Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 303

The DOI matches its Crossref record.

A fast cardiac gamma camera with dynamic SPECT capabilities: design, system validation and future potential

Open access
Bocher, Moshe, Blevis, Ira M., Tsukerman, Leonid, Shrem, Yigal, Kovalski, Gil, Volokh, Lana·2010·European Journal of Nuclear Medicine and Molecular Imaging

Abstract

PURPOSE: The goal of this study is to present the Discovery NM 530c (DNM), a cardiac SPECT camera, interfacing multi-pinhole collimators with solid-state modules, aiming at slashing acquisition time without jeopardizing quality. DNM resembles PET since it enables 3-D SPECT without detector motion. We further envision how these novel capabilities may help with current and future challenges of cardiac imaging. METHODS: DNM sensitivity, spatial resolution (SR) and energy resolution (ER), count rate response, cardiac uniformity and cardiac defect contrast were measured and compared to a dedicated cardiac, dual-head standard SPECT (S-SPECT) camera. RESULTS: DNM sensitivity was more than threefold higher while SR was notably better. Significantly, SR was the same for (99m)Tc and (201)Tl. ER was improved on DNM and allowed good separation of (99m)Tc and (123)I spectral peaks. Count rate remained linear on DNM up to 612 kcps, while S-SPECT showed severe dead time limitations. Phantom studies revealed comparable uniformity and defect contrast, notwithstanding significantly shorter acquisition time for the DNM. First patient images, including dynamic SPECT, are also presented. CONCLUSION: DNM is raising the bar for expedition and upgrade of practice. It features high sensitivity as well as improved SR, temporal resolution and ER. It enables reduction of acquisition time and fast protocols. Importantly, it is potentially capable of dynamic 3-D acquisition. The new technology is potentially upgradeable and may become a milestone in the evolution of nuclear cardiology as it assumes its key role in molecular imaging of the heart.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00259-010-1488-z

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 303

Metadata

Authors
Bocher, M., Blevis, I. M., Tsukerman, L., Shrem, Y., Kovalski, G., & Volokh, L.
Venue
European Journal of Nuclear Medicine and Molecular Imaging
Published
2010-06-29
Volume
37
Issue
10
Pages
1887-1902
ISSN
  • 1619-7070 (ISSN-L)
  • 1619-7089
OpenAlex
W2089172939
Cited by
303
References
0
FWCI
12.05
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A fast cardiac gamma camera with dynamic SPECT capabilities: design, system validation and future potential. https://app.cochat.ai/papers/10.1007/s00259-010-1488-z
The paper
Bocher, M., Blevis, I. M., Tsukerman, L., Shrem, Y., Kovalski, G., & Volokh, L. (2010). A fast cardiac gamma camera with dynamic SPECT capabilities: design, system validation and future potential. European Journal of Nuclear Medicine and Molecular Imaging. https://doi.org/10.1007/s00259-010-1488-z

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.