CoChat

PET/MRI versus PET/CT in oncology: a prospective single-center study of 330 examinations focusing on implications for patient management and cost considerations

Open access
Mayerhoefer, Marius E., Prosch, Helmut, Beer, Lucian, Tamandl, Dietmar, Beyer, Thomas, Hoeller, Christoph, Berzaczy, Dominik, Raderer, Markus, Preusser, Matthias, Hochmair, Maximilian, Kiesewetter, Barbara, Scheuba, Christian, Ba-Ssalamah, Ahmed, Karanikas, Georgios, Kesselbacher, Julia, Prager, Gerald, Dieckmann, Karin, Polterauer, Stephan, Weber, Michael, Rausch, Ivo, Brauner, Bernhard, Eidherr, Harald, Wadsak, Wolfgang, Haug, Alexander R. · 2020 · European Journal of Nuclear Medicine and Molecular Imaging
Cited by 160

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

PURPOSE: PET/MRI has recently been introduced into clinical practice. We prospectively investigated the clinical impact of PET/MRI compared with PET/CT, in a mixed population of cancer patients, and performed an economic evaluation of PET/MRI. METHODS: F]FDOPA, depending on tumor histology. PET/MRI and PET/CT were rated separately, and lesions were assessed per anatomic region; based on regions, per-examination and per-patient accuracies were determined. A simulated, multidisciplinary team meeting served as reference standard and determined whether differences between PET/CT and PET/MRI affected patient management. The McNemar tests were used to compare accuracies, and incremental cost-effectiveness ratios (ICERs) for PET/MRI were calculated. RESULTS: Two hundred sixty-three patients (330 same-day PET/CT and PET/MRI examinations) were included. PET/MRI was accurate in 319/330 examinations and PET/CT in 277/330 examinations; the respective accuracies of 97.3% and 83.9% differed significantly (P < 0.001). The additional findings on PET/MRI-mainly liver and brain metastases-had implications for patient management in 21/263 patients (8.0%). The per-examination cost was 596.97 EUR for PET/MRI and 405.95 EUR for PET/CT. ICERs for PET/MRI were 14.26 EUR per percent of diagnostic accuracy and 23.88 EUR per percent of correctly managed patients. CONCLUSIONS: PET/MRI enables more appropriate management than PET/CT in a nonnegligible fraction of cancer patients. Since the per-examination cost is about 50% higher for PET/MRI than for PET/CT, a histology-based triage of patients to either PET/MRI or PET/CT may be meaningful.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00259-019-04452-y

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 160

Metadata

Authors
Mayerhoefer, M. E., Prosch, H., Beer, L., Tamandl, D., Beyer, T., Hoeller, C., Berzaczy, D., Raderer, M., Preusser, M., Hochmair, M., Kiesewetter, B., Scheuba, C., Ba-Ssalamah, A., Karanikas, G., Kesselbacher, J., Prager, G., Dieckmann, K., Polterauer, S., Weber, M., Rausch, I., Brauner, B., Eidherr, H., Wadsak, W., & Haug, A. R.
Venue
European Journal of Nuclear Medicine and Molecular Imaging
Published
2019-08-13
Volume
47
Issue
1
Pages
51-60
ISSN
  • 1619-7070 (ISSN-L)
  • 1619-7089
OpenAlex
W2968041467
Cited by
160
References
1
FWCI
11.25
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.