Harmonizing FDG PET quantification while maintaining optimal lesion detection: prospective multicentre validation in 517 oncology patients
Open accessAbstract
PURPOSE: Point-spread function (PSF) or PSF + time-of-flight (TOF) reconstruction may improve lesion detection in oncologic PET, but can alter quantitation resulting in variable standardized uptake values (SUVs) between different PET systems. This study aims to validate a proprietary software tool (EQ.PET) to harmonize SUVs across different PET systems independent of the reconstruction algorithm used. METHODS: NEMA NU2 phantom data were used to calculate the appropriate filter for each PSF or PSF+TOF reconstruction from three different PET systems, in order to obtain EANM compliant recovery coefficients. PET data from 517 oncology patients were reconstructed with a PSF or PSF+TOF reconstruction for optimal tumour detection and an ordered subset expectation maximization (OSEM3D) reconstruction known to fulfil EANM guidelines. Post-reconstruction, the proprietary filter was applied to the PSF or PSF+TOF data (PSFEQ or PSF+TOFEQ). SUVs for PSF or PSF+TOF and PSFEQ or PSF+TOFEQ were compared to SUVs for the OSEM3D reconstruction. The impact of potential confounders on the EQ.PET methodology including lesion and patient characteristics was studied, as was the adherence to imaging guidelines. RESULTS: For the 1380 tumour lesions studied, Bland-Altman analysis showed a mean ratio between PSF or PSF+TOF and OSEM3D of 1.46 (95%CI: 0.86-2.06) and 1.23 (95%CI: 0.95-1.51) for SUVmax and SUVpeak, respectively. Application of the proprietary filter improved these ratios to 1.02 (95%CI: 0.88-1.16) and 1.04 (95%CI: 0.92-1.17) for SUVmax and SUVpeak, respectively. The influence of the different confounding factors studied (lesion size, location, radial offset and patient's BMI) was less than 5%. Adherence to the European Association of Nuclear Medicine (EANM) guidelines for tumour imaging was good. CONCLUSION: These data indicate that it is not necessary to sacrifice the superior lesion detection and image quality achieved by newer reconstruction techniques in the quest for harmonizing quantitative comparability between PET systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Figures





![Fig. 6 Impact of the size of the lesion (a), the location of the lesion across the field of view [radial offset (b)], the anatomical site of the lesion (c), and patient BMI (d) on the ratio between PSFEQ/PSF+TOFEQ and OSEM PET quantitative values (left panels SUVmax, right panels SUVpeak). Note that 213 lesions were not measurable and therefore not included in the “per size” analysis. The differences among different groups were tested with the Kruskal-Wallis test, and a post hoc test was performed with the Dunn test for multiple comparisons; *, **, and *** indicate two-tailed p < 0.05, p < 0.01, and p < 0.001, respectively](/paper-figures/83e10ed04dec4fe5a4b262d834063855/harmonizing-fdg-pet-quantification-while-maintaining-optimal-lesion-detection-figure-6.jpg)
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Compared with non-PSF reconstructed images, this can increase lesion SUVmax, SUVmean and SUVpeak by up to 30% on average [100,101,102].”
From Influences on PET Quantification and Interpretation (2022) · cites this paper as [100]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“With appropriate filter width (FWHM) based on sphere CR from standardized phantom measurements, PSF-induced SUV increases can be negated, resulting in comparable lesion SUVs to those in non-PSF data.”
From Influences on PET Quantification and Interpretation (2022) · cites this paper as [100]
The cited source says what the claim attributes to it.
In the citing paper
“This improves reconstructed spatial resolution [97,98] and increases lesion SUV [99,100] but can lead to overestimation of the true activity due to so-called Gibbs’ artifacts [92,93].”
From Influences on PET Quantification and Interpretation (2022) · cites this paper as [100]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Beckett, A. H., Rowland, M., & TURNER, P. (1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,917
From RECIST to PERCIST: Evolving Considerations for PET Response Criteria in Solid Tumors
Wahl, R. L., Jacene, H., Kasamon, Y., & Lodge, M. A. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.057307 · Cited by 3,777
FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0
Boellaard, R., Delgado-Bolton, R., Oyen, W. J. G., Giammarile, F., Tatsch, K., Eschner, W., Verzijlbergen, F. J., Barrington, S. F., Pike, L. C., Weber, W. A., et al. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-014-2961-x · Cited by 3,303
Young, H. E., Baum, R. P., Cremerius, U., Herholz, K., Hoekstra, O. S., Lammertsma, A. A., Pruim, J., & Price, P. (1999) · European Journal of Cancer · doi:10.1016/s0959-8049(99)00229-4 · Cited by 1,716
Barrington, S. F., Mikhaeel, N. G., Kostakoğlu, L., Meignan, M. A., Hutchings, M., Müeller, S., Schwartz, L. H., Zucca, E., Fisher, R. I., Trotman, J., et al. (2014) · Journal of Clinical Oncology · doi:10.1200/jco.2013.53.5229 · Cited by 1,663
Self-citationFDG PET and PET/CT: EANM procedure guidelines for tumour PET imaging: version 1.0
Boellaard, R., O’Doherty, M. J., Weber, W., Mottaghy, F. M., Lonsdale, M. N., Stroobants, S. G., Oyen, W. J. G., Kotzerke, J., Hoekstra, O. S., Pruim, J., et al. (2009) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-009-1297-4 · Cited by 1,329
Procedure guideline for tumor imaging with 18F-FDG PET/CT 1.0.
Delbeke, D., Coleman, R. E., Guiberteau, M. J., Brown, M. L., Royal, H. D., Siegel, B. A., Townsend, D. W., Berland, L. L., Parker, J. A., Hubner, K., et al. (2006) · PubMed · Cited by 689
Procedure guideline for tumor imaging with F-18 FDG PET/CT
Delbeke, D., Coleman, R. E., Guiberteau, M. J., Brown, M. L., Royal, H. D., Siegel, B. A., Townsend, D. W., Berland, L. L., Parker, J. A., Hübner, K. F., et al. (2006) · Cited by 620
Physical and clinical performance of the mCT time-of-flight PET/CT scanner
Jakoby, B., Bercier, Y., Conti, M., Casey, M. E., Bendriem, B., & Townsend, D. W. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/8/004 · Cited by 487
Cited by
Sorted by citations
Aide, N., Lasnon, C., Veit-Haibach, P., Sera, T., Sattler, B., & Boellaard, R. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-017-3740-2 · Cited by 344
Self-citationMeignan, M. A., Cottereau, A., Versari, A., Chartier, L., Dupuis, J., Boussetta, S., Grassi, I., Casasnovas, O., Haïoun, C., Tilly, H., et al. (2016) · Journal of Clinical Oncology · doi:10.1200/jco.2016.66.9440 · Cited by 325
Quantification, improvement, and harmonization of small lesion detection with state-of-the-art PET
van der Vos, C. S., Koopman, D., Rijnsdorp, S., Arends, A. J., Boellaard, R., van Dalen, J. A., Lubberink, M., Willemsen, A. T. M., & Visser, E. P. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-017-3727-z · Cited by 206
How We Read Oncologic FDG PET/CT
Hofman, M. S., & Hicks, R. J. (2016) · Cancer Imaging · doi:10.1186/s40644-016-0091-3 · Cited by 155
Self-citationRadiomics in Nuclear Medicine Applied to Radiation Therapy: Methods, Pitfalls, and Challenges
Reuzé, S., Schernberg, A., Orlhac, F., Sun, R., Chargari, C., Dercle, L., Deutsch, É., Buvat, I., & Robert, C. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2018.05.022 · Cited by 128
Clinical evaluation of the radiolanthanide terbium-152: first-in-human PET/CT with 152 Tb-DOTATOC
Baum, R. P., Singh, A., Benešová, M., Vermeulen, C. E., Gnesin, S., Köster, U., Johnston, K., Müller, D., Senftleben, S., Kulkarni, H., et al. (2017) · Dalton Transactions · doi:10.1039/c7dt01936j · Cited by 94
Point-spread function reconstructed PET images of sub-centimeter lesions are not quantitative
Munk, O. L., Tolbod, L. P., Hansen, S. B., & Bogsrud, T. V. (2017) · EJNMMI Physics · doi:10.1186/s40658-016-0169-9 · Cited by 84
New PET technologies – embracing progress and pushing the limits
Aide, N., Lasnon, C., Kesner, A., Levin, C. S., Buvat, I., Iagaru, A., Hermann, K., Badawi, R. D., Cherry, S. R., Bradley, K. M., et al. (2021) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-021-05390-4 · Cited by 73
Self-citationWong, A. N. M., Callahan, J., Keyaerts, M., Neyns, B., Mangana, J., Aberle, S., Herschtal, A., Fullerton, S., Milne, D., Iravani, A., et al. (2020) · Cancer Imaging · doi:10.1186/s40644-020-00313-2 · Cited by 71
Self-citationMetabolic Tumor Volume in Lymphoma: Hype or Hope?
Schöder, H. M., & Moskowitz, C. H. (2016) · Journal of Clinical Oncology · doi:10.1200/jco.2016.69.3747 · Cited by 68
Cottereau, A.-S., Hapdey, S., Chartier, L., Modzelewski, R., Casasnovas, O., Itti, E., Tilly, H., Vera, P., Meignan, M. A., & Becker, S. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.180406 · Cited by 64
Repetitive 18F-FDG-PET/CT in patients with large-vessel giant-cell arteritis and controlled disease
de Boysson, H., Aide, N., Liozon, É., Lambert, M., Parienti, J., Monteil, J., Huglo, D. G., Bienvenu, B., Manrique, A., & Aouba, A. (2017) · European Journal of Internal Medicine · doi:10.1016/j.ejim.2017.08.013 · Cited by 63
Self-citationWeyts, K., Lasnon, C., Ciappuccini, R., Lequesne, J., Corroyer-Dulmont, A., Quak, E., Clarisse, B., Roussel, L., Bardet, S., & Jaudet, C. (2022) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-022-05800-1 · Cited by 59
Self-citationNCTN Assessment on Current Applications of Radiomics in Oncology
Nie, K., Al‐Hallaq, H., Li, X. A., Benedict, S., Sohn, J. W., Moran, J. M., Yong Fan, A., Huang, M., Knopp, M. V., Michalski, J. M., et al. (2019) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2019.01.087 · Cited by 63
Fournier, L., de Geus-Oei, L. D., Regge, D., Oprea-Lager, D., D'Anastasi, M., Bidaut, L., Bäuerle, T., Lopci, E., Cappello, G., Lecouvet, F., et al. (2022) · Frontiers in Oncology · doi:10.3389/fonc.2021.800547 · Cited by 49
Lasnon, C., Majdoub, M., Lavigne, B., Dô, P., Madelaine, J., Visvikis, D., Hatt, M., & Aide, N. (2016) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-016-3441-2 · Cited by 53
Self-citationInfluences on PET Quantification and Interpretation
Rogasch, J. M. M., Hofheinz, F., van Heek, L., Voltin, C.-A., Boellaard, R., & Kobe, C. (2022) · Diagnostics · doi:10.3390/diagnostics12020451 · Cited by 57
“To correct for these increases, an additional Gaussian filter can be applied during image reconstruction or to the final images [100,102].”
BackgroundA review of harmonization strategies for quantitative PET
Akamatsu, G., Tsutsui, Y., Daisaki, H., Mitsumoto, K., Baba, S., & Sasaki, M. (2023) · Annals of Nuclear Medicine · doi:10.1007/s12149-022-01820-x · Cited by 52
Rufini, V., Garganese, G., Ieria, F. P., Pasciuto, T., Fragomeni, S. M., Gui, B., Florit, A., Inzani, F. S., Zannoni, G. F., Scambia, G., et al. (2021) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-021-05257-8 · Cited by 49
Bone Metastases Are Measurable: The Role of Whole-Body MRI and Positron Emission Tomography
Oprea‐Lager, D. E., Cysouw, M. C. F., Boellaard, R., Deroose, C. M., de Geus‐Oei, L., Lopci, E., Bidaut, L. M., Herrmann, K., Fournier, L. S., Bäuerle, T., et al. (2021) · Frontiers in Oncology · doi:10.3389/fonc.2021.772530 · Cited by 49
Experimental validation of absolute SPECT/CT quantification for response monitoring in breast cancer
Collarino, A., Arias‐Bouda, L. M. P., Olmos, R. A. V., van der Tol, P., Dibbets‐Schneider, P., de Geus‐Oei, L., & van Velden, F. H. P. (2018) · Medical Physics · doi:10.1002/mp.12880 · Cited by 42
Does PET SUV Harmonization Affect PERCIST Response Classification?
Quak, E., Roux, P. L., Lasnon, C., Robin, P., Hofman, M. S., Bourhis, D., Callahan, J., Binns, D., Desmonts, C., Salaün, P., et al. (2016) · Journal of Nuclear Medicine · doi:10.2967/jnumed.115.171983 · Cited by 41
Self-citationLasnon, C., Salomon, T., Desmonts, C., Dô, P., Oulkhouir, Y., Madelaine, J., & Aide, N. (2016) · Annals of Nuclear Medicine · doi:10.1007/s12149-016-1135-2 · Cited by 41
Self-citationDevriese, J., Beels, L., Maes, A., de Wiele, C. V., & Pottel, H. (2018) · EJNMMI Physics · doi:10.1186/s40658-018-0235-6 · Cited by 37
Lasnon, C., Enilorac, B., Popotte, H., & Aide, N. (2017) · EJNMMI Research · doi:10.1186/s13550-017-0279-y · Cited by 35
Self-citationThe value of the Standardized Uptake Value (SUV) and Metabolic Tumor Volume (MTV) in lung cancer.
Hicks, R. (2022) · Seminars in nuclear medicine · doi:10.1053/j.semnuclmed.2022.04.007 · Cited by 33
Self-citationRufini, V., Lorusso, M., Inzani, F. S., Pasciuto, T., Triumbari, E. K. A., Grillo, L. R., Locco, F., Margaritora, S., Pescarmona, E. O., & Rindi, G. (2022) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-022-05848-z · Cited by 31
Reducing Radiation Exposure to Paediatric Patients Undergoing [18F]FDG-PET/CT Imaging
Kertész, H., Beyer, T., London, K., Saleh, H., Chung, D. K. V., Rausch, I., Cal-González, J., Kitsos, T., & Kench, P. L. (2021) · Molecular Imaging and Biology · doi:10.1007/s11307-021-01601-4 · Cited by 31
J-Hart study group, Tsutsui, Y., Daisaki, H., Akamatsu, G., Umeda, T., Ogawa, M., Kajiwara, H., Kawase, S., Sakurai, M., Nishida, H., et al. (2018) · EJNMMI Research · doi:10.1186/s13550-018-0438-9 · Cited by 29
Houdu, B., Lasnon, C., Licaj, I., Thomas, G., Do, P., Guizard, A.-V., Desmonts, C., & Aide, N. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-018-4151-8 · Cited by 37
Self-citationBoellaard, R. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-015-3182-7 · Cited by 28
Beichel, R., Smith, B. J., Bauer, C., Ulrich, E. J., Ahmadvand, P., Budzevich, M. M., Gillies, R. J., Goldgof, D. B., Grkovski, M., Hamarneh, G., et al. (2016) · Medical Physics · doi:10.1002/mp.12041 · Cited by 28
Taralli, S., Scolozzi, V., Foti, M., Ricciardi, S., Forcione, A. R., Cardillo, G., & Calcagni, M. L. (2018) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-018-4226-6 · Cited by 28
Lasnon, C., Quak, E., Roux, P. L., Robin, P., Hofman, M. S., Bourhis, D., Callahan, J., Binns, D., Desmonts, C., Salaün, P., et al. (2017) · EJNMMI Physics · doi:10.1186/s40658-017-0185-4 · Cited by 27
Self-citationDoes PET Reconstruction Method Affect Deauville Score in Lymphoma Patients?
Enilorac, B., Lasnon, C., Nganoa, C., Fruchart, C., Gac, A., Damaj, G. L., & Aide, N. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.202721 · Cited by 27
Self-citationFour-dimensional quantitative analysis using FDG-PET in clinical oncology
Tamaki, N., Hirata, K., Kotani, T., Nakai, Y., Matsushima, S., & Yamada, K. (2023) · Japanese Journal of Radiology · doi:10.1007/s11604-023-01411-4 · Cited by 22
Anatomical Grading for Metabolic Activity of Brown Adipose Tissue
Becker, A. S., Nagel, H. W., Wolfrum, C., & Burger, I. A. (2016) · PLoS ONE · doi:10.1371/journal.pone.0149458 · Cited by 24
Cottereau, A., Buvat, I., Kanoun, S., Versari, A., Casasnovas, O., Chauvie, S., Clerc, J., Gallamini, A., & Meignan, M. A. (2018) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-018-4005-4 · Cited by 24
Optimization of SPECT/CT imaging protocols for quantitative and qualitative 99mTc SPECT
Kupitz, D., Wissel, H., Wuestemann, J., Bluemel, S., Pech, M., Amthauer, H., Kreissl, M. C., & Großer, O. S. (2021) · EJNMMI Physics · doi:10.1186/s40658-021-00405-3 · Cited by 26
Prenosil, G. A., Hentschel, M., Weitzel, T., Sari, H., Shi, K., Afshar‐Oromieh, A., & Rominger, A. (2022) · EJNMMI Physics · doi:10.1186/s40658-022-00455-1 · Cited by 23
Pontoizeau, C., Girard, A., Mesbah, H., Haumont, L.-A., Devillers, A., Tempescul, A., Salaün, P., Lamy, T., Jeune, F. L., & Palard-Novello, X. (2019) · Clinical Nuclear Medicine · doi:10.1097/rlu.0000000000002879 · Cited by 22
Daisaki, H., Kitajima, K., Nakajo, M., Watabe, T., Ito, K., Sakamoto, F., Nakahara, T., Ishibashi, M., & Toriihara, A. (2021) · Scientific Reports · doi:10.1038/s41598-021-87942-0 · Cited by 21
Keller, H., Shek, T. L. T., Driscoll, B., Xu, Y., Nghiem, B., Nehmeh, S. A., Grkovski, M., Schmidtlein, C. R., Budzevich, M. M., Balagurunathan, Y., et al. (2022) · Tomography · doi:10.3390/tomography8020091 · Cited by 21
Miwa, K., Wagatsuma, K., Iimori, T., Sawada, K., Kamiya, T., Sakurai, M., Miyaji, N., Murata, T., & Sato, E. (2018) · Physica Medica · doi:10.1016/j.ejmp.2018.07.001 · Cited by 20
[18F]FDG PET/MRI enables early chemotherapy response prediction in pancreatic ductal adenocarcinoma
Harder, F. N., Jungmann, F., Kaissis, G. A., Lohöfer, F. K., Ziegelmayer, S., Havel, D., Quante, M., Reichert, M., Schmid, R. M., Demir, İ. E., et al. (2021) · EJNMMI Research · doi:10.1186/s13550-021-00808-4 · Cited by 20
Ptáček, J., Karhan, P., & Fiala, P. (2017) · Physica Medica · doi:10.1016/j.ejmp.2017.06.002 · Cited by 18
Validation of phantom-based harmonization for patient harmonization
Panetta, J. V., Daube-Witherspoon, M. E., & Karp, J. S. (2017) · Medical Physics · doi:10.1002/mp.12311 · Cited by 17
Lasnon, C., Houdu, B., Kammerer, E., Salomon, T., Devreese, J., Lebasnier, A., & Aide, N. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-015-3214-3 · Cited by 17
Self-citationTsutsui, Y., Awamoto, S., Himuro, K., Umezu, Y., Baba, S., & Sasaki, M. (2018) · Europe PMC (PubMed Central) · doi:10.22038/aojnmb.2017.26684.1186 · Cited by 15
Monsef, A., Ay, M., Sheikhzadeh, P., Geramifar, P., Rahmim, A., & Ghafarian, P. (2022) · Nuclear medicine communications · doi:10.1097/mnm.0000000000001598 · Cited by 11
Advancing Precision Nuclear Medicine and Molecular Imaging for Lymphoma
Wright, C., Maly, J. J., Zhang, J., & Knopp, M. V. (2016) · PET Clinics · doi:10.1016/j.cpet.2016.08.005 · Cited by 14
Song, Y., Meng, X., Cao, Z., Zhao, W., Zhang, Y., Guo, R., Zhou, X. H., Yang, Z. H., & Li, N. (2023) · EJNMMI Physics · doi:10.1186/s40658-023-00540-z · Cited by 13
Kit, N. H., Dugué, A. E., Sevin, E., Allouache, N., Lesaunier, F., Joly, F., & Aide, N. (2015) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000000457 · Cited by 13
Self-citationChen, W., Li, Y., Li, Z., Jiang, Y., Cui, Y., Zeng, J., Mo, Y., Tang, S., Li, S., Liu, L., et al. (2024) · Journal of Nuclear Medicine · doi:10.2967/jnumed.123.266948 · Cited by 11
Andela, S. B., Amthauer, H., Furth, C., Rogasch, J. M. M., Beck, M., Mehrhof, F. B., Ghadjar, P., van den Hoff, J., Klatte, T., Tahbaz, R., et al. (2024) · Radiation Oncology · doi:10.1186/s13014-024-02483-w · Cited by 12
Cysouw, M. C. F., Kramer, G. M., Heijtel, D., Schuit, R. C., Morris, M. J., van den Eertwegh, A. J. M., Voortman, J., Hoekstra, O. S., Oprea‐Lager, D. E., & Boellaard, R. (2019) · EJNMMI Research · doi:10.1186/s13550-019-0531-8 · Cited by 11
Kawashima, K., Kato, K., Tomabechi, M., Matsuo, M., Otsuka, K., Ishida, K., Nakamura, R., & Ehara, S. (2016) · British Journal of Radiology · doi:10.1259/bjr.20150938 · Cited by 11
A Bio-Imaging Signature as a Predictor of Clinical Outcomes in Locally Advanced Pancreatic Cancer
Fiore, M., Taralli, S., Trecca, P., Scolozzi, V., Marinelli, L., Triumbari, E. K. A., Caputo, D. D., Angeletti, S., Ciccozzi, M., Coppola, A., et al. (2020) · Cancers · doi:10.3390/cancers12082016 · Cited by 10
Jiménez-Ortega, E., Ureba, A., Baeza, J. A., Barbeiro, A. R., Balcerzyk, M., Parrado‐Gallego, Á., Wals-Zurita, A., Gómez, F. J. G., & Leal, A. (2019) · PLoS ONE · doi:10.1371/journal.pone.0210549 · Cited by 9
Hicks, R. J., & den Abbeele, A. D. V. (2022) · Cancer Imaging · doi:10.1186/s40644-022-00486-y · Cited by 9
Self-citationMattoli, M. V., Calcagni, M. L., Taralli, S., Indovina, L., Spottiswoode, B. S., & Giordano, A. (2019) · Molecular Imaging and Biology · doi:10.1007/s11307-019-01342-5 · Cited by 9
Taralli, S., Scolozzi, V., Boldrini, L., Lenkowicz, J., Pelliccioni, A., Lorusso, M., Attieh, O. A., Ricciardi, S., Carleo, F., Cardillo, G., et al. (2021) · Frontiers in Medicine · doi:10.3389/fmed.2021.664529 · Cited by 9
On the Cutoff of Baseline Total Metabolic Tumor Volume in High–Tumor-Burden Follicular Lymphoma
Laffon, É., & Marthan, R. (2017) · Journal of Clinical Oncology · doi:10.1200/jco.2016.70.6150 · Cited by 9
Wu, L., Zhang, Z.-S., Jiang, C., Li, L., Sun, X.-J., Bai, M., Liu, M., Xiong, K., Shang, J., Yu, J.-M., et al. (2025) · Advancement of science · doi:10.1002/advs.202413125 · Cited by 13
Machado, M. A. D., Menezes, V. O. M. D. O., Namías, M., Vieira, N. S., Queiroz, C. C., Matheoud, R., Alessio, A. M., & Oliveira, M. L. (2018) · Journal of Nuclear Medicine Technology · doi:10.2967/jnmt.118.213405 · Cited by 8
Allioux, F., Damaj, G. L., Vilque, J., Nganoa, C., Gac, A., Aide, N., & Lasnon, C. (2021) · Leukemia & lymphoma/Leukemia and lymphoma · doi:10.1080/10428194.2021.1948028 · Cited by 7
Self-citationLasnon, C., Enilorac, B., & Aide, N. (2018) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-018-3938-y · Cited by 7
Self-citationRadioguided surgery with β decay: A feasibility study in cervical cancer
Collarino, A., Florit, A., Bizzarri, N., Lanni, V., Morganti, S., Summa, M. D., Vizzielli, G., Fanfani, F., Mirabelli, R., Ferrandina, G., et al. (2023) · Physica Medica · doi:10.1016/j.ejmp.2023.102658 · Cited by 6
Using PET for therapy monitoring in oncological clinical trials: challenges ahead
Deroose, C. M., Stroobants, S. G., Liu, Y., Shankar, L. K., & Bourguet, P. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-017-3689-1 · Cited by 6
Using EQ·PET to reduce reconstruction-dependent variations in [ 18 F]FDG-PET brain imaging
Vanhoutte, M., Semah, F., Lopes, R., Jaillard, A., Petyt, G., Aziz, A.-L., Lahousse, H., Declerck, J. M., Pasquier, F., Spottiswoode, B. S., et al. (2019) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab35b4 · Cited by 5
Jin, S. O., Mérida, I., Stavropoulos, I., Elwes, R. D. C., Lam, T., Guedj, É., Girard, N. J., Costes, N., & Hammers, A. (2023) · EJNMMI Research · doi:10.1186/s13550-023-01023-z · Cited by 5
Iizuka, H., Daisaki, H., Ogawa, M., Yoshida, K., & Kaneta, T. (2019) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000001037 · Cited by 5
Interim PET in lymphoma: from Deauville to Peking criteria. On the road, again…
Meignan, M. A., & Cottereau, A. (2017) · Leukemia & lymphoma/Leukemia and lymphoma · doi:10.1080/10428194.2017.1368078 · Cited by 5
Taralli, S., Orlandi, A., Pafundi, P. C., Tempesta, V., Leone, A. D., Pontolillo, L., Scardina, L., Lorusso, M., Paris, I., & Calcagni, M. L. (2025) · La radiologia medica · doi:10.1007/s11547-025-01961-9 · Cited by 4
You, H., Sanli, Y., & Subramaniam, R. M. (2019) · American Journal of Roentgenology · doi:10.2214/ajr.18.21067 · Cited by 4
Impact of scanner harmonization on PET-based treatment response assessment in metastatic melanoma
Weisman, A. J., Bradshaw, T., Namías, M., & Jeraj, R. (2020) · Physics in Medicine and Biology · doi:10.1088/1361-6560/abb6bb · Cited by 4
Terbium radionuclides for theranostics
Müller, C., Schibli, R., Bernhardt, P., Köster, U., & van der Meulen, N. P. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822960-6.00076-4 · Cited by 4
Weyts, K., Lequesne, J., Johnson, A., Curcio, H., Parzy, A., Coquan, E., & Lasnon, C. (2024) · EJNMMI Research · doi:10.1186/s13550-024-01128-z · Cited by 4
Taralli, S., Scolozzi, V., Triumbari, E. K. A., Carleo, F., Martino, M., Massimi, A. R. D., Ricciardi, S., Cardillo, G., & Calcagni, M. L. (2020) · The Quarterly Journal of Nuclear Medicine and Molecular Imaging · doi:10.23736/s1824-4785.19.03140-6 · Cited by 4
Samim, M., Prevoo, W., der Veen, B. J. D. W., Kuhlmann, K. F. D., Ruers, T. J. M., van Hillegersberg, R., van den Bosch, M. A. A. J., Verkooijen, H. M., Lam, M. G. E. H., & Stokkel, M. P. M. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-017-3637-0 · Cited by 4
Sipilä, O., Liukkonen, J., Halme, H.-L., Tolvanen, T., Sohlberg, A. O., Hakulinen, M. A., Manninen, A.-L., Tahvanainen, K. U. O., Tunninen, V., Ollikainen, T., et al. (2023) · EJNMMI Physics · doi:10.1186/s40658-023-00551-w · Cited by 3
Tanaka, A., Sekine, T., ter Voert, E. T., Zeimpekis, K., Delso, G., Barbosa, F. D. G., Warnock, G., Kumita, S., Veit-Haibach, P., & Huellner, M. (2022) · Frontiers in Medicine · doi:10.3389/fmed.2022.796085 · Cited by 5
Balcerzyk, M., Fernández‐López, R., Parrado‐Gallego, Á., Pachón-Garrudo, V. M., -Royan, J. C., Hevilla, J., Jiménez-Ortega, E., & Leal, A. (2017) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2017.04.035 · Cited by 3
Lowe, G. J., Spottiswoode, B. S., Declerck, J. M., Sullivan, K. R., Sharif, M. S., Wong, W., & Sanghera, B. (2020) · BJR|Open · doi:10.1259/bjro.20190035 · Cited by 3
Gutman, F., Poncin, D., Guedec-Ghelfi, R., Génin, R., David, P.-M., Cuif, A., Popinat, G., Nogueira, V., & Aide, N. (2025) · EJNMMI Reports · doi:10.1186/s41824-025-00253-9 · Cited by 2
Self-citationDo phantom harmonization efforts translate into harmonized patient images?
Panetta, J. V., Scheuermann, J. S., Karp, J. S., & Daube-Witherspoon, M. E. (2015) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2015.7582196 · Cited by 1
Jiménez-Ortega, E., Agüera, R., Ureba, A., Balcerzyk, M., Wals-Zurita, A., Gómez, F. J. G., & Leal, A. (2022) · Tomography · doi:10.3390/tomography8020090 · Cited by 1
Novel biomarkers for melanoma immunotherapy
Wong, N. M. A. (2020) · Minerva Access (University of Melbourne)
Prenosil, G. A., Hentschel, M., Weitzel, T., Sari, H., Shi, K., & Rominger, A. (2021) · Research Square · doi:10.21203/rs.3.rs-864693/v1
Rufini, V., Lorusso, M., Inzani, F. S., Pasciuto, T., Triumbari, E. K. A., Grillo, L. R., Lococo, F., Margaritora, S., Pescarmona, E. O., & Rindi, G. (2022) · Research Square · doi:10.21203/rs.3.rs-1273213/v1
Okazaki, E., Koyama, K., Higashikawa, M., Nishida, N., & Fukuda, H. (2024) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s00405-024-08905-5
Babacan, G. B., Tamam, M. Ö., Demirel, N., Mansuroğlu, İ., & Bilgi, H. (2025) · Nuclear Medicine Communications · doi:10.1097/mnm.0000000000002047
Kupitz, D., Wissel, H., Wuestemann, J., Bluemel, S., Pech, M., Amthauer, H., Kreissl, M. C., & Großer, O. S. (2021) · Figshare · doi:10.6084/m9.figshare.15086222
Kupitz, D., Wissel, H., Wuestemann, J., Bluemel, S., Pech, M., Amthauer, H., Kreissl, M. C., & Großer, O. S. (2021) · Figshare · doi:10.6084/m9.figshare.15086228
Wong, A. N. M., Callahan, J., Keyaerts, M., Neyns, B., Mangana, J., Aberle, S., Herschtal, A., Fullerton, S., Milne, D., Amir, I., et al. (2020) · Figshare · doi:10.6084/m9.figshare.12307817
Self-citationBela Andela, S., Amthauer, H., Furth, C., Rogasch, J. M. M., Beck, M., Mehrhof, F. B., Ghadjar, P., van den Hoff, J., Klatte, T., Tahbaz, R., et al. (2024) · Figshare · doi:10.6084/m9.figshare.26755660
Kupitz, D., Wissel, H., Wuestemann, J., Bluemel, S., Pech, M., Amthauer, H., Kreissl, M. C., & Großer, O. S. (2021) · Figshare · doi:10.6084/m9.figshare.15086225
Jin, S. O., Mérida, I., Stavropoulos, I., Elwes, R. D. C., Lam, T., Guedj, E., Girard, N. J., Costes, N., & Hammers, A. (2024) · Figshare · doi:10.6084/m9.figshare.26640244
Harder, F. N., Jungmann, F., Kaissis, G. A., Lohöfer, F. K., Ziegelmayer, S., Havel, D., Quante, M., Reichert, M., Schmid, R. M., Demir, İ. E., et al. (2021) · Figshare · doi:10.6084/m9.figshare.15071563
Metadata
- Authors
- Quak, E., Le Roux, P.-Y., Hofman, M. S., Robin, P., Bourhis, D., Callahan, J., Binns, D., Desmonts, C., Salaun, P.-Y., Hicks, R. J., & Aide, N.
- Affiliations
- Centre François Baclesse (FR)
- The University of Melbourne (AU)
- Centre Hospitalier Régional Universitaire de Brest (FR)
- Centre Hospitalier Universitaire de Caen Normandie (FR)
- Inserm (FR)
- Corresponding author
- Aide, Nicolas
- ORCID
- Venue
- European Journal of Nuclear Medicine and Molecular Imaging
- Published
- 2015-07-30
- Volume
- 42
- Issue
- 13
- Pages
- 2072-2082
- ISSN
- 1619-7070 (ISSN-L)
- 1619-7089
- PMC
- PMC4623085
- OpenAlex
- W941202616
- Cited by
- 107
- References
- 33
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 7 · 2023: 6 · 2022: 12 · 2021: 16 · 2020: 8 · 2019: 9 · 2018: 12 · 2017: 16 · 2016: 11 · 2015: 4
- FWCI
- 11.62
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- European Journal of Nuclear Medicine and Molecular Imaging (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- HAL (submittedVersion)
- Minerva Access (University of Melbourne) (submittedVersion, cc-by)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Lung Cancer Diagnosis and Treatment
- Keywords
- point spread function reconstruction, time-of-flight PET, SUVmax, SUVpeak, EANM guidelines, standardized uptake value, multicentre validation
- MeSH terms
- Aged, Carcinoma, Non-Small-Cell Lung, Female, Humans, Image Processing, Computer-Assisted, Liver Neoplasms, Lymphoma, Non-Hodgkin, Male, Melanoma, Middle Aged, Radiopharmaceuticals, Fluorodeoxyglucose F18, Positron-Emission Tomography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review