Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 294

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Amyloid PET imaging in Alzheimer’s disease: a comparison of three radiotracers

Open access
the Alzheimer’s Disease Neuroimaging Initiative, Landau, S. M., Thomas, B. A., Thurfjell, L., Schmidt, M., Margolin, R., Mintun, M., Pontecorvo, M., Baker, S. L., Jagust, W. J.·2014·European Journal of Nuclear Medicine and Molecular Imaging

Abstract

PurposeThe increasing use of amyloid PET in Alzheimer’s disease research and clinical trials has motivated efforts to standardize methodology. We compared retention of the 11C radiotracer Pittsburgh Compound B (PiB) and that of two 18F amyloid radiotracers (florbetapir and flutemetamol) using two study populations. We also examined the feasibility of converting between tracer-specific measures, using PiB as the common link between the two 18F tracers.MethodsOne group of 40 subjects underwent PiB and flutemetamol imaging sessions and a separate group of 32 subjects underwent PiB and florbetapir imaging sessions. We compared cortical and white matter retention for each 18F tracer relative to that of PiB, as well as retention in several reference regions and image analysis methods. Correlations between tracer pairs were used to convert tracer-specific threshold values for amyloid positivity between tracers.ResultsCortical retention for each pair of tracers was strongly correlated regardless of reference region (PiB–flutemetamol, ρ = 0.84–0.99; PiB–florbetapir, ρ = 0.83–0.97) and analysis method (ρ = 0.90–0.99). Compared to PiB, flutemetamol had higher white matter retention, while florbetapir had lower cortical retention. Two previously established independent thresholds for amyloid positivity were highly consistent when values were converted between tracer pairs.ConclusionDespite differing white and grey matter retention characteristics, cortical retention for each 18F tracer was highly correlated with that of PiB, enabling conversion of thresholds across tracer measurement scales with a high level of internal consistency. Standardization of analysis methods and measurement scales may facilitate the comparison of amyloid PET data obtained using different tracers.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00259-014-2753-3

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 21 references

Cited by

See all 294

Metadata

Authors
Initiative, T. A. D. N., Landau, S. M., Thomas, B. A., Thurfjell, L., Schmidt, M., Margolin, R., Mintun, M., Pontecorvo, M., Baker, S. L., & Jagust, W. J.
Venue
European Journal of Nuclear Medicine and Molecular Imaging
Published
2014-03-20
Volume
41
Issue
7
Pages
1398-1407
ISSN
  • 1619-7070 (ISSN-L)
  • 1619-7089
OpenAlex
W2010695389
Cited by
294
References
21
FWCI
16.84
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Amyloid PET imaging in Alzheimer’s disease: a comparison of three radiotracers. https://app.cochat.ai/papers/10.1007/s00259-014-2753-3
The paper
Initiative, T. A. D. N., Landau, S. M., Thomas, B. A., Thurfjell, L., Schmidt, M., Margolin, R., Mintun, M., Pontecorvo, M., Baker, S. L., & Jagust, W. J. (2014). Amyloid PET imaging in Alzheimer’s disease: a comparison of three radiotracers. European Journal of Nuclear Medicine and Molecular Imaging. https://doi.org/10.1007/s00259-014-2753-3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.