The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
The EANM practice guidelines for bone scintigraphy
Open accessAbstract
PURPOSE: The radionuclide bone scan is the cornerstone of skeletal nuclear medicine imaging. Bone scintigraphy is a highly sensitive diagnostic nuclear medicine imaging technique that uses a radiotracer to evaluate the distribution of active bone formation in the skeleton related to malignant and benign disease, as well as physiological processes. METHODS: The European Association of Nuclear Medicine (EANM) has written and approved these guidelines to promote the use of nuclear medicine procedures of high quality. CONCLUSION: The present guidelines offer assistance to nuclear medicine practitioners in optimizing the diagnostic procedure and interpreting bone scintigraphy. These guidelines describe the protocols that are currently accepted and used routinely, but do not include all existing procedures. They should therefore not be taken as exclusive of other nuclear medicine modalities that can be used to obtain comparable results. It is important to remember that the resources and facilities available for patient care may vary.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Scher, H. I., Halabi, S., Tannock, I., Morris, M., Sternberg, C. N., Carducci, M. A., Eisenberger, M. A., Higano, C., Bubley, G. J., Dreicer, R., et al. (2008) · Journal of Clinical Oncology · doi:10.1200/jco.2007.12.4487 · Cited by 2,241
Effective Doses in Radiology and Diagnostic Nuclear Medicine: A Catalog
Mettler, F. A., Huda, W., Yoshizumi, T. T., & Mahesh, M. (2008) · Radiology · doi:10.1148/radiol.2481071451 · Cited by 2,008
EANM/SNMMI Guideline for18F-FDG Use in Inflammation and Infection
Jamar, F., Buscombe, J., Chiti, A., Christian, P. E., Delbeke, D., Donohoe, K. J., Israel, O., Martin-Comin, J., & Signore, A. (2013) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.112524 · Cited by 577
(1991) · Annals of the ICRP · doi:10.1016/0146-6453(91)90017-b · Cited by 565
Cook, G. J., Houston, S., Rubens, R., Maisey, M. N., & Fogelman, I. (1998) · Journal of Clinical Oncology · doi:10.1200/jco.1998.16.10.3375 · Cited by 562
Dieppe, P., Cushnaghan, J., Young, P., & Kirwan, J. (1993) · Annals of the Rheumatic Diseases · doi:10.1136/ard.52.8.557 · Cited by 430
(2008) · Annals of the ICRP · doi:10.1016/j.icrp.2008.08.003 · Cited by 390
Franzius, C., Sciuk, J., Daldrup-Link, H. E., Jürgens, H., & Schober, O. (2000) · European Journal of Nuclear Medicine · doi:10.1007/s002590000301 · Cited by 291
Schirrmeister, H., Glatting, G., Hetzel, J., Nüssle, K., Arslandemir, C., Buck, A. K., Dziuk, K., Gabelmann, A., Reske, S. N., & Hetzel, M. (2001) · PubMed · Cited by 257
Ryan, C. J., Shah, S., Efstathiou, E., Smith, M. R., Taplin, M.-E., Bubley, G. J., Logothetis, C. J., Kheoh, T., Kilian, C., Haqq, C. M., et al. (2011) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-11-0815 · Cited by 219
Palmedo, H., Marx, C., Ebert, A., Kreft, B., Ko, Y., Türler, A., Vorreuther, R., Göhring, U., Schild, H. H., Gerhardt, T., et al. (2014) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-013-2532-6 · Cited by 196
Gallowitsch, H.-J., Kresnik, E., Gasser, J., Kumnig, G., Igerc, I., Mikosch, P., & Lind, P. (2003) · Investigative Radiology · doi:10.1097/01.rli.0000063983.86229.f2 · Cited by 170
18F-NaF PET/CT: EANM procedure guidelines for bone imaging
Beheshti, M., Mottaghy, F. M., Payche, F., Behrendt, F. F. F., Van den Wyngaert, T., Fogelman, I., Strobel, K., Celli, M., Fanti, S., Giammarile, F., et al. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-015-3138-y · Cited by 167
Self-citationFor the EANM/SNMMI Paediatric Dosage Harmonization Working Group, Laßmann, M., & Treves, S. T. (2014) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-014-2731-9 · Cited by 158
Radionuclide and Hybrid Bone Imaging
Fogelman, I., Wall, H., & Gnanasegaran, G. (2012) · Springer eBooks · doi:10.1007/978-3-642-02400-9 · Cited by 155
Self-citationComparison of FDG PET and SPECT for Detection of Bone Metastases in Breast Cancer
Uematsu, T., Yuen, S., Yukisawa, S., Aramaki, T., Morimoto, N., Endo, M., Furukawa, H., Uchida, Y., & Watanabe, J. (2005) · American Journal of Roentgenology · doi:10.2214/ajr.184.4.01841266 · Cited by 141
Laßmann, M., & Treves, S. T. (2014) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-014-2817-4 · Cited by 125
Routine quality control recommendations for nuclear medicine instrumentation
Sokole, E. B., With contribution from the EANM Working Group on Nuclear Medicine Instrumentation Quality Control:, Płachcińska, A., Britten, A. J., Georgosopoulou, M. L., Tindale, W., & Klett, R. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-009-1347-y · Cited by 124
Quantification of 99mTc-DPD concentration in the lumbar spine with SPECT/CT
Cachovan, M., Vija, A. H., Joachim Hornegger, A., & Kuwert, T. (2013) · EJNMMI Research · doi:10.1186/2191-219x-3-45 · Cited by 123
Self-citationProcedure Guideline for SPECT/CT Imaging 1.0.
Delbeke, D., Coleman, R. E., Guiberteau, M. J., Brown, M. L., Royal, H. D., Siegel, B. A., Townsend, D. W., Berland, L. L., Parker, J. A., Zubal, G. I., et al. (2006) · PubMed · Cited by 95
Breast scintigraphy: procedure guidelines for tumour imaging
Bombardieri, E., Aktolun, C., Baum, R. P., Bishof-Delaloye, A., Buscombe, J. R., Chatal, J. F., Maffioli, L. S., Moncayo, R., Mortelmans, L., & Reske, S. N. (2003) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-003-1354-3 · Cited by 90
Bone scintigraphy: procedure guidelines for tumour imaging
Bombardieri, E., Aktolun, C., Baum, R. P., Bishof-Delaloye, A., Buscombe, J. R., Chatal, J. F., Maffioli, L. S., Moncayo, R., Mortelmans, L., & Reske, S. N. (2003) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-003-1347-2 · Cited by 68
Bone scintigraphy and metabolic disorders.
Mari, C., Catafau, A., & Carrió, I. (1999) · PubMed · Cited by 46
Nuclear Medicine Studies in Metabolic Bone Disease
Hain, S. F., & Fogelman, I. (2002) · Seminars in Musculoskeletal Radiology · doi:10.1055/s-2002-36731 · Cited by 46
Huellner, M. W., Bürkert, A., Strobel, K., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0085359 · Cited by 30
Self-citationBone Densitometry: Science and Practice
Blake, G. M., & Fogelman, I. (2012) · Springer eBooks · doi:10.1007/978-3-642-02400-9_38 · Cited by 27
Correction to: 18F-NaF PET/CT: EANM procedure guidelines for bone imaging
Beheshti, M., Mottaghy, F. M., Paycha, F., Behrendt, F. F., WYNGAERT, T. V. D., Fogelman, I., Strobel, K., Celli, M., Fanti, S., Giammarile, F., et al. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-017-3874-2 · Cited by 10
Self-citation
Cited by
Screening for Transthyretin Amyloid Cardiomyopathy in Everyday Practice
Witteles, R. M., Bokhari, S., Damy, T., Elliott, P. M., Falk, R. H., Fine, N. M., Gospodinova, M., Obici, L., Rapezzi, C., & Garcia-Pavia, P. (2019) · JACC: Heart Failure · doi:10.1016/j.jchf.2019.04.010 · Cited by 351
The Dual-Tree Complex Wavelet Transform: A New Efficient Tool For Image Restoration And Enhancement
Kingsbury, N. (1998) · doi:10.5281/zenodo.36900 · Cited by 272
Metadata
- Authors
- On behalf of the EANM Bone & Joint Committee and the Oncology Committee., Van den Wyngaert, T., Strobel, K., Kampen, W. U., Kuwert, T., van der Bruggen, W., Mohan, H. K., Gnanasegaran, G., Delgado-Bolton, R., Weber, W. A., Beheshti, M., Langsteger, W., Giammarile, F., Mottaghy, F. M., & Paycha, F.
- Venue
- European Journal of Nuclear Medicine and Molecular Imaging
- Published
- 2016-06-04
- Volume
- 43
- Issue
- 9
- Pages
- 1723-1738
- ISSN
- 1619-7070 (ISSN-L)
- 1619-7089
- OpenAlex
- W2415720263
- Cited by
- 448
- References
- 27
- FWCI
- 23.13
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.