Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 471

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Portal Vein Embolization Before Liver Resection: A Systematic Review

Open access
van Lienden, K. P., van den Esschert, J. W., de Graaf, W., Bipat, S., Lameris, J. S., van Gulik, T. M., van Delden, O. M.·2013·CardioVascular and Interventional Radiology

Abstract

PURPOSE: This is a review of literature on the indications, technique, and outcome of portal vein embolization (PVE). METHODS: A systematic literature search on outcome of PVE from 1990 to 2011 was performed in Medline, Cochrane, and Embase databases. RESULTS: Forty-four articles were selected, including 1,791 patients with a mean age of 61 ± 4.1 years. Overall technical success rate was 99.3 %. The mean hypertrophy rate of the FRL after PVE was 37.9 ± 0.1 %. In 70 patients (3.9 %), surgery was not performed because of failure of PVE (clinical success rate 96.1 %). In 51 patients (2.8 %), the hypertrophy response was insufficient to perform liver resection. In the other 17 cases, 12 did not technically succeed (0.7 %) and 7 caused a complication leading to unresectability (0.4 %). In 6.1 %, resection was cancelled because of local tumor progression after PVE. Major complications were seen in 2.5 %, and the mortality rate was 0.1 %. A head-to-head comparison shows a negative effect of liver cirrhosis on hypertrophy response. The use of n-butyl cyanoacrylate seems to have a greater effect on hypertrophy, but the difference with other embolization materials did not reach statistical significance. No difference in regeneration is seen in patients with cholestasis or chemotherapy. CONCLUSIONS: Preoperative PVE has a high technical and clinical success rate. Liver cirrhosis has a negative effect on regeneration, but cholestasis and chemotherapy do not seem to have an influence on the hypertrophy response. The use of n-butyl cyanoacrylate may result in a greater hypertrophy response compared with other embolization materials used.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00270-012-0440-y

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 34 references

Cited by

See all 471

Metadata

Authors
van Lienden, K. P., van den Esschert, J. W., de Graaf, W., Bipat, S., Lameris, J. S., van Gulik, T. M., & van Delden, O. M.
Venue
CardioVascular and Interventional Radiology
Published
2012-07-18
Volume
36
Issue
1
Pages
25-34
ISSN
  • 0174-1551 (ISSN-L)
  • 1432-086X
OpenAlex
W2159241159
Cited by
471
References
34
FWCI
2.90
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Portal Vein Embolization Before Liver Resection: A Systematic Review. https://app.cochat.ai/papers/10.1007/s00270-012-0440-y
The paper
van Lienden, K. P., van den Esschert, J. W., de Graaf, W., Bipat, S., Lameris, J. S., van Gulik, T. M., & van Delden, O. M. (2013). Portal Vein Embolization Before Liver Resection: A Systematic Review. CardioVascular and Interventional Radiology. https://doi.org/10.1007/s00270-012-0440-y

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.