Quantitative assessment of right ventricular function and pulmonary regurgitation in surgically repaired tetralogy of Fallot using 256-slice CT: comparison with 3-Tesla MRI
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Objectives To compare 256-slice cardiac computed tomography (CCT) with cardiac magnetic resonance (CMR) imaging to assess right ventricular (RV) function and pulmonary regurgitant fraction (PRF) in patients with repaired tetralogy of Fallot (TOF).Methods Thirty-three consecutive patients with repaired TOF underwent retrospective ECG-gated CCT and 3-Tesla CMR. RV and left ventricular (LV) end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and ejection fraction (EF) were measured using CCT and CMR. PRF-CCT (%) was defined as (RVSV - LVSV)/RVSV. PRF-CMR (%) was measured by the phase-contrast method. Repeated measurements were performed to determine intra- and interobserver variability.Results CCT measurements, including PRF, correlated highly with the CMR reference (r = 0.71-0.96). CCT overestimated RVEDV (mean difference, 17.1 ± 2.9 ml), RVESV (12.9 ± 2.1 ml) and RVSV (4.2 ± 2.0 ml), and underestimated RVEF (-2.6 ± 1.0%) and PRF (-9.1 ± 2.0%) compared with CMR. The limits of agreement between CCT and CMR were in a good range for all measurements. The variability in CCT measurements was lower than those in CMR. The estimated effective radiation dose was 7.6 ± 2.6 mSv.Conclusions 256-slice CCT can assess RV function and PRF with relatively low dose radiation exposure in patients with repaired TOF, but overestimates RV volume and underestimates PRF.Key points 256-slice CT assessment of RV function is highly reproducible in repaired TOF. Pulmonary regurgitation can be evaluated by biventricular systolic volume difference. CT overestimates RV volume and underestimates pulmonary regurgitation, compared with MRI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Firstly, it allows for a rapid and precise visualisation of the cardiac anatomy, including the extent of the VSD, the degree of PAS, and the position of the aorta [57,59,60]. Secondly, CCT angiography enables the assessment of coronary artery anomalies, which are common in patients with TOF and play a crucial role in surgical planning [61]. Moreover, CCT provides valuable functional information,”
From Multimodality imaging assessment of tetralogy of Fallot: From diagnosis to long-term follow-up (2023) · cites this paper as [57]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ESC Guidelines for the management of grown-up congenital heart disease (new version 2010)
Endorsed by the Association for European Paediatric Cardiology (AEPC), Authors/Task Force Members, Baumgartner, H., Bonhoeffer, P., De Groot, N. M. S., de Haan, F., Deanfield, J. E., Galie, N., Gatzoulis, M. A., Gohlke-Baerwolf, C., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq249 · Cited by 2,331
Warnes, C. A., Williams, R. G., Bashore, T. M., Child, J. S., Connolly, H. M., Dearani, J. A., del Nido, P., Fasules, J. W., Graham, T. P., Hijazi, Z. M., et al. (2008) · Circulation · doi:10.1161/circulationaha.108.190811 · Cited by 2,066
Congenital Heart Disease in the General Population: Changing Prevalence and Age Distribution
Marelli, A. J., Mackie, A. S., Ionescu-Ittu, R., Rahme, E., & Pilote, L. (2007) · Circulation · doi:10.1161/circulationaha.106.627224 · Cited by 1,747 · cited 4×
“In 2000, there were nearly equal numbers of adults and children with severe CHD [15].”
BackgroundInfluentialWarnes, C. A., Williams, R. G., Bashore, T. M., Child, J. S., Connolly, H. M., Dearani, J. A., del Nido, P., Fasules, J. W., Graham, T. P., Hijazi, Z. M., et al. (2008) · Circulation · doi:10.1161/circulationaha.108.190690 · Cited by 867
Hausleiter, J., Meyer, T., Hadamitzky, M., Huber, E., Zankl, M., Martinoff, S., Kastrati, A., & Schömig, A. (2006) · Circulation · doi:10.1161/circulationaha.105.602490 · Cited by 705
Geva, T. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-9 · Cited by 582
Earls, J. P., Berman, E. L., Urban, B. A., Curry, C. A., Lane, J. L., Jennings, R. S., McCulloch, C. C., Hsieh, J., & Londt, J. H. (2008) · Radiology · doi:10.1148/radiol.2463070989 · Cited by 543
Mooij, C. F., de Wit, C. J., Graham, D. A., Powell, A. J., & Geva, T. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21407 · Cited by 297 · cited 1×
“As previously reported, CMR measurements of RVand LV function are highly reproducible in patients with both normal and dilated right ventricles [21].”
MethodReoperation in adults with repair of tetralogy of Fallot: indications and outcomes.
Oechslin, E. N., Harrison, D. A., Harris, L., Downar, E., Webb, G. D., Siu, S. S., & Williams, W. G. (1999) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(99)70214-x · Cited by 264
Lee, C., Kim, Y. M., Lee, C.-H., Kwak, J. G., Park, C. S., Song, J. Y., Shim, W.-S., Choi, E. Y., Lee, S. Y., & Baek, J. S. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.03.077 · Cited by 246
Cited by
Zoghbi, W. A., Asch, F. M., Bruce, C., Gillam, L. D., Grayburn, P. A., Hahn, R. T., Inglessis, I., Islam, A. M., Lerakis, S., Little, S. H., et al. (2019) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2019.01.003 · Cited by 439
Han, B. K., Rigsby, C. K., Hlavacek, A., Leipsic, J., Nicol, E. D., Siegel, M. J., Bardo, D., Abbara, S., Ghoshhajra, B., Lesser, J. R., et al. (2015) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2015.07.004 · Cited by 211
Han, B. K., Rigsby, C. K., Leipsic, J., Bardo, D., Abbara, S., Ghoshhajra, B., Lesser, J. R., Raman, S. V., Crean, A. M., Nicol, E. D., et al. (2015) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2015.07.007 · Cited by 158
Yamasaki, Y., Nagao, M., Abe, K., Hosokawa, K., Kawanami, S., Kamitani, T., Yamanouchi, T., Horimoto, K., Yabuuchi, H., & Honda, H. (2016) · International journal of cardiac imaging · doi:10.1007/s10554-016-0985-y · Cited by 64
Self-citationPulmonary valve replacement after repaired Tetralogy of Fallot
Tatewaki, H., & Shiose, A. (2018) · General Thoracic and Cardiovascular Surgery · doi:10.1007/s11748-018-0931-0 · Cited by 61
Kim, J. Y., Suh, Y. J., Han, K., Kim, Y. J., & Choi, B. W. (2020) · Korean Journal of Radiology · doi:10.3348/kjr.2019.0499 · Cited by 46
“The CT reconstruction interval was 10% and 5% of the RR intervals in 10 studies (6, 11, 13, 17-19, 21-23, 27) and 9 studies (12, 14-16, 20, 21, 25, 28, 29), respectively.”
BackgroundMethodResultInfluentialGoo, H. W. (2018) · Korean Journal of Radiology · doi:10.3348/kjr.2018.0237 · Cited by 39
“Sheehan FH, Kilner PJ, Sahn DJ, Vick GW 3rd, Stout KK, Ge S, et al. Accuracy of knowledge-based reconstruction for measurement of right ventricular volume and function in patients with tetralogy of Fallot.”
BackgroundResultInfluentialMultimodality Imaging of Transposition of the Great Arteries
Canan, A., Ashwath, R. C., Agarwal, P., François, C. J., & Rajiah, P. S. (2021) · Radiographics · doi:10.1148/rg.2021200069 · Cited by 26
Fu, H., Wang, X., Diao, K., Huang, S., Liu, H., Gao, Y., Zhao, Q., Yang, Z., & Guo, Y. (2019) · European Radiology · doi:10.1007/s00330-019-06228-2 · Cited by 24
Computed tomography in tetralogy of Fallot: Pre- and postoperative imaging evaluation
Zucker, E. J. (2022) · Pediatric Radiology · doi:10.1007/s00247-021-05179-5 · Cited by 23
Dose optimization in cardiac CT
Hedgire, S., Ghoshhajra, B. B., & Kalra, M. K. (2017) · Physica Medica · doi:10.1016/j.ejmp.2017.04.021 · Cited by 27
Yamasaki, Y., Nagao, M., Kamitani, T., Yamanouchi, T., Kawanami, S., Yamamura, K., Sakamoto, I., Yabuuchi, H., & Honda, H. (2016) · European Radiology · doi:10.1007/s00330-015-4199-9 · Cited by 22
“Cardiac MRI has now become popular to evaluate right-sided heart disease, because this modality can measure RV volume and EF accurately and non-invasively, even in CHD patients [16, 17].”
BackgroundSelf-citationGroves, D. W., Olivieri, L., Shanbhag, S. M., Bronson, K. C., Yu, J. H., Nelson, E. A., Rollison, S. F., Stagliano, M. S., John, A. S., KUEHL, K. S., et al. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2016.11.108 · Cited by 25
Contijoch, F. J., Groves, D. W., Chen, Z., Chen, M. Y., & McVeigh, E. R. (2017) · International Journal of Cardiology · doi:10.1016/j.ijcard.2017.08.040 · Cited by 20
“[7] Y. Yamasaki, M. Nagao, K. Yamamura, M. Yonezawa, Y. Matsuo, S. Kawanami, 415 T. Kamitani, K. Higuchi, I. Sakamoto, Y. Shiokawa, H. Yabuuchi, H. Honda, Quantitative assessment of right ventricular function and pulmonary regurgitation in surgically repaired tetralogy of Fallot using 256-slice CT: comparison with 3-…”
BackgroundInfluentialPeper, J., Suchá, D., Swaans, M. J., & Leiner, T. (2020) · British Journal of Radiology · doi:10.1259/bjr.20200349 · Cited by 19
Multimodality imaging assessment of tetralogy of Fallot: From diagnosis to long-term follow-up
Moscatelli, S., Pergola, V., Motta, R., Fortuni, F., Borrelli, N., Sabatino, J., Leo, I., Avesani, M., Montanaro, C., Surkova, E., et al. (2023) · Children · doi:10.3390/children10111747 · Cited by 17
“Firstly, it allows for a rapid and precise visualisation of the cardiac anatomy, including the extent of the VSD, the degree of PAS, and the position of the aorta [57,59,60].”
BackgroundMethodNagao, M., Yamasaki, Y., Abe, K., Hosokawa, K., Kawanami, S., Kamitani, T., Yamanouchi, T., Yabuuchi, H., Fukushima, K., & Honda, H. (2016) · European Journal of Radiology · doi:10.1016/j.ejrad.2016.12.015 · Cited by 16
Self-citationOne-stop shop assessment for atrial septal defect closure using 256-slice coronary CT angiography
Yamasaki, Y., Nagao, M., Kawanami, S., Kamitani, T., Sagiyama, K., Yamanouchi, T., Sakamoto, I., Yamamura, K., Yabuuchi, H., & Honda, H. (2016) · European Radiology · doi:10.1007/s00330-016-4407-2 · Cited by 16
“with low-dose radiation exposure in congenital heart disease [3, 4].”
BackgroundSelf-citationCardiovascular computed tomography in pediatric congenital heart disease: A state of the art review
Cohen, J. L., Asrani, P., Lee, S., Frush, D. P., Han, B., Chelliah, A., & Farooqi, K. M. (2022) · Journal of cardiovascular computed tomography · doi:10.1016/j.jcct.2022.04.004 · Cited by 18
Flors, L., Bueno, J., Gish, D., White, S. C., Norton, P. T., Hagspiel, K. D., & Leiva‐Salinas, C. (2020) · Journal of Thoracic Imaging · doi:10.1097/rti.0000000000000478 · Cited by 19
Shiina, Y., Taniguchi, K., Nagao, M., Takahashi, T., Niwa, K., Kawakubo, M., & Inai, K. (2019) · Journal of Cardiology · doi:10.1016/j.jjcc.2019.09.009 · Cited by 13
Self-citationMagalhães, T. A., Carneiro, A. C. D. C., Moreira, V. D. M., Trad, H. S., Uellendahl, M. M., Cerci, R., Nacif, M. S., Schvartzman, P. R., Chagas, A. C. P., Costa, I. B. S. D. S., et al. (2024) · Arquivos Brasileiros de Cardiologia · doi:10.36660/abc.20240608i · Cited by 12
Lesser, A. M., Newell, M. C., Samara, M. A., Gornick, C. C., Grant, K. L. R., Garberich, R., & Han, B. (2015) · Journal of cardiovascular computed tomography · doi:10.1016/j.jcct.2015.12.009 · Cited by 12
Kido, T., Ueno, T., Taira, M., Ozawa, H., Toda, K., Kuratani, T., & Sawa, Y. (2018) · Circulation Journal · doi:10.1253/circj.cj-17-1088 · Cited by 15
Ishizaki, U., Nagao, M., Shiina, Y., Fukushima, K., Takahashi, T., Shimomiya, Y., Matsuo, Y., Inai, K., & Sakai, S. (2018) · Circulation Journal · doi:10.1253/circj.cj-17-1260 · Cited by 10
Self-citationGuo, F., Wu, B.-L., Liu, X., Pan, T., Gao, B., & Li, C. (2023) · Medicine · doi:10.1097/md.0000000000033549 · Cited by 8
“Inter-modality differences in the ability to visualize the endocardial boundary details and to include or exclude prominent trabeculae may also affect accurate measurement of the left ventricular volume and function.[16,27] In a study with 179 patients, significant differences were observed in the left ventricular par…”
BackgroundCardiovascular CT in Cyanotic Congenital Heart Disease
Chelliah, A., Shah, A. M., Farooqi, K. M., Einstein, A. J., & Han, B. (2019) · Current Cardiovascular Imaging Reports · doi:10.1007/s12410-019-9507-3 · Cited by 8
Ohashi, R., Nagao, M., Ishizaki, U., Shiina, Y., Inai, K., & Sakai, S. (2019) · Pediatric Cardiology · doi:10.1007/s00246-019-02272-3 · Cited by 5
Self-citationXu, J., Tian, Y., Wang, J., Xu, W., Shi, Z., Fu, J., & Shu, Q. (2019) · World Journal of Pediatric Surgery · doi:10.1136/wjps-2019-000073 · Cited by 5
Patel, N. R., Cohen, J. L., Rajagopal, H. G., Barris, D. M., Stern, K. W. D., Choueiter, N. F., Hopkins, K., LaRocca, G., Jacobi, A., Love, B., et al. (2025) · Journal of cardiovascular computed tomography · doi:10.1016/j.jcct.2025.06.009 · Cited by 4
Xie, W., Guo, C., Hu, L., Ouyang, R., Yao, X., Sun, A., Qiu, H., Yan, Q., Zhu, Y., Wang, Q., et al. (2021) · Journal of Computer Assisted Tomography · doi:10.1097/rct.0000000000001155 · Cited by 4
Andreini, D., Conte, E., Mushtaq, S., Pontone, G., Guglielmo, M., Baggiano, A., Annoni, A. D., Mancini, M. E., Formenti, A., Nicoli, F., et al. (2020) · Journal of Cardiovascular Medicine · doi:10.2459/jcm.0000000000001051 · Cited by 4
Xie, W., Chen, L., Hu, L., Ouyang, R., Guo, C., Sun, A., Wang, Q., Qiu, H., Qin, Y., Zhang, Y., et al. (2021) · European Journal of Radiology · doi:10.1016/j.ejrad.2021.109868 · Cited by 3
Magalhães, T. A., Carneiro, A. C. D. C., Moreira, V. D. M., Trad, H. S., Uellendahl, M. M., Cerci, R., Nacif, M. S., Schvartzman, P. R., Chagas, A. C. P., Costa, I. B. S. D. S., et al. (2024) · Arquivos Brasileiros de Cardiologia · doi:10.36660/abc.20240608 · Cited by 30
Lin, W.-H., Luo, F.-R., Cai, Y.-Y., Xiao, H.-J., & Huang, Q.-W. (2023) · BMC Cardiovascular Disorders · doi:10.1186/s12872-023-03635-8 · Cited by 2
“In recent years, cardiac CTA has experienced significant technological advancements, enabling detailed cardiac structural scanning and reconstruction for congenital heart disease with reduced radiation exposure [17, 18].”
BackgroundCardiothoracic Surgery Applications: Virtual CT Imaging Approaches to Procedural Planning
Shinbane, J. S., Baker, C. J., Cunningham, M. J., & Starnes, V. A. (2016) · Springer eBooks · doi:10.1007/978-3-319-28219-0_22 · Cited by 1
Cardiac Computed Tomography in Evaluation of Ventricular Function
Kharouf, R. M., & Adebo, D. A. (2021) · Springer eBooks · doi:10.1007/978-3-030-74822-7_29 · Cited by 1
Shimomiya, Y., Nagao, M., Kogure, T., Asagai, S., Inoue, A., Yamamoto, A., Sakai, S., Inai, K., Shirasaka, T., Kojima, T., et al. (2024) · Circulation Journal · doi:10.1253/circj.cj-24-0386 · Cited by 1
Self-citationCardiac-CT in 2017: Over the coronary artery assessment
Andreini, D., Conte, E., & Mushtaq, S. (2017) · International Journal of Cardiology · doi:10.1016/j.ijcard.2017.09.177
Sato, T., Sakamoto, I., Hiasa, K., Kawakubo, M., Ishikita, A., Umemoto, S., Kang, M., Sawatari, H., Chishaki, A., Shigeto, H., et al. (2022) · The International Journal of Cardiovascular Imaging · doi:10.1007/s10554-022-02712-x
“In the software, RV endocardial borders were contoured with myocardial trabeculations, moderator band, and papillary muscles included in the cavity, as previously reported [19, 20].”
MethodSelf-citationGoo, H. W., Park, S. H., & Goo, S. Y. (2024) · Pediatric Cardiology · doi:10.1007/s00246-024-03570-1
“However, based on prior studies, this variability is expected to be low (3.5 ‒ 7.3% and 3.4 ‒ 7.6%, respectively) [28].”
InfluentialAutomated Estimation of Cardiac Stroke Volumes from Computed Tomography
Radutoiu, A.-T., Youssef, Y. W. E., Diez, P. L., Sørensen, K. A., Lindeskog, M. B., Pham, M. H. C., Pedersen, J. J., Fuchs, A., Kofoed, K. F., & Paulsen, R. R. (2025) · Lecture notes in computer science · doi:10.1007/978-3-031-87756-8_3
Goo, H. W. (2025) · Journal of cardiovascular computed tomography · doi:10.1016/j.jcct.2025.05.236
Goo, H. W. (2025) · European Journal of Radiology · doi:10.1016/j.ejrad.2025.112541
Quantitative Techniques in Cardiac MRI
Modi, V. A., Dhore-Patil, A., Chao, M.-F., Chang, S. M., & Shah, D. J. (2026) · Springer eBooks · doi:10.1007/978-3-032-14103-3_2
Alloah, Q., Fishbein, J. S., Cohen, J., Christopher, A., Beroukhim, R. S., Lee, S., Han, B. K., & Rajagopal, H. G. (2026) · Journal of Cardiovascular Magnetic Resonance · doi:10.1016/j.jocmr.2026.102821
Metadata
- Authors
- Yamasaki, Y., Nagao, M., Yamamura, K., Yonezawa, M., Matsuo, Y., Kawanami, S., Kamitani, T., Higuchi, K., Sakamoto, I., Shiokawa, Y., Yabuuchi, H., & Honda, H.
- Affiliations
- Kyushu University (JP)
- Corresponding author
- Nagao, Michinobu
- ORCID
- Venue
- European Radiology
- Published
- 2014-08-12
- Volume
- 24
- Issue
- 12
- Pages
- 3289-3299
- ISSN
- 0938-7994 (ISSN-L)
- 1432-1084
- OpenAlex
- W2073139568
- Cited by
- 46
- References
- 29
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 4 · 2023: 3 · 2022: 2 · 2021: 5 · 2020: 4 · 2019: 6 · 2018: 4 · 2017: 3 · 2016: 6 · 2015: 3
- FWCI
- 3.02
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- European Radiology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Japan Society for the Promotion of Science (25461831)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Congenital Heart Disease Studies
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Valve Diseases and Treatments
- Keywords
- repaired tetralogy of Fallot, right ventricular function, pulmonary regurgitation, cardiac magnetic resonance, ECG-gated CT, right ventricular ejection fraction, right ventricular volume, radiation dose, interobserver variability
- MeSH terms
- Adult, Female, Follow-Up Studies, Cardiac Surgical Procedures, Humans, Image Processing, Computer-Assisted, Male, Pulmonary Valve Insufficiency, Retrospective Studies, Stroke Volume, Systole, Tetralogy of Fallot, Ventricular Function, Right, Magnetic Resonance Imaging, Cine, Multidetector Computed Tomography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.