The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control
Open accessAbstract
The aim of this study was to assess the diagnostic accuracy of dual-source computed tomography (DSCT) for evaluation of coronary artery disease (CAD) in a population with extensive coronary calcifications without heart rate control. Thirty patients (24 male, 6 female, mean age 63.1+/-11.3 years) with a high pre-test probability of CAD underwent DSCT coronary angiography and invasive coronary angiography (ICA) within 14+/-9 days. No beta-blockers were administered prior to the scan. Two readers independently assessed image quality of all coronary segments with a diameter > or =1.5 mm using a four-point score (1: excellent to 4: not assessable) and qualitatively assessed significant stenoses as narrowing of the luminal diameter >50%. Causes of false-positive (FP) and false-negative (FN) ratings were assigned to calcifications or motion artifacts. ICA was considered the standard of reference. Mean body mass index was 28.3+/-3.9 kg/m2 (range 22.4-36.3 kg/m2), mean heart rate during CT was 70.3+/-14.2 bpm (range 47-102 bpm), and mean Agatston score was 821+/-904 (range 0-3,110). Image quality was diagnostic (scores 1-3) in 98.6% (414/420) of segments (mean image quality score 1.68+/-0.75); six segments in three patients were considered not assessable (1.4%). DSCT correctly identified 54 of 56 significant coronary stenoses. Severe calcifications accounted for false ratings in nine segments (eight FP/one FN) and motion artifacts in two segments (one FP/one FN). Overall sensitivity, specificity, positive and negative predictive value for evaluating CAD were 96.4, 97.5, 85.7, and 99.4%, respectively. First experience indicates that DSCT coronary angiography provides high diagnostic accuracy for assessment of CAD in a high pre-test probability population with extensive coronary calcifications and without heart rate control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
Austen, W., Edwards, J., Frye, R., Gensini, G., Gott, V., Griffith, L., McGoon, D., Murphy, M., & Roe, B. (1975) · Circulation · doi:10.1161/01.cir.51.4.5 · Cited by 3,256
Diagnostic Accuracy of Noninvasive Coronary Angiography Using 64-Slice Spiral Computed Tomography
Raff, G. L., Gallagher, M. J., O’Neill, W. W., & Goldstein, J. A. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.05.056 · Cited by 1,472
First performance evaluation of a dual-source CT (DSCT) system
Flohr, T. G., McCollough, C. H., Bruder, H., Petersilka, M., Gruber, K., Süβ, C., Grasruck, M., Stierstorfer, K., Krauss, B., Raupach, R., et al. (2006) · European Radiology · doi:10.1007/s00330-005-2919-2 · Cited by 1,413
Authors/Task Force Members (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl001 · Cited by 1,336
Quantification of Obstructive and Nonobstructive Coronary Lesions by 64-Slice Computed Tomography
Leber, A. W., Knez, A., von Ziegler, F., Becker, A., Nikolaou, K., Paul, S., Wintersperger, B., Reiser, M., Becker, C. R., Steinbeck, G., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.03.071 · Cited by 1,109
Mollet, N. R., Cademartiri, F., van Mieghem, C. A. G., Runza, G., McFadden, E. P., Baks, T., Serruys, P. W., Krestin, G. P., & de Feyter, P. J. (2005) · Circulation · doi:10.1161/circulationaha.105.533471 · Cited by 1,018
Accuracy of MSCT coronary angiography with 64-slice technology: first experience
Leschka, S., Alkadhi, H., Plass, A., Desbiolles, L., Grünenfelder, J., Marincek, B., & Wildermuth, S. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi261 · Cited by 960
Self-citationRopers, D., Baum, U., Pohle, K., Anders, K., Ulzheimer, S., Ohnesorge, B., Schlundt, C., Bautz, W., Daniel, W. G., & Achenbach, S. (2003) · Circulation · doi:10.1161/01.cir.0000055738.31551.a9 · Cited by 930
Jakobs, T. F., Becker, C. R., Ohnesorge, B., Flohr, T., Suess, C., Schoepf, U. J., & Reiser, M. F. (2002) · European Radiology · doi:10.1007/s00330-001-1278-x · Cited by 615
Hoff, J. A., Chomka, E. V., Krainik, A. J., Daviglus, M., Rich, S., & Kondos, G. T. (2001) · The American Journal of Cardiology · doi:10.1016/s0002-9149(01)01548-x · Cited by 426
Multislice spiral computed tomography coronary angiography in patients with stable angina pectoris
Mollet, N. R., Cademartiri, F., Nieman, K., Saia, F., Lemos, P. A., McFadden, E. P., Pattynama, P. M. T., Serruys, P. W., Krestin, G. P., & de Feyter, P. J. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.03.032 · Cited by 406
Multi–Detector Row CT Systems and Image-Reconstruction Techniques
Flohr, T. G., Schaller, S., Stierstorfer, K., Bruder, H., Ohnesorge, B. M., & Schoepf, U. J. (2005) · Radiology · doi:10.1148/radiol.2353040037 · Cited by 381
Kuettner, A., Trabold, T., Schroeder, S., Feyer, A., Beck, T., Brueckner, A., Heuschmid, M., Burgstahler, C., Kopp, A. F., & Claussen, C. D. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.05.079 · Cited by 280
Morise, A. P., Haddad, W. J., & Beckner, D. (1997) · The American Journal of Medicine · doi:10.1016/s0002-9343(97)00086-7 · Cited by 277
Kuettner, A., Kopp, A. F., Schroeder, S., Rieger, T., Brunn, J., Meisner, C., Heuschmid, M., Trabold, T., Burgstahler, C., Martensen, J., et al. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.05.015 · Cited by 228
Wintersperger, B. J., Nikolaou, K., von Ziegler, F., Johnson, T. R. C., Rist, C., Leber, A. W., Flohr, T. G., Knez, A., Reiser, M. F., & Becker, C. R. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000202639.99949.c6 · Cited by 194
Gilard, M., Cornily, J., Pennec, P.-Y., Joret, C., Gal, G. L., Mansourati, J., Blanc, J., & Boschat, J. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.11.085 · Cited by 148
Optimal image reconstruction intervals for non-invasive coronary angiography with 64-slice CT
Leschka, S., Husmann, L., Desbiolles, L. M., Gaemperli, O., Schepis, T., Koepfli, P., Boehm, T., Marinček, B., Kaufmann, P. A., & Alkadhi, H. (2006) · European Radiology · doi:10.1007/s00330-006-0262-x · Cited by 117
Self-citationGuidelines on the management of stable angina pectoris
Skalidis, E. I., & Vardas, P. E. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl257 · Cited by 80
Cited by
Material differentiation by dual energy CT: initial experience
Johnson, T. R. C., Krauß, B., Sedlmair, M., Grasruck, M., Bruder, H., Morhard, D., Fink, C., Weckbach, S., Lenhard, M., Schmidt, B., et al. (2007) · European Radiology · doi:10.1007/s00330-006-0517-6 · Cited by 1,510
Abbara, S., Arbab-Zadeh, A., Callister, T. Q., Desai, M. Y., Mamuya, W., Thomson, L., & Weigold, W. G. (2009) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2009.03.004 · Cited by 580
Initial evaluation of coronary images from 320-detector row computed tomography
Rybicki, F. J., Otero, H. J., Steigner, M. L., Vorobiof, G., Nallamshetty, L., Mitsouras, D., Ersoy, H., Mather, R. T., Judy, P. F., Cai, T., et al. (2008) · The International Journal of Cardiovascular Imaging · doi:10.1007/s10554-008-9308-2 · Cited by 563
Schroeder, S., Achenbach, S., Bengel, F., Burgstahler, C., Cademartiri, F., de Feyter, P., George, R., Kaufmann, P., Kopp, A. F., Knuuti, J., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehm544 · Cited by 554
Self-citationFeasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating
Husmann, L., Valenta, I., Gaemperli, O., Adda, O., Treyer, V., Wyss, C. A., Veit-Haibach, P., Tatsugami, F., von Schulthess, G. K., & Kaufmann, P. A. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm613 · Cited by 530
Self-citation
Metadata
- Authors
- Scheffel, H., Alkadhi, H., Plass, A., Vachenauer, R., Desbiolles, L., Gaemperli, O., Schepis, T., Frauenfelder, T., Schertler, T., Husmann, L., Grunenfelder, J., Genoni, M., Kaufmann, P. A., Marincek, B., & Leschka, S.
- Venue
- European Radiology
- Published
- 2006-09-19
- Volume
- 16
- Issue
- 12
- Pages
- 2739-2747
- ISSN
- 0938-7994 (ISSN-L)
- 1432-1084
- OpenAlex
- W2032610614
- Cited by
- 420
- References
- 20
- FWCI
- 55.42
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.