The reliability of plain radiography in experimental fracture healing
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Objective To investigate the reliability of radiographs in the evaluation of healing of closed fractures.Design A closed midshaft tibial fracture was created in 40 goats and stabilized with an external fixator. The animals were assigned to four groups: no injection, injection of 1 mg osteogenic protein-1 (OP-1), 1 mg OP-1 with collagenous carrier, or carrier alone. Radiographs were performed weekly until the animals were killed after 2 and 4 weeks. Healing was evaluated using radiographs, biomechanical testing, and histological examination. All radiographs were examined by two independent observers. Interobserver agreement was calculated and radiographic scores were compared with mechanical and histological scores using regression analysis.Results Regression analysis showed poor correlation between radiographic scores and biomechanical and histological data. Correlation coefficients varied between 0.39 and 0.63. Good agreement between the observers was seen in only three parameters: visibility of the fracture line, weightbearing ability, and a combined healing parameter.Conclusion Plain radiography provides poor parameters for monitoring the fracture healing process.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In addition to radiation exposure, X-ray-based imaging has the disadvantage of showing healing progress with a time lag, as it reflects only the progress in calcification and not the actual improvements in stiffness (145).”
From Methods to accelerate fracture healing – a narrative review from a clinical perspective (2024) · cites this paper as [145]
Citations
Cites
Accuracy of Radiologic Assessment of Tibia1 Shaft Fracture Union in Humans
HAMMER, R. R. R., Hammerby, S., & Lindholm, B. (1985) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198510000-00033 · Cited by 194
Accuracy of radiologic assessment of tibial shaft fracture union in humans.
HAMMER, R. R. R., Hammerby, S., & Lindholm, B. (1985) · PubMed · Cited by 149
Bone Grafts and Bone Substitutes
Habal, M. B., & Reddi, A. H. (1994) · Journal of Craniofacial Surgery · doi:10.1097/00001665-199402000-00017 · Cited by 122
OSTEOINDUCTIVE GROWTH FACTORS IN PRECLINICAL FRACTURE AND LONG BONE DEFECTS MODELS
Bostrom, M. P., Saleh, K. J., & Einhorn, T. A. (1999) · Orthopedic Clinics of North America · doi:10.1016/s0030-5898(05)70117-6 · Cited by 119
Quantification of fracture healing with three-dimensional computed tomography
den Boer, F. C., Bramer, J. A. M., Patka, P., Bakker, F. C., Barentsen, R. H., Feilzer, A. J., Klerk, E. S. M. D. L., & Haarman, H. J. T. M. (1998) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s004020050263 · Cited by 93
Self-citationMarkel, M. D., & Chao, E. Y. S. (1993) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199308000-00006 · Cited by 79
The Clinicianʼs Ability to Evaluate the Strength of Healing Fractures from Plain Radiographs
Panjabi, M. M., Lindsey, R. W., Walter, S. D., & White, A. A. (1989) · Journal of Orthopaedic Trauma · doi:10.1097/00005131-198903010-00006 · Cited by 66
Quantification of bone healing: Comparison of QCT, SPA, MRI, and DEXA in dog osteotomies
Markel, M. D., Wikenheiser, M. A., Morin, R. L., Lewallen, D. G., & Chao, E. Y. S. (1990) · Acta Orthopaedica Scandinavica · doi:10.3109/17453679008993569 · Cited by 65
Aro, H. T., Wippermann, B. W., Hodgson, S. F., Wahner, H. W., Lewallen, D. G., & Chao, E. Y. S. (1989) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-198971070-00008 · Cited by 65
X-Ray Diagnosis of Healing Fractures in Rabbits
NICHOLLS, P. J., BERG, E., BLIVEN, F. E., & KLING, J. M. (1979) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-197907000-00037 · Cited by 64
Cited by
Cyclo-Oxygenase 2 Function Is Essential for Bone Fracture Healing
Simon, A. M., Manigrasso, M. B., & O'Connor, J. P. (2002) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2002.17.6.963 · Cited by 530
Current Options for Determining Fracture Union
Morshed, S. (2014) · Advances in Medicine · doi:10.1155/2014/708574 · Cited by 214
Termaat, M. F. (2005) · The Journal of Bone and Joint Surgery (American) · doi:10.2106/jbjs.d.02585 · Cited by 209
Self-citationBhandari, M., Fong, K., Sprague, S., Williams, D., & Petrisor, B. (2012) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.k.01344 · Cited by 179
Outcome Assessment in Clinical Trials of Fracture-Healing
Morshed, S., Corrales, L., Genant, H., & Miclau, T. (2008) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.g.01556 · Cited by 170
High-resolution in vivo imaging of bone and joints: a window to microarchitecture
Geusens, P., Chapurlat, R. D., Schett, G. A., Ghasemzadeh, A., Seeman, E., de Jong, J. J. A., & van den Bergh, J. P. (2014) · Nature Reviews Rheumatology · doi:10.1038/nrrheum.2014.23 · Cited by 152
Fracture healing: A review of clinical, imaging and laboratory diagnostic options
Cunningham, B. P., Brazina, S., Morshed, S., & Miclau, T. (2017) · Injury · doi:10.1016/j.injury.2017.04.020 · Cited by 154
Koewler, N. J., Freeman, K. T., Buus, R. J., Herrera, M. B., Jimenez-Andrade, J. M., Ghilardi, J. R., Peters, C. M., Sullivan, L. J., Kuskowski, M. A., Lewis, J. L., et al. (2007) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.070711 · Cited by 113
Reliability of radiographs in defining union of internally fixed fractures
Davis, B. J., Roberts, P. J., Moorcroft, C. I., Brown, M. F., Thomas, P. B. M., & Wade, R. (2003) · Injury · doi:10.1016/s0020-1383(03)00262-6 · Cited by 107
An Ultrasound Wearable System for the Monitoring and Acceleration of Fracture Healing in Long Bones
Protopappas, V. C., Baga, D., Fotiadis, D. I., Likas, A. C., Papachristos, A. A., & Malizos, Κ. Ν. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851507 · Cited by 107
Seeherman, H. J., Li, R., & Wozney, J. M. (2003) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-200300003-00016 · Cited by 111
Chiavaras, M. M., Bains, S., Choudur, H. N., Parasu, N., Jacobson, J. A., Ayeni, O. R., Petrisor, B. A., Chakravertty, R., Sprague, S., & Bhandari, M. (2013) · Skeletal Radiology · doi:10.1007/s00256-013-1605-8 · Cited by 95
Fracture Healing Assessment Comparing Stiffness Measurements using Radiographs
McClelland, D., Thomas, P. B. M., Bancroft, G. A., & Moorcroft, C. I. (2006) · Clinical Orthopaedics and Related Research · doi:10.1097/blo.0b013e31802f80a8 · Cited by 93
Ultrasonic monitoring of bone fracture healing
Protopappas, V. C., Vavva, M. G., Fotiadis, D. I., & Malizos, Κ. Ν. (2008) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2008.787 · Cited by 84
Quantification of Fracture Healing from Radiographs Using the Maximum Callus Index
Eastaugh-Waring, S. J., Joslin, C. C., Hardy, J. R. W., & Cunningham, J. L. (2009) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-009-0775-0 · Cited by 78
den Boer, F. C., Bramer, J. A. M., Blokhuis, T. J., Soest, E. J. V., Jenner, J., Patka, P., Bakker, F. C., Burger, E. H., & Haarman, H. J. T. M. (2002) · Bone · doi:10.1016/s8756-3282(02)00816-5 · Cited by 73
Self-citationHuang, A. J., Chang, C. Y., Thomas, B. J., MacMahon, P. J., & Palmer, W. E. (2015) · Skeletal Radiology · doi:10.1007/s00256-015-2105-9 · Cited by 63
Validation of the use of radiographic fracture-healing scores in a small animal model
Tawonsawatruk, T., Hamilton, D. F., & Simpson, H. (2014) · Journal of Orthopaedic Research® · doi:10.1002/jor.22665 · Cited by 67
Comparison of Fracture Healing Among Different Inbred Mouse Strains
Manigrasso, M. B., & O’Connor, J. P. (2008) · Calcified Tissue International · doi:10.1007/s00223-008-9144-3 · Cited by 58
In vivo measurement of bending stiffness in fracture healing
HENTE, R., Cordey, J., & Perren, S. M. (2003) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-2-8 · Cited by 57
Do bisphosphonates inhibit direct fracture healing? A laboratory investigation using an animal model
Savaridas, T., Wallace, R. J., Salter, D. M., & Simpson, H. (2013) · The Bone & Joint Journal · doi:10.1302/0301-620x.95b9.31562 · Cited by 61
MDCT Versus Digital Radiography in the Evaluation of Bone Healing in Orthopedic Patients
Krestan, C. R., Noske, H., Vasilevska, V., Weber, M., Schueller, G., Imhof, H., & Czerny, C. (2006) · American Journal of Roentgenology · doi:10.2214/ajr.05.0478 · Cited by 52
Digital Tomosynthesis to Evaluate Fracture Healing: Prospective Comparison With Radiography and CT
Ha, A. S., Lee, A. Y., Hippe, D. S., Chou, S.-H. S., & Chew, F. S. (2015) · American Journal of Roentgenology · doi:10.2214/ajr.14.13833 · Cited by 52
Gait analysis to monitor fracture healing of the lower leg
Warmerdam, E., Orth, M., Pohlemann, T., & Ganse, B. (2023) · Bioengineering · doi:10.3390/bioengineering10020255 · Cited by 47
“quent radiographs that come at the cost of radiation exposure and reflect fracture healing with a time lag, as fracture mineralization occurs later than the increases in stiffness [18].”
BackgroundReliability of the Radiographic Union Score for Tibial Fractures
Cekic, E., Alici, E., & Yesil, M. (2020) · Acta Orthopaedica et Traumatologica Turcica · doi:10.3944/aott.2014.14.0026 · Cited by 48
Litrenta, J. M., Tornetta, P., Ricci, W. M., SANDERS, R. W., O’Toole, R. V., Nascone, J. W., Faber, H., & Wilson, D. (2017) · Journal of Orthopaedic Trauma · doi:10.1097/bot.0000000000000753 · Cited by 43
Concepts and clinical aspects of active implants for the treatment of bone fractures
Ganse, B., Orth, M., Roland, M., Diebels, S., Motzki, P., Seelecke, S., Kirsch, S.-M., Welsch, F., Andres, A., Wickert, K., et al. (2022) · Acta Biomaterialia · doi:10.1016/j.actbio.2022.05.001 · Cited by 37
Effect of Aspirin on Bone Healing in a Rabbit Ulnar Osteotomy Model
Lack, W. D., Fredericks, D. C., Petersen, E. B., Donovan, M. D., George, M., Nepola, J. V., Smucker, J. D., & Femino, J. E. (2013) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.l.00462 · Cited by 39
A Practical Guide to Research: Design, Execution, and Publication
Karlsson, J., Marx, R. G., Nakamura, N., & Bhandari, M. (2011) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2011.02.001 · Cited by 42
Ultrasound Monitoring of Fracture Healing: Is This the End of Radiography in Fracture Follow-ups?
Chachan, S., Tudu, B., & Sahu, B. (2014) · Journal of Orthopaedic Trauma · doi:10.1097/bot.0000000000000207 · Cited by 35
Suzuki, T., Matsuura, Y., Yamazaki, T., Akasaka, T., Ozone, E., Matsuyama, Y., Mukai, M., Ohara, T., Wakita, H., Taniguchi, S., et al. (2019) · Bone · doi:10.1016/j.bone.2019.115212 · Cited by 36
Methods to accelerate fracture healing – a narrative review from a clinical perspective
Ganse, B. (2024) · Frontiers in Immunology · doi:10.3389/fimmu.2024.1384783 · Cited by 33
Implantable strain sensor to monitor fracture healing with standard radiography
Pelham, H., Benza, D., Millhouse, P. W., Carrington, N., Arifuzzaman, M., Behrend, C. J., Anker, J. N., & DesJardins, J. D. (2017) · Scientific Reports · doi:10.1038/s41598-017-01009-7 · Cited by 33
Cone Beam CT in Assessment of Tibial Bone Defect Healing: An Animal Study
Kröpil, P., Hakimi, A. R., Jungbluth, P., Riegger, C., Rubbert, C., Miese, F. R., Lanzman, R. S., Wild, M., Schek, A., Scherer, A., et al. (2011) · Academic Radiology · doi:10.1016/j.acra.2011.10.022 · Cited by 31
Firoozabadi, R., Morshed, S., Engelke, K., Prevrhal, S., Fierlinger, A. L., Miclau, T., & Genant, H. K. (2008) · Journal of Orthopaedic Trauma · doi:10.1097/bot.0b013e31815ea2a4 · Cited by 32
Abu-Serriah, M., Kontaxis, A., Ayoub, A. F., Harrison, J., Odell, E. W., & Barbenel, J. C. (2004) · International Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.ijom.2004.09.008 · Cited by 27
CT-Verified Union Rate Following Arthrodesis of Ankle, Hindfoot, or Midfoot: A Systematic Review
Leslie, M. D., Schindler, C., Rooke, G., & Dodd, A. E. (2023) · Foot & Ankle International · doi:10.1177/10711007231171087 · Cited by 26
Choi, S. Y., Hur, W., Kim, B. K., Shasteen, C., Kim, M. H., Choi, L. M., Lee, S. H., Park, C. G., Park, M., Min, H. S., et al. (2014) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.33235 · Cited by 25
Towards a Non-Invasive Technique for Healing Assessment of Internally Fixated Femur
Chiu, W. K., Vien, B. S., Russ, M. K., & Fitzgerald, M. (2019) · Sensors · doi:10.3390/s19040857 · Cited by 21
Warmerdam, E., Wolff, C. G., Orth, M., Pohlemann, T., & Ganse, B. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1355254 · Cited by 20
Lin, M. C., Yang, F. F., Herfat, S. T., Bahney, C. S., Marmor, M. T., & Maharbiz, M. M. (2017) · Journal of Orthopaedic Research® · doi:10.1002/jor.23570 · Cited by 22
Trafton, P. G. (2009) · Elsevier eBooks · doi:10.1016/b978-1-4160-2220-6.10058-1 · Cited by 24
Vien, B. S., Chiu, W. K., Russ, M. K., & Fitzgerald, M. (2022) · Sensors · doi:10.3390/s22020670 · Cited by 16
Wolynski, J. G., Ilić, M. M., Notaroš, B. M., Labus, K. M., Puttlitz, C. M., & McGilvray, K. C. (2021) · IEEE Access · doi:10.1109/access.2021.3137718 · Cited by 15
North, K., Simpson, G. M., Geiger, W., Cizik, A. M., Rothberg, D. L., & Hitchcock, R. W. (2024) · Sensors · doi:10.3390/s24165321 · Cited by 17
Clinical experiences with ultrasonometric measurement of fracture healing
Glinkowski, W., & Górecki, A. (2006) · Technology and Health Care · doi:10.3233/thc-2006-144-514 · Cited by 15
Rajamanthrilage, A. C., Arifuzzaman, M., Millhouse, P. W., Pace, T. B., Behrend, C. J., DesJardins, J. D., & Anker, J. N. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3092291 · Cited by 14
Mazdeh, D. Z., Mirshokraei, P., Emami, M., Mirshahi, A., & Karimi, I. (2017) · Research in Veterinary Science · doi:10.1016/j.rvsc.2017.12.024 · Cited by 12
Clinical Aspects of Fracture Healing: An Overview
Liu, J. X., Buza, J. A., & Leucht, P. (2015) · Clinical Reviews in Bone and Mineral Metabolism · doi:10.1007/s12018-015-9196-7 · Cited by 11
Wolynski, J. G., Labus, K. M., Easley, J. T., Notaroš, B. M., Ilić, M. M., Puttlitz, C. M., & McGilvray, K. C. (2021) · Annals of Translational Medicine · doi:10.21037/atm-21-1853 · Cited by 11
Quantitative assessment of bone defect healing by multidetector CT in a pig model
Riegger, C., Kröpil, P., Jungbluth, P., Lanzman, R. S., Miese, F. R., Hakimi, A. R., Hakimi, M. Y., Wild, M., Antoch, G., & Scherer, A. (2011) · Skeletal Radiology · doi:10.1007/s00256-011-1203-6 · Cited by 11
Ghavami, S., Gregory, A., Webb, J. M., Bayat, M., Denis, M. F., Kumar, V., Milbrand, T. A., Larson, A. N., Fatemi, M., & Alizad, A. (2019) · Sensors · doi:10.3390/s19040955 · Cited by 11
Direct electromagnetic coupling to determine diagnostic bone fracture stiffness
Wolynski, J. G., Ilić, M. M., Labus, K. M., Notaroš, B. M., Puttlitz, C. M., & McGilvray, K. C. (2022) · Annals of Translational Medicine · doi:10.21037/atm-21-5315 · Cited by 10
Najafzadeh, A., Wong, L., Gunawardena, D. S., Tran, T., Fu, J. W., Chen, B. K., Cheng, X., & Tam, H. (2022) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2022.113930 · Cited by 10
The development of a novel model of direct fracture healing in the rat
Savaridas, T., Wallace, R. J., Muir, A., Salter, D. M., & Simpson, H. (2012) · Bone and Joint Research · doi:10.1302/2046-3758.111.2000087 · Cited by 10
Bone Substitution and Augmentation in Trauma Surgery with a Resorbable Calcium Phosphate Bone Cement
Bloemers, F. W., Stahl, J., Sarkar, M. R., Linhart, W., Rueckert, U., & Wippermann, B. W. (2004) · European Journal of Trauma · doi:10.1007/s00068-004-1296-x · Cited by 10
Near-Infrared Spectroscopy Allows for Monitoring of Bone Fracture Healing via Changes in Oxygenation
Nowicki, C., & Ganse, B. (2024) · Journal of Functional Biomaterials · doi:10.3390/jfb15120384 · Cited by 9
Evaluating fracture healing using digital X-ray image analysis
Whiley, S. P. (2011) · CME/Continuing medical education · Cited by 13
LUCACIU, O. P., Gheban, D., Şoriţău, O., Băciuț, M. F., Câmpian, R. S., & Băciuț, G. (2015) · Revista română de medicină de laborator · doi:10.1515/rrlm-2015-0009 · Cited by 9
Spanswick, P., Whittier, D. E., Kwong, C. A., Korley, R., Boyd, S. K., & Schneider, P. (2021) · Bone Reports · doi:10.1016/j.bonr.2021.100748 · Cited by 8
Grechenig, W., Peicha, G., Clement, H. G., Fellinger, M., & Mayr, J. M. (2002) · Der Orthopäde · doi:10.1007/s00132-001-0235-3 · Cited by 8
ÖZTAŞ, E., & AVKİ, S. (2015) · Kafkas Universitesi Veteriner Fakultesi Dergisi · doi:10.9775/kvfd.2014.12635 · Cited by 7
Karthas, T., Cook, J. J., Matthews, M. R., Sganga, M. L., Hansen, D., Collier, B., Basile, P., & Cook, E. A. (2018) · The Journal of Foot & Ankle Surgery · doi:10.1053/j.jfas.2017.11.033 · Cited by 7
Blázquez-Carmona, P., Mora‐Macías, J., Morgaz, J., Granados, M. M., Domínguez, J., & Reina-Romo, E. (2023) · PLoS ONE · doi:10.1371/journal.pone.0296510 · Cited by 7
Moss, C., Weinrich, N., Sass, W., & Mueller, J. (2010) · International Symposium on Applied Sciences in Biomedical and Communication Technologies · doi:10.1109/isabel.2010.5702902 · Cited by 9
Vien, B. S., Chiu, W. K., Russ, M. K., & Fitzgerald, M. (2020) · Structural Health Monitoring · doi:10.1177/1475921720978224 · Cited by 7
Wolff, C. G., Warmerdam, E., Dahmen, T., Pohlemann, T., Slusallek, P., & Ganse, B. (2025) · Sensors · doi:10.3390/s25082475 · Cited by 6
Scholz, O., Nowicki, C., Warmerdam, E., Rother, S., & Ganse, B. (2025) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2025.117442 · Cited by 6
Summers, N. J., Ashcraft, J. F., Badri, H., Mostafa, J., Barrett, B., Sganga, M. L., Cook, J. J., Basile, P., & Cook, E. A. (2015) · The Journal of Foot & Ankle Surgery · doi:10.1053/j.jfas.2014.12.030 · Cited by 6
Oulianski, M., Avraham, D., & Lubovsky, O. (2022) · Trauma Care · doi:10.3390/traumacare2030040 · Cited by 6
Serum N-terminal telopeptide of type I collagen as an early marker of fracture nonunion in rabbits
Lin, J., Shi, Z., Ning-jiang, S., Wang, J., Li, Z.-M., & Xiao, J. (2016) · Experimental and Therapeutic Medicine · doi:10.3892/etm.2016.3839 · Cited by 6
Warmerdam, E., Orth, M., Müller, M., Pohlemann, T., & Ganse, B. (2025) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2025.1536738 · Cited by 5
Labus, K. M., Wolynski, J. G., Easley, J. T., Stewart, H. L., Ilić, M. M., Notaroš, B. M., Zagrocki, T., Puttlitz, C. M., & McGilvray, K. C. (2023) · Injury · doi:10.1016/j.injury.2023.111080 · Cited by 5
Hou, Q., Zhu, Q., Wu, Y., Li, R., Li, D., Zhang, Y., & Ruan, Q. (2010) · Journal of Bionic Engineering · doi:10.1016/s1672-6529(10)60264-8 · Cited by 5
Sarifah, N., Epsilawati, L., Azhari, A., Satari, M. H., Priosoeryanto, B. P., Hatta, I., & Fitriyana, A. N. (2021) · Jurnal Radiologi Dentomaksilofasial Indonesia (JRDI) · doi:10.32793/jrdi.v5i3.740 · Cited by 4
Metabolic Measurement Techniques to Assess Bone Fracture Healing: A Preliminary Study
Severns, A. E., Lee, Y.-P., Nelson, S. D., Johnson, E. E., & Kabo, J. M. (2004) · Clinical Orthopaedics and Related Research · doi:10.1097/01.blo.0000128286.98083.2a · Cited by 5
Electrical Impedance Characterization of Bone Fractures in Presence of an Intramedullary Nail
Li, Y., Mikkelsen, J. H., Zhekov, S. S., Jensen, O. K., Frost, M. W., Kold, S., Pedersen, G. F., & Shen, M. (2020) · IEEE International Conference on Bioinformatics and Bioengineering (BIBE) · doi:10.1109/bibe50027.2020.00119 · Cited by 3
In vivo standardization of bone ultrasonometry of the clavicle
Mandarano-Filho, L. G., Bezuti, M. T., & Barbieri, C. H. (2016) · Clinics · doi:10.6061/clinics/2016(03)04 · Cited by 3
Fracture Healing and Imaging Evaluation
Roth, T. D., Ladd, L. M., & Kempton, L. B. (2017) · Current Radiology Reports · doi:10.1007/s40134-017-0221-0 · Cited by 3
An Electronic Osteosynthesis Implant for Continuous Load Monitoring using a Strain Gauge
Adam, C., Barth, T., Munch, M., Seide, K., & Krautschncider, W. H. (2021) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas49922.2021.9644959 · Cited by 3
Assessment of Bone Healing: Opportunities to Improve the Standard of Care
Shariyate, M. J., Kheir, N., Caro, D., Abbasian, M., Rodriguez, E. K., Snyder, B. D., & Nazarian, A. (2023) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.22.01224 · Cited by 3
Design of osteosynthesis plate for detecting bone union using wire natural frequency
Chancharoen, P., Tangpornprasert, P., Amarase, C., Tantavisut, S., & Virulsri, C. (2024) · Scientific Reports · doi:10.1038/s41598-024-63530-w · Cited by 3
Radiographic Union Scoring Scale for Determining Consolidation Rates in the Calcaneus
Sganga, M. L., Summers, N. J., Barrett, B., Matthews, M. R., Karthas, T., Johnson, L. J., Cook, J. J., Basile, P., & Cook, E. A. (2017) · The Journal of Foot & Ankle Surgery · doi:10.1053/j.jfas.2017.05.035 · Cited by 3
Quantification of the bone healing process using information of B-Mode ultrasound image
Al-Nashash, H., Mir, H., Al-Marzouqi, S., Al-Kendi, S., & Khalaf, K. (2012) · 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/embc.2012.6346952 · Cited by 2
“A review of literature reveals that ultrasound provides a promising non-invasive, safe, objective means of monitoring and quantifying the bone healing process, which has the potential to improve the current subjective clinical fracture assessment [6-9].”
BackgroundLenz, J. E., Huber, L., Szymski, D., Alt, V., Rupp, M., & Weber, J. (2024) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s00402-024-05736-1 · Cited by 2
Warmerdam, E., Baumgartner, S., Pohlemann, T., & Ganse, B. (2024) · Scientific Reports · doi:10.1038/s41598-024-75732-3 · Cited by 2
Assessment of Bone Healing Using Ultrasound
Al-Nashash, H. A., & Qaddoumi, N. N. (2011) · Springer eBooks · doi:10.1007/978-1-4614-1180-2_12 · Cited by 2
Dimitriou, R. I., & Giannoudis, P. V. (2014) · Springer eBooks · doi:10.1007/978-3-642-34746-7_145 · Cited by 2
The Use of Digital X-Ray to Monitor Decalcification in Sheep Femora
Dawson, S. P., Ross, E., MacGillivray, T., Muir, A., & Simpson, H. (2009) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-642-03879-2_91 · Cited by 2
Time to Union as a Measure of Effectiveness
Ring, D. (2012) · Cited by 4
THE EFFECT OF DENERVATION ON FRACTURE HEALING , AN EXPERIMENTAL STUDY ON RABBITS
Hamdan, T. A., Saeed, M. A. M., & ISMAEL, A. S. (2014) · Basrah Journal of Surgery · doi:10.33762/bsurg.2014.98063 · Cited by 2
Lachman, R. S. (2007) · Elsevier eBooks · doi:10.1016/b978-0-323-01931-6.50035-9 · Cited by 2
Al-Smadi, F., Lin, Z., Li, N., Liao, J., Al-Smadi, S., Abudourusuli, X., Xie, X., Yu, C., Li, Y., Liu, M., et al. (2026) · Journal of Orthopaedic Translation · doi:10.1016/j.jot.2026.101172 · Cited by 1
Ultrasonic Monitoring of Fracture Healing
Protopappas, V. C., Vavva, M. G., Malizos, Κ. Ν., Polyzos, D., & Fotiadis, D. I. (2010) · Springer eBooks · doi:10.1007/978-94-007-0017-8_14 · Cited by 1
Radiologic Evaluation of Femur Fractures
Vuillermin, C. B., & Bixby, S. D. (2016) · Springer eBooks · doi:10.1007/978-1-4899-7986-5_2 · Cited by 1
Jerome, J. T. J. (2020) · Orthoplastic Surgery · doi:10.1016/j.orthop.2020.10.004 · Cited by 1
Adesina, S. A., Anipole, O. A., Eyesan, S. U., Ikem, I. C., Akinwumi, A. I., Bamigboye, P., & Oyewusi, O. O. (2020) · Nigerian Journal of Orthopaedics and Trauma · doi:10.4103/njot.njot_23_20 · Cited by 1
Perlepe, V., Michoux, N., Kirchgesner, T., Lecouvet, F. E., & Berg, B. V. (2021) · European Journal of Radiology · doi:10.1016/j.ejrad.2021.109618 · Cited by 1
Tibial Fracture Management With Minimally Invasive Plate Osteosynthesis (MIPO) In Dogs
Das, B. C. (2010) · Cited by 1
50 YEARS AGO IN CORR: Disability Following Crush Fracture of the Calcaneus by C. F. Ferciot, MD
Brand, R. A. (2007) · Clinical Orthopaedics and Related Research · doi:10.1097/blo.0b013e3180341ed5
Metadata
- Authors
- Blokhuis, T. J., de Bruine, J. H. D., Bramer, J. A. M., den Boer, F. C., Bakker, F. C., Patka, P., Haarman, H. J. T. M., & Manoliu, R. A.
- Affiliations
- Vrije Universiteit Amsterdam (NL)
- Venue
- Skeletal Radiology
- Published
- 2001-03-28
- Volume
- 30
- Issue
- 3
- Pages
- 151-156
- ISSN
- 0364-2348 (ISSN-L)
- 1432-2161
- OpenAlex
- W2052046606
- Cited by
- 113
- References
- 18
- Citations by year
- 2026: 4 · 2025: 3 · 2024: 8 · 2023: 5 · 2022: 6 · 2021: 7 · 2020: 5 · 2019: 3 · 2018: 1 · 2017: 8 · 2016: 4 · 2015: 6 · 2014: 8 · 2013: 3 · 2012: 5
- FWCI
- 2.29
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Skeletal Radiology (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- Funders
- Stryker
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Health Sciences › Medicine › Surgery › Orthopedic Surgery and Rehabilitation
- Keywords
- fracture healing, radiography, interobserver agreement, tibial fractures, osteogenic protein-1, BMP-2, external fixation, radiographic scoring, healing assessment, goats
- MeSH terms
- Animals, Biomechanical Phenomena, Female, Fracture Fixation, Goats, Radiography, Regression Analysis, Tibia, Tibial Fractures, Reproducibility of Results, Observer Variation, Transforming Growth Factor beta, External Fixators, Fracture Healing, Bone Morphogenetic Proteins, Bone Morphogenetic Protein 7
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.