., Đorđević, J., Tot, A., Vraneš, M., & Gadžurić, S.
Affiliations
  • University of Belgrade (RS)
  • University of Novi Sad (RS)
Venue
Analytical and Bioanalytical Chemistry
Published
2017-11-02
Volume
410
Issue
1
Pages
155-166
ISSN
  • 1618-2642 (ISSN-L)
  • 1618-2650
OpenAlex
W2766935846
Cited by
22
References
34
Citations by year
2026: 2 · 2025: 1 · 2024: 1 · 2023: 3 · 2022: 3 · 2021: 4 · 2020: 1 · 2019: 6 · 2018: 1
FWCI
1.53
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical and Bioanalytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
  • VinaR (Institute of Nuclear Sciences "Vinča") (submittedVersion)
Funders
Ministry of Education, Science and Technological Development of Serbia under project contracts (III 45006 and ON 172012)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Physical Sciences › Chemical Engineering › Filtration and Separation › Chemical and Physical Properties in Aqueous Solutions
  • Physical Sciences › Chemistry › Physical and Theoretical Chemistry › Ionic liquids properties and applications
Keywords
task-specific ionic liquids, copper(II) extraction, aqueous two-phase systems, complex stability constants, voltammetric determination, selective metal recovery
MeSH terms
Anions, Cations, Copper, Chemical Fractionation, Humans, Imidazoles, Salicylates, Water Pollutants, Chemical, Phase Transition, Ionic Liquids, Electrochemical Techniques, Coordination Complexes, Limit of Detection, Wastewater

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: New sample preparation method based on task-specific ionic liquids for extraction and determination of copper in urine and wastewater. https://app.cochat.ai/papers/10.1007/s00216-017-0705-z
The paper
Trtić-Petrović, T., Dimitrijević, A., Zdolšek, N., Đorđević, J., Tot, A., Vraneš, M., & Gadžurić, S. (2018). New sample preparation method based on task-specific ionic liquids for extraction and determination of copper in urine and wastewater. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-017-0705-z

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.