Abstract

A non-ionic hydrophobic natural deep eutectic solvent (HNADES) based on thymol and menthol was proposed for the liquid-liquid microextraction of fourteen phthalates and one adipate from environmental water samples. Separation, identification, and quantification were achieved by ultra-high-performance liquid chromatography coupled to tandem mass spectrometry. The main factors affecting the extraction efficiency were thoroughly studied. Sample pH of 8 and 100 μL of thymol:menthol at molar ratio 2:1 were selected as the best conditions, while ionic strength and type of dispersant solvent were not relevant for the extraction of the target compounds. The whole methodology was validated for treated wastewater, runoff, and pond water matrices, using di-n-butyl phthalate-3,4,5,6-d4 and dihexyl phthalate-3,4,5,6-d4 as surrogates. Recovery ranged from 70 to 127% with relative standard deviation values lower than 14%. Limits of quantification of the method were in the range 0.042–0.425 μg/L for treated wastewater, 0.015–0.386 μg/L for runoff, and 0.013–0.376 μg/L for pond water. The methodology was applied for the analysis of real treated wastewater, runoff, and pond water samples from different places of Tenerife and Gran Canaria (Canary Islands) finding the presence of diethyl phthalate, diallyl phthalate, dipropyl phthalate, benzylbutyl phthalate, di-n-butyl phthalate, bis-(2-n-butoxyethyl) phthalate, di-n-pentyl phthalate, dicyclohexyl phthalate, and bis-(2-ethylhexyl) phthalate at concentrations between 105.2 and 3414 ng/L.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00216-021-03166-1

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 50

Metadata

Authors
Santana-Mayor, Á., Socas-Rodríguez, B., Rodríguez-Ramos, R., Herrera-Herrera, A. V., & Rodríguez-Delgado, M. Á.
Venue
Analytical and Bioanalytical Chemistry
Published
2021-02-03
Volume
413
Issue
7
Pages
1967-1981
ISSN
  • 1618-2642 (ISSN-L)
  • 1618-2650
OpenAlex
W3127286491
Cited by
50
References
6
FWCI
3.65
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quality assessment of environmental water by a simple and fast non-ionic hydrophobic natural deep eutectic solvent-based extraction procedure combined with liquid chromatography tandem mass spectrometry for the determination of plastic migrants. https://app.cochat.ai/papers/10.1007/s00216-021-03166-1
The paper
Santana-Mayor, Á., Socas-Rodríguez, B., Rodríguez-Ramos, R., Herrera-Herrera, A. V., & Rodríguez-Delgado, M. Á. (2021). Quality assessment of environmental water by a simple and fast non-ionic hydrophobic natural deep eutectic solvent-based extraction procedure combined with liquid chromatography tandem mass spectrometry for the determination of plastic migrants. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-021-03166-1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.