The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Disposable bioreactors: the current state-of-the-art and recommended applications in biotechnology
Open accessAbstract
Disposable bioreactors have increasingly been incorporated into preclinical, clinical, and production-scale biotechnological facilities over the last few years. Driven by market needs, and, in particular, by the developers and manufacturers of drugs, vaccines, and further biologicals, there has been a trend toward the use of disposable seed bioreactors as well as production bioreactors. Numerous studies documenting their advantages in use have contributed to further new developments and have resulted in the availability of a multitude of disposable bioreactor types which differ in power input, design, instrumentation, and scale of the cultivation container. In this review, the term “disposable bioreactor” is defined, the benefits and constraints of disposable bioreactors are discussed, and critical phases and milestones in the development of disposable bioreactors are summarized. An overview of the disposable bioreactors that are currently commercially available is provided, and the domination of wave-mixed, orbitally shaken, and, in particular, stirred disposable bioreactors in animal cell-derived productions at cubic meter scale is reported. The growth of this type of reactor system is attributed to the recent availability of stirred disposable benchtop systems such as the Mobius CellReady 3 L Bioreactor. Analysis of the data from computational fluid dynamic simulation studies and first cultivation runs confirms that this novel bioreactor system is a viable alternative to traditional cell culture bioreactors at benchtop scale.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cell Culture on Artificial Capillaries: an Approach to Tissue Growth In Vitro
Knazek, R. A., Gullino, P. M., Kohler, P. O., & Dedrick, R. L. (1972) · Science · doi:10.1126/science.178.4056.65 · Cited by 424
Disposable bioreactor for cell culture using wave-induced agitation
Singh, V. (1999) · Cytotechnology · doi:10.1023/a:1008025016272 · Cited by 303
Cell Culture Technology for Pharmaceutical and Cell-Based Therapies
(2005) · CRC Press eBooks · doi:10.1201/9780849351068 · Cited by 291
Büchs, J., Maier, U., Milbradt, C., & Zoels, B. (2000) · Biotechnology and Bioengineering · doi:10.1002/(sici)1097-0290(20000620)68:6<589::aid-bit1>3.0.co;2-j · Cited by 207
Disposable Bioreactor for Cell Culture Using Wave-Induced Agitation
Singh, V. (2006) · New Developments and New Applications in Animal Cell Technology · doi:10.1007/0-306-46860-3_74 · Cited by 175
Orbital shaker technology for the cultivation of mammalian cells in suspension
Muller, N., Girard, P., Hacker, D. L., Jordan, M., & Wurm, F. M. (2005) · Biotechnology and Bioengineering · doi:10.1002/bit.20358 · Cited by 175
Advances in understanding and modeling the gas–liquid mass transfer in shake flasks
Maier, U., Losen, M., & Büchs, J. (2004) · Biochemical Engineering Journal · doi:10.1016/s1369-703x(03)00174-8 · Cited by 161
Genzel, Y., Behrendt, I., König, S., Sann, H., & Reichl, U. (2003) · Vaccine · doi:10.1016/s0264-410x(03)00834-x · Cited by 159
Jesus, M. J. D., Girard, P., Bourgeois, M., Baumgartner, G., Jacko, B., Amstutz, H., & Wurm, F. M. (2003) · Biochemical Engineering Journal · doi:10.1016/s1369-703x(03)00180-3 · Cited by 154
Simple bioreactors for mass propagation of plants
Ziv, M. (2005) · Springer eBooks · doi:10.1007/1-4020-3200-5_5 · Cited by 144
Cited by
Wilson, S. A., & Roberts, S. C. (2012) · Plant Biotechnology Journal · doi:10.1111/j.1467-7652.2011.00664.x · Cited by 358
Progress and challenges in large-scale expansion of human pluripotent stem cells
Kropp, C., Massai, D., & Zweigerdt, R. (2017) · Process Biochemistry · doi:10.1016/j.procbio.2016.09.032 · Cited by 167
Disposable Flat Panel Airlift Photobioreactors
Bergmann, P., Ripplinger, P., Beyer, L., & Trösch, W. (2013) · Chemie Ingenieur Technik · doi:10.1002/cite.201200132 · Cited by 41
Metadata
- Authors
- Eibl, R., Kaiser, S., Lombriser, R., & Eibl, D.
- Venue
- Applied Microbiology and Biotechnology
- Published
- 2010-01-22
- Volume
- 86
- Issue
- 1
- Pages
- 41-49
- ISSN
- 0175-7598 (ISSN-L)
- 1432-0614
- OpenAlex
- W2015481043
- Cited by
- 260
- References
- 41
- FWCI
- 15.65
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Disposable bioreactors: the current state-of-the-art and recommended applications in biotechnology. https://app.cochat.ai/papers/10.1007/s00253-009-2422-9
- The paper
- Eibl, R., Kaiser, S., Lombriser, R., & Eibl, D. (2010). Disposable bioreactors: the current state-of-the-art and recommended applications in biotechnology. Applied Microbiology and Biotechnology. https://doi.org/10.1007/s00253-009-2422-9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.