CoChat

The efficacy of immersive virtual reality surgical simulator training for pedicle screw placement: a randomized double-blind controlled trial

Xin, Baoquan, Huang, Xing, Wan, Wei, Lv, Kai, Hu, Yiwei, Wang, Jing, Li, Song, Zou, Weiwei, Xiao, Jianru, Liu, Tielong · 2020 · International Orthopaedics

The DOI matches its Crossref record; 44 of the 45 references it cites were found in a registry or an index.

Abstract

Objective To verify whether the pedicle screw placement (PSP) skills of young surgeons receiving immersive virtual reality surgical simulator (IVRSS) training could be improved effectively and whether the IVRSS-PSP training mode could produce a real clinical value in clinical surgery.Methods Twenty-four young surgeons were equally randomized to a VR group and a NON-VR group. Participants in VR group received IVRSS-PSP training, and those in NON-VR group used the conventional model of observing a spinal model first and then watching a teaching video of spinal surgery for 40 minutes x five. The nailing outcome of the participants before and after training was evaluated by statistical analysis in both groups.Results Post-training data analysis showed that the success rate and accuracy rate of screw placement in VR group and NON-VR group were 82.9% and 69.6% vs. 74.2% and 55.4%, respectively, showing statistically significant differences between the two groups by chi-square test (P < 0.05).Conclusion The present study demonstrated that IVRSS-PSP was helpful to improve the success rate of PSP for young surgeons, and may provide valuable reference for PSP training of young surgeons. In addition, our study also showed a promising potential of the VR technology in surgical simulation training.

Overview

Integrity signals

Registry

Crossref · 10.1007/s00264-020-04488-y

Cites

44 of 44 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 44 references

Cited by

See all 62

Metadata

Authors
Xin, B., Huang, X., Wan, W., Lv, K., Hu, Y., Wang, J., Li, S., Zou, W., Xiao, J., & Liu, T.
Affiliations
  • Shandong First Medical University (CN)
  • Second Military Medical University (CN)
  • Anhui University of Traditional Chinese Medicine (CN)
Corresponding author
  • Zou, Weiwei
  • Xiao, Jianru
  • Liu, Tielong
Venue
International Orthopaedics
Published
2020-02-12
Volume
44
Issue
5
Pages
927-934
ISSN
  • 0341-2695 (ISSN-L)
  • 1432-5195
OpenAlex
W3006110865
Cited by
58
References
45
Citations by year
2026: 3 · 2025: 7 · 2024: 9 · 2023: 9 · 2022: 7 · 2021: 8 · 2020: 12
FWCI
8.22
Type
journal article
Language
en
Open access
closed
Licence
Locations
  • International Orthopaedics (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Surgery › Surgical Simulation and Training
  • Health Sciences › Medicine › Surgery › Spinal Fractures and Fixation Techniques
  • Physical Sciences › Engineering › Biomedical Engineering › Anatomy and Medical Technology
Keywords
pedicle screw placement, immersive virtual reality, surgical simulator training, spinal surgery, surgical skill acquisition, young surgeons, screw placement accuracy, surgical training
MeSH terms
Simulation Training, Virtual Reality, Clinical Competence, Humans, Internship and Residency, Pedicle Screws

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The efficacy of immersive virtual reality surgical simulator training for pedicle screw placement: a randomized double-blind controlled trial. https://app.cochat.ai/papers/10.1007/s00264-020-04488-y
The paper
Xin, B., Huang, X., Wan, W., Lv, K., Hu, Y., Wang, J., Li, S., Zou, W., Xiao, J., & Liu, T. (2020). The efficacy of immersive virtual reality surgical simulator training for pedicle screw placement: a randomized double-blind controlled trial. International Orthopaedics. https://doi.org/10.1007/s00264-020-04488-y

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.