The DOI matches its Crossref record.
Clinical indications, image acquisition and data interpretation for white blood cells and anti-granulocyte monoclonal antibody scintigraphy: an EANM procedural guideline
Open accessAbstract
INTRODUCTION: Radiolabelled autologous white blood cells (WBC) scintigraphy is being standardized all over the world to ensure high quality, specificity and reproducibility. Similarly, in many European countries radiolabelled anti-granulocyte antibodies (anti-G-mAb) are used instead of WBC with high diagnostic accuracy. The EANM Inflammation & Infection Committee is deeply involved in this process of standardization as a primary goal of the group. AIM: The main aim of this guideline is to support and promote good clinical practice despite the complex environment of a national health care system with its ethical, economic and legal aspects that must also be taken into consideration. METHOD: After the standardization of the WBC labelling procedure (already published), a group of experts from the EANM Infection & Inflammation Committee developed and validated these guidelines based on published evidences. RESULTS: Here we describe image acquisition protocols, image display procedures and image analyses as well as image interpretation criteria for the use of radiolabelled WBC and monoclonal antigranulocyte antibodies. Clinical application for WBC and anti-G-mAb scintigraphy is also described. CONCLUSIONS: These guidelines should be applied by all nuclear medicine centers in favor of a highly reproducible standardized practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The EBJIS definition of periprosthetic joint infection: a practical guide for clinicians
McNally, M., Sousa, R., Wouthuyzen-Bakker, M., Chen, A. F., Soriano, A., Vogely, H. C., Clauss, M., Higuera, C. A., & Trebše, R. (2021) · The Bone & Joint Journal · doi:10.1302/0301-620x.103b1.bjj-2020-1381.r1 · Cited by 797
Chakfé, N., Diener, H., Lejay, A., Assadian, O., Berard, X., Caillon, J., Fourneau, I., Glaudemans, A. W. J. M., Koncar, I., Lindholt, J., et al. (2020) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2019.10.016 · Cited by 563
Calabria, F., Leporace, M., Tavolaro, R., & Bagnato, A. (2023) · Radiology‐Nuclear Medicine Diagnostic Imaging · doi:10.1002/9781119603627.ch4 · Cited by 3
Metadata
- Authors
- Signore, A., Jamar, F., Israel, O., Buscombe, J., Martin-Comin, J., & Lazzeri, E.
- Venue
- European Journal of Nuclear Medicine and Molecular Imaging
- Published
- 2018-05-31
- Volume
- 45
- Issue
- 10
- Pages
- 1816-1831
- ISSN
- 1619-7070 (ISSN-L)
- 1619-7089
- OpenAlex
- W2806696849
- Cited by
- 190
- References
- 0
- FWCI
- 14.17
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinical indications, image acquisition and data interpretation for white blood cells and anti-granulocyte monoclonal antibody scintigraphy: an EANM procedural guideline. https://app.cochat.ai/papers/10.1007/s00259-018-4052-x
- The paper
- Signore, A., Jamar, F., Israel, O., Buscombe, J., Martin-Comin, J., & Lazzeri, E. (2018). Clinical indications, image acquisition and data interpretation for white blood cells and anti-granulocyte monoclonal antibody scintigraphy: an EANM procedural guideline. European Journal of Nuclear Medicine and Molecular Imaging. https://doi.org/10.1007/s00259-018-4052-x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.