Parathyroid Four‐Dimensional Computed Tomography: Evaluation of Radiation Dose Exposure During Preoperative Localization of Parathyroid Tumors in Primary Hyperparathyroidism
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Background: Parathyroid four‐dimensional computed tomography (4DCT) provides greater sensitivity than sestamibi with single photon emission CT (SPECT, or SeS) for preoperative localization of parathyroid tumors in patients with primary hyperparathyroidism (PHPT). The radiation dose imparted to the patient during preoperative parathyroid imaging, however, has not been analyzed. Methods: Patients with biochemically unequivocal PHPT referred for minimally invasive parathyroidectomy underwent 4DCT or SeS. 4DCT was performed using a 64 detector row CT scanner, and SeS used a standardized protocol of 20 mCi of technetium‐99m followed by planar and SPECT imaging. The CT radiation dose was estimated using the Imaging Performance Assessment of CT Scanners (ImPACT) calculator, and the SeS dose was estimated using the US Nuclear Regulatory Commission Regulation (NUREG) method. Results: The calculated effective doses of 4DCT and SeS were 10.4 and 7.8 mSv, respectively, in contrast to an estimated annual background radiation exposure of approximately 3 mSv. The dose to the thyroid with 4DCT, however, was about 57 times higher (92.0 vs. 1.6 mGy) than that with SeS. Based on age‐ and sex‐dependent risk factors, the calculated risk of 4DCT‐related thyroid cancer developing in a 20 year old woman was 1,040/million (i.e., about 0.1%). Conclusions: 4DCT, a superior preoperative imaging modality for locating parathyroid tumors, imparts a significantly higher thyroid radiation dose than SeS. Given the enhanced risk of thyroid cancer in individuals with radiation exposure at a young age, 4DCT should be used judiciously in young PHPT patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CANCER RISKS FROM MEDICAL RADIATION
Ron, E. (2003) · Health Physics · doi:10.1097/00004032-200307000-00011 · Cited by 382 · cited 1×
“2 mSv in the United States [14].”
Lavely, W. C., Goetze, S., Friedman, K. P., Leal, J. P., Zhang, Z., Garret-Mayer, E., Dackiw, A. P. B., Tufano, R. P., Zeiger, M. A., & Ziessman, H. A. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.040428 · Cited by 349
Imaging for primary hyperparathyroidism—an evidence-based analysis
Mihai, R., Simon, D., & Hellman, P. (2009) · Langenbeck's Archives of Surgery · doi:10.1007/s00423-009-0534-4 · Cited by 160 · cited 8×
“Methods Patients with biochemically unequivocal PHPT referred for minimally invasive parathyroidectomy underwent 4DCT or SeS.”
BackgroundInfluentialMazonakis, M., Tzedakis, A., Damilakis, J. E., & Gourtsoyiannis, N. (2006) · European Radiology · doi:10.1007/s00330-006-0417-9 · Cited by 145 · cited 1×
“This is also supported by the findings that regular neck CT in children may result in an increased risk of developing thyroid malignancies in up to 390 per million patients [20].”
ResultLong-term risks for thyroid cancer and other neoplasms after exposure to radiation
Schneider, A. B., & Sarne, D. H. (2005) · Nature Clinical Practice Endocrinology & Metabolism · doi:10.1038/ncpendmet0022 · Cited by 116 · cited 1×
“Relative risk is also linearly related to the exposure dose, starting as low as 10 cGy and increasing up to at least 30 Gy [19].”
Background
Metadata
- Authors
- Mahajan, A., Starker, L. F., Ghita, M., Udelsman, R., Brink, J. A., & Carling, T.
- Venue
- World Journal of Surgery
- Publisher
- Wiley
- Published
- 2011-12-07
- Volume
- 36
- Issue
- 6
- Pages
- 1335-1339
- ISSN
- 0364-2313 (ISSN-L)
- 1432-2323
- OpenAlex
- W2013076632
- Cited by
- 164
- References
- 5
- FWCI
- 5.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.