Optimal threshold in CT quantification of emphysema
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
AbstractObjectivesTo determine the optimal threshold by quantitatively assessing the extent of emphysema at the level of the entire lung and at the level of individual lobes using a large, diverse dataset of computed tomography (CT) examinations.MethodsThis study comprises 573 chest CT examinations acquired from subjects with different levels of airway obstruction (222 none, 83 mild, 141 moderate, 63 severe and 64 very severe). The extent of emphysema was quantified using the percentage of the low attenuation area (LAA%) divided by the total lung or lobe volume(s). The correlations between the extent of emphysema, and pulmonary functions and the five-category classification were assessed using Pearson and Spearman’s correlation coefficients, respectively. When quantifying emphysema using a density mask, a wide range of thresholds from −850 to −1,000 HU were used.ResultsThe highest correlations of LAA% with the five-category classification and PFT measures ranged from −925 to −965 HU for each individual lobe and the entire lung. However, the differences between the highest correlations and those obtained at −950 HU are relatively small.ConclusionAlthough there are variations in the optimal cut-off thresholds for individual lobes, the single threshold of −950 HU is still an acceptable threshold for density-based emphysema quantification.Key Points• CT is widely used to assess the severity of emphysema • Density mask technique helps clinicians assess the extent of emphysema with CT • A standardised cut-off for density mask analysis at lobe level is desirable • −950 HU is acceptable for density-based emphysema quantification at the lobar level
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vestbo, J., Hurd, S. S., Agustí, A. G., Jones, P. W., Vogelmeier, C., Anzueto, A., Barnes, P. J., Fabbri, L. M., Martinez, F. J., Nishimura, M., et al. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201204-0596pp · Cited by 15,983
Rabe, K. F., Hurd, S., Anzueto, A., Barnes, P. J., Buist, S. A., Calverley, P., Fukuchi, Y., Jenkins, C., Rodriguez-Roisin, R., van Weel, C., et al. (2007) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200703-456so · Cited by 4,925 · cited 4×
“Subjects that have FEV1/FVC 70 % were classified into GOLD stages I-IV according to the Global Initiative for Obstructive Lung Disease (GOLD) [15].”
MethodInfluentialRabe, K. F. (2007) · American Journal of Respiratory and Critical Care Medicine · Cited by 2,567
Comparison of computed density and macroscopic morphometry in pulmonary emphysema.
Gevenois, P. A., de Maertelaer, V, De Vuyst, P., Zanen, J., & Yernault, J. C. (1995) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.152.2.7633722 · Cited by 882 · cited 1×
“[3] explained that a threshold of −950 HU correlated more closely with the macroscopic pathological features of emphysema.”
BackgroundMüller, N. L., Staples, C. A., Miller, R. R., & Abboud, R. T. (1988) · Chest · doi:10.1378/chest.94.4.782 · Cited by 798 · cited 1×
“[2] suggested a threshold of −910 HU for this density mask analysis.”
BackgroundComputed Tomographic Measurements of Airway Dimensions and Emphysema in Smokers
NAKANO, Y., MURO, S., SAKAI, H., HIRAI, T., CHIN, K., TSUKINO, M., NISHIMURA, K., ITOH, H., PARÉ, P. D., HOGG, J. C., et al. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.3.9907120 · Cited by 695
Madani, A., Maertelaer, V. D., Zanen, J., & Gevenois, P. A. (2007) · Radiology · doi:10.1148/radiol.2431060194 · Cited by 209 · cited 2×
“[8] suggested that a cut-off of −960 HU or −970 HU might yield more accurate assessment of the extent of emphysema.”
BackgroundEmphysema: Effect of Reconstruction Algorithm on CT Imaging Measures
Boedeker, K. L., McNitt-Gray, M. F., Rogers, S. R., Truong, D. A., Brown, M. S., Gjertson, D. W., & Goldin, J. G. (2004) · Radiology · doi:10.1148/radiol.2321030383 · Cited by 190
Impact of Exacerbations on Emphysema Progression in Chronic Obstructive Pulmonary Disease
Tanabe, N., Muro, S., Hirai, T., Oguma, T., Terada, K., Marumo, S., Kinose, D., Ogawa, E., Hoshino, Y., & Mishima, M. (2011) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201009-1535oc · Cited by 182
A Pilot Study of All- trans -Retinoic Acid for the Treatment of Human Emphysema
MAO, J. T., GOLDIN, J. G., DERMAND, J., IBRAHIM, G., BROWN, M. S., EMERICK, A., McNITT-GRAY, M. F., GJERTSON, D. W., ESTRADA, F., TASHKIN, D. P., et al. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.165.5.2106123 · Cited by 175 · cited 1×
“The density of areas of emphysema depicted on computed tomography (CT) typically ranges from −900 to −1,024 Hounsfield Units (HU) [1].”
Background
Metadata
- Authors
- Wang, Z., Gu, S., Leader, J. K., Kundu, S., Tedrow, J. R., Sciurba, F. C., Gur, D., Siegfried, J. M., & Pu, J.
- Venue
- European Radiology
- Published
- 2012-11-01
- Volume
- 23
- Issue
- 4
- Pages
- 975-984
- ISSN
- 0938-7994 (ISSN-L)
- 1432-1084
- OpenAlex
- W2065984169
- Cited by
- 166
- References
- 24
- FWCI
- 2.37
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimal threshold in CT quantification of emphysema. https://app.cochat.ai/papers/10.1007/s00330-012-2683-z
- The paper
- Wang, Z., Gu, S., Leader, J. K., Kundu, S., Tedrow, J. R., Sciurba, F. C., Gur, D., Siegfried, J. M., & Pu, J. (2013). Optimal threshold in CT quantification of emphysema. European Radiology. https://doi.org/10.1007/s00330-012-2683-z
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.