CoChat

Dual tracer tau PET imaging reveals different molecular targets for 11C-THK5351 and 11C-PBB3 in the Alzheimer brain

Open access
Chiotis, Konstantinos, Stenkrona, Per, Almkvist, Ove, Stepanov, Vladimir, Ferreira, Daniel, Arakawa, Ryosuke, Takano, Akihiro, Westman, Eric, Varrone, Andrea, Okamura, Nobuyuki, Shimada, Hitoshi, Higuchi, Makoto, Halldin, Christer, Nordberg, Agneta · 2018 · European Journal of Nuclear Medicine and Molecular Imaging
Cited by 41

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

Several tau PET tracers have been developed, but it remains unclear whether they bind to the same molecular target on the heterogeneous tau pathology. In this study we evaluated the binding of two chemically different tau-specific PET tracers ( 11 C-THK5351 and 11 C-PBB3) in a head-to-head, in vivo, multimodal design. Nine patients with a diagnosis of mild cognitive impairment or probable Alzheimer’s disease and cerebrospinal fluid biomarker evidence supportive of the presence of Alzheimer’s disease brain pathology were recruited after thorough clinical assessment. All patients underwent imaging with the tau-specific PET tracers 11 C-THK5351 and 11 C-PBB3 on the same day, as well as imaging with the amyloid-beta-specific tracer 11 C-AZD2184, a T1-MRI sequence, and neuropsychological assessment. The load and regional distribution of binding differed between 11 C-THK5351 and 11 C-PBB3 with no statistically significant regional correlations observed between the tracers. The binding pattern of 11 C-PBB3, but not that of 11 C-THK5351, in the temporal lobe resembled that of 11 C-AZD2184, with strong correlations detected between 11 C-PBB3 and 11 C-AZD2184 in the temporal and occipital lobes. Global cognition correlated more closely with 11 C-THK5351 than with 11 C-PBB3 binding. Similarly, cerebrospinal fluid tau measures and entorhinal cortex thickness were more closely correlated with 11 C-THK5351 than with 11 C-PBB3 binding. This research suggests different molecular targets for these tracers; while 11 C-PBB3 appeared to preferentially bind to tau deposits with a close spatial relationship to amyloid-beta, the binding pattern of 11 C-THK5351 fitted the expected distribution of tau pathology in Alzheimer’s disease better and was more closely related to downstream disease markers.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00259-018-4012-5

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

Metadata

Authors
Chiotis, K., Stenkrona, P., Almkvist, O., Stepanov, V., Ferreira, D., Arakawa, R., Takano, A., Westman, E., Varrone, A., Okamura, N., Shimada, H., Higuchi, M., Halldin, C., & Nordberg, A.
Venue
European Journal of Nuclear Medicine and Molecular Imaging
Published
2018-05-12
Volume
45
Issue
9
Pages
1605-1617
ISSN
  • 1619-7070 (ISSN-L)
  • 1619-7089
OpenAlex
W2801345007
Cited by
41
References
16
FWCI
4.31
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.