CoChat

Three dimensionalCT analysis of femoral tunnel position after ACL reconstruction. A prospective study of one hundred and thirty five cases

Reynaud, Olivier, Batailler, Cécile, Lording, Timothy, Lustig, Sebastien, Servien, Elvire, Neyret, Philippe · 2017 · International Orthopaedics

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Abstract

Background One of the principal causes for failure of anterior cruciate ligament reconstruction (ACL) is femoral tunnel mal-position. Several studies compare the position of femoral tunnels achieved with various techniques, with small series and using a quadrant assessment method. Questions (1) What is the incidence of anatomical positioning of the intra-articular femoral tunnel aperture in primary ACL reconstruction in a university knee surgery? (2) What are the main errors in positioning? Methods 3D-CT scans were performed after primary ACL reconstruction in 135 consecutive cases. The intra-articular position of the femoral tunnel aperture was analyzed using the Magnussen classification. Results The intra-articular tunnel position was deemed anatomical in 77%, intermediate in 20.8%, and non-anatomical in 2.2%. Among the mal-positioned tunnels, 54.8% were vertical, 29% were anteriorly positioned, and 16.1% were both. Conclusions The intra articular femoral tunnel aperture was well positioned using an outside-in technique. The main error of tunnel positioning was a tunnel too vertical. Level of evidence Level III, prospective study (case series).

Overview

Integrity signals

Registry

Crossref · 10.1007/s00264-017-3596-x

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 1

  1. Sbihi A, Christel P (2006) Anatomie du ligament croisé antérieur et isométrie. In: Franck A, Dorfmann H, d’arthroscopie Sf (eds) Arthroscopie: Généralités, genou, cheville, hanche, épaule, coude, poignet, extra-articulaire, 2ème edn. Elsevier, Amsterdam, pp 125–135

Cited by

See all 11

Metadata

Authors
Reynaud, O., Batailler, C., Lording, T., Lustig, S., Servien, E., & Neyret, P.
Affiliations
  • Hôpital de la Croix-Rousse (FR)
  • Lyon Genou Centre Albert Trillat (FR)
Corresponding author
  • Reynaud, Olivier
  • Batailler, Cécile
  • Lording, Timothy
  • Neyret, Philippe
Venue
International Orthopaedics
Published
2017-08-14
Volume
41
Issue
11
Pages
2313-2319
ISSN
  • 0341-2695 (ISSN-L)
  • 1432-5195
OpenAlex
W2745421200
Cited by
11
References
29
Citations by year
2026: 1 · 2024: 1 · 2023: 1 · 2022: 1 · 2021: 2 · 2020: 1 · 2019: 1 · 2018: 3
FWCI
1.40
Type
journal article
Language
en
Open access
closed
Locations
  • International Orthopaedics (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Surgery › Knee injuries and reconstruction techniques
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Foot and Ankle Surgery
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Elbow and Forearm Trauma Treatment
Keywords
anterior cruciate ligament reconstruction, femoral tunnel placement, outside-in technique, primary ACL reconstruction, reconstruction failure
MeSH terms
Anterior Cruciate Ligament Injuries, Adult, Female, Femur, Humans, Male, Prospective Studies, Tomography, X-Ray Computed, Anterior Cruciate Ligament, Imaging, Three-Dimensional, Anterior Cruciate Ligament Reconstruction

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.