Performing a set of isometric muscular contractions to varied amplitudes with instructions to generate force most rapidly reveals a strong linear relationship between peak forces (PF) achieved and corresponding peak rates of force development (RFD). The slope of this relationship, termed the RFD scaling factor (RFD-SF), quantifies the extent to which RFD scales with contraction amplitude. Such scaling allows relative invariance in the time required to reach PF regardless of contraction size. Considering the increasing use of this relationship to study quickness and consequences of slowness in older adults and movement disorders, our purpose was to further develop the protocol to measure RFD-SF. Fifteen adults (19-28 years) performed 125 rapid isometric contractions to a variety of force levels in elbow extensors, index finger abductors, and knee extensors, on 2 days. Data were used to determine (1) how the number of pulses affects computation of the RFD-SF, (2) day-to-day reliability of the RFD-SF, and (3) the nature of RFD-SF differences between diverse muscle groups. While sensitive to the number of pulses used in its computation (P 50 pulses (ICC>.7) and more so with 100-125 pulses (ICC=.8-.92). Despite differences in size and function across muscles, RFD-SF was generally similar (i.e., only 8.5% greater in elbow extensors than in index finger abductors and knee extensors; P=.049). Results support this protocol as a reliable means to assess how RFD scales with PF in rapid…

Overview

Integrity signals

Registry

Crossref · 10.1007/s00221-011-2735-7

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 38 references

Research works printed but not linked: 1

  1. Safrit MJ (1976) Reliability theory. AAHPER Publications, Washington

Cited by

See all 81

Metadata

Authors
Bellumori, M., Jaric, S., & Knight, C. A.
Affiliations
University of Delaware (US)
Corresponding author
Knight, Christopher A.
Venue
Experimental Brain Research
Published
2011-06-09
Volume
212
Issue
3
Pages
359-369
ISSN
  • 0014-4819 (ISSN-L)
  • 1432-1106
OpenAlex
W2068513504
Cited by
65
References
39
Citations by year
2026: 4 · 2025: 3 · 2024: 6 · 2023: 4 · 2022: 6 · 2021: 3 · 2020: 9 · 2019: 3 · 2018: 5 · 2017: 5 · 2016: 5 · 2015: 1 · 2014: 3 · 2013: 3 · 2012: 3
FWCI
3.39
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • Experimental Brain Research (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Institute of Arthritis and Musculoskeletal and Skin Diseases (R21AR060659)
Topics
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
Keywords
rate of force development, isometric contraction, peak force, day-to-day reliability, elbow extensors, knee extensors, quickness, movement disorders, older adults
MeSH terms
Adult, Elbow, Electromyography, Female, Humans, Isometric Contraction, Knee, Male, Sensitivity and Specificity, Reproducibility of Results, Muscle, Skeletal

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The rate of force development scaling factor (RFD-SF): protocol, reliability, and muscle comparisons. https://app.cochat.ai/papers/10.1007/s00221-011-2735-7
The paper
Bellumori, M., Jaric, S., & Knight, C. A. (2011). The rate of force development scaling factor (RFD-SF): protocol, reliability, and muscle comparisons. Experimental Brain Research. https://doi.org/10.1007/s00221-011-2735-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.