CoChat

Precise diagnosis of intracranial hemorrhage and subtypes using a three-dimensional joint convolutional and recurrent neural network

Open access
Ye, Hai, Gao, Feng, Yin, Youbing, Guo, Danfeng, Zhao, Pengfei, Lu, Yi, Wang, Xin, Bai, Junjie, Cao, Kunlin, Song, Qi, Zhang, Heye, Chen, Wei, Guo, Xuejun, Xia, Jun · 2019 · European Radiology
Cited by 244

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: To evaluate the performance of a novel three-dimensional (3D) joint convolutional and recurrent neural network (CNN-RNN) for the detection of intracranial hemorrhage (ICH) and its five subtypes (cerebral parenchymal, intraventricular, subdural, epidural, and subarachnoid) in non-contrast head CT. METHODS: A total of 2836 subjects (ICH/normal, 1836/1000) from three institutions were included in this ethically approved retrospective study, with a total of 76,621 slices from non-contrast head CT scans. ICH and its five subtypes were annotated by three independent experienced radiologists, with majority voting as reference standard for both the subject level and the slice level. Ninety percent of data was used for training and validation, and the rest 10% for final evaluation. A joint CNN-RNN classification framework was proposed, with the flexibility to train when subject-level or slice-level labels are available. The predictions were compared with the interpretations from three junior radiology trainees and an additional senior radiologist. RESULTS: It took our algorithm less than 30 s on average to process a 3D CT scan. For the two-type classification task (predicting bleeding or not), our algorithm achieved excellent values (≥ 0.98) across all reporting metrics on the subject level. For the five-type classification task (predicting five subtypes), our algorithm achieved > 0.8 AUC across all subtypes. The performance of our algorithm was generally superior to the average performance of the junior radiology trainees for both two-type and five-type classification tasks. CONCLUSIONS: The proposed method was able to accurately detect ICH and its subtypes with fast speed, suggesting its potential for assisting radiologists and physicians in their clinical diagnosis workflow. KEY POINTS: • A 3D joint CNN-RNN deep learning framework was developed for ICH detection and subtype classification, which has the flexibility to train with either subject-level labels or slice-level labels. • This deep learning framework is fast and accurate at detecting ICH and its subtypes. • The performance of the automated algorithm was superior to the average performance of three junior radiology trainees in this work, suggesting its potential to reduce initial misinterpretations.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s00330-019-06163-2

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 4

  1. Alfaro D, Levitt MA, English DK, Williams V, Eisenberg R (1995) Accuracy of interpretation of cranial computed tomography scans in an emergency medicine residency program. Ann Emerg Med 25:169–174 · doi:10.1016/s0196-0644(95)70319-5
  2. Lal NR, Murray UM, Eldevik OP, Desmond JS (2000) Clinical consequences of misinterpretations of neuroradiologic CT scans by on-call radiology residents. AJNR Am J Neuroradiol 21:124–129
  3. Araújo JLV, Aguiar UP, Todeschini AB, Saade N, Veiga JCE (2012) Epidemiological analysis of 210 cases of surgically treated traumatic extradural hematoma. Rev Col Bras Cir 39(4):268–271 · doi:10.1590/s0100-69912012000400005
  4. Kim ES, Yoon DY, Lee H-Y et al (2014) Comparison of emergency cranial CT interpretation between radiology residents and neuroradiologists: transverse versus three-dimensional images. Diagn Interv Radiol 20(3):277–284 · doi:10.5152/dir.2014.13401

Cited by

See all 244

Metadata

Authors
Ye, H., Gao, F., Yin, Y., Guo, D., Zhao, P., Lu, Y., Wang, X., Bai, J., Cao, K., Song, Q., Zhang, H., Chen, W., Guo, X., & Xia, J.
Venue
European Radiology
Published
2019-04-30
Volume
29
Issue
11
Pages
6191-6201
ISSN
  • 0938-7994 (ISSN-L)
  • 1432-1084
OpenAlex
W2943644689
Cited by
244
References
30
FWCI
16.71
Type
journal article
Language
en
Open access
hybrid
Licence
creativecommons.org/licenses/by/4.0 (tdm)
Funders
  • Science and Technology Planning Project of Guangdong Province (2017A020215160)
  • Shenzhen Municipal Government (KQTD2016112809330877)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.