Cited by 27Thyroid Disorders and TreatmentsAnalytical Methods in PharmaceuticalsAnalytical chemistry methods development

A combined LC-MS/MS and LC-MS3 multi-method for the quantification of iodothyronines in human blood serum

Richards, Keith H., Monk, Ray, Renko, Kostja, Rathmann, Daniel, Rijntjes, Eddy, Köhrle, Josef·2019·Analytical and Bioanalytical Chemistry

Abstract

We report here a novel approach for the extraction and analysis of thyroid hormones (TH) and their metabolites (THM) from human serum samples. Our method features a compact, 96-well micro-titre plate-based pre-analytic extraction/clean-up workflow combined with an isotope dilution LC-MS/MS-MS 3 analytical method. In particular, these features make possible the detection of iodothyronines at their endogenous concentrations in serum differing by a factor of ca. 10 4 , with potential to semi-automate the pre-analytics. The method was validated by the assessment of linearity, lower limits of quantification and detection (LLOQ and LLOD respectively), intra- and inter-day accuracy, precision, process efficiency (PE), matrix effect (ME) and relative recovery (RE). Calibration curves were linear in the concentration range in sample matrix from 0.1-250 nM for T 3 , rT 3 , T 4 and 3-T 1 AM and from 0.005-1 nM for 3,5-T 2 and 3,3'-T 2 . Using a 200-μL sample volume, the analyte dependant LLOQ were in the range 0.005 (3,5-T 2 ) to 0.25 (T 4 ) nM and LLOD were between 0.002 (3,5-T 2 ) and 0.052 nM (T 4 ). We applied the LC-MS/MS-MS 3 method to the analysis of a cross section of patients with disorders of the thyroid hormone axis. T 4 , T 3 and rT 3 concentrations (± standard deviation) were 120 ± 18, 1.9 ± 0.4 and 0.45 ± 0.09 nM respectively. 3,3'-T 2 concentrations (± standard deviation) were 0.079 ± 0.022 nM; 3,5-T 2 concentrations were below the LLOQ and/or LLOD in all but a single sam…

Integrity signals

Registry

Crossref · 10.1007/s00216-019-01941-9

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cited by

Sorted by citations

Authors
Richards, K. H., Monk, R., Renko, K., Rathmann, D., Rijntjes, E., & Köhrle, J.
Affiliations
  • Charité – Universitätsmedizin Berlin (DE)
  • Menarini Group (Germany) (DE)
Corresponding author
Köhrle, Josef
Venue
Analytical and Bioanalytical Chemistry
Published
2019-06-15
Volume
411
Issue
21
Pages
5605-5616
ISSN
  • 1618-2642 (ISSN-L)
  • 1618-2650
OpenAlex
W2950995063
Cited by
27
References
0
Citations by year
2026: 2 · 2025: 2 · 2024: 2 · 2023: 1 · 2022: 7 · 2021: 3 · 2020: 9 · 2019: 1
FWCI
2.64
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical and Bioanalytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Funders
Deutsche Forschungsgemeinschaft (KO922-17/1-2)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Thyroid Disorders and Treatments
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
Keywords
iodothyronines, thyroid hormones, thyroid hormone metabolites, human serum, isotope dilution, reverse T3, triiodothyronine, thyroxine, thyroid hormone metabolism
MeSH terms
Calibration, Chromatography, Liquid, Humans, Reference Standards, Thyronines, Reproducibility of Results, Tandem Mass Spectrometry, Limit of Detection

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review