Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.

Automated deep-neural-network surveillance of cranial images for acute neurologic events

Abstract

Rapid diagnosis and treatment of acute neurological illnesses such as stroke, hemorrhage, and hydrocephalus are critical to achieving positive outcomes and preserving neurologic function-'time is brain'1-5. Although these disorders are often recognizable by their symptoms, the critical means of their diagnosis is rapid imaging 6-10. Computer-aided surveillance of acute neurologic events in cranial imaging has the potential to triage radiology workflow, thus decreasing time to treatment and improving outcomes. Substantial clinical work has focused on computer-assisted diagnosis (CAD), whereas technical work in volumetric image analysis has focused primarily on segmentation. 3D convolutional neural networks (3D-CNNs) have primarily been used for supervised classification on 3D modeling and light detection and ranging (LiDAR) data 11-15. Here, we demonstrate a 3D-CNN architecture that performs weakly supervised classification to screen head CT images for acute neurologic events. Features were automatically learned from a clinical radiology dataset comprising 37,236 head CTs and were annotated with a semisupervised natural-language processing (NLP) framework 16. We demonstrate the effectiveness of our approach to triage radiology workflow and accelerate the time to diagnosis from minutes to seconds through a randomized, double-blinded, prospective trial in a simulated clinical environment.

Overview

Integrity signals

Registry

Crossref · 10.1038/s41591-018-0147-y

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 41 references

Research works printed but not linked: 1

  1. Hegde, V. & Zadeh, R. FusionNet: 3D object classification using multiple data representations. Preprint at https://arxiv.org/abs/1607.05695/ (2016). · arXiv

Cited by

See all 465

Metadata

Authors
Titano, J. J., Badgeley, M., Schefflein, J., Pain, M., Su, A., Cai, M., Swinburne, N., Zech, J., Kim, J., Bederson, J., Mocco, J., Drayer, B., Lehar, J., Cho, S., Costa, A., & Oermann, E. K.
Affiliations
Icahn School of Medicine at Mount Sinai (US)
Corresponding author
Oermann, Eric K.
Venue
Nature Medicine
Published
2018-08-13
Volume
24
Issue
9
Pages
1337-1341
ISSN
  • 1078-8956 (ISSN-L)
  • 1546-170X
OpenAlex
W2885688423
Cited by
458
References
41
Citations by year
2026: 28 · 2025: 31 · 2024: 71 · 2023: 48 · 2022: 63 · 2021: 91 · 2020: 65 · 2019: 48 · 2018: 12
FWCI
14.64
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • Nature Medicine (publishedVersion)
  • PubMed (publishedVersion)
Funders
U.S. National Library of Medicine
Topics
  • Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
  • Health Sciences › Medicine › Clinical Neurology › Acute Ischemic Stroke Management
  • Physical Sciences › Computer Science › Artificial Intelligence › Machine Learning in Healthcare
Keywords
head CT, 3D convolutional neural networks, weakly supervised classification, computer-aided diagnosis, stroke, intracranial hemorrhage, hydrocephalus, automated image classification
MeSH terms
Algorithms, Automation, Humans, ROC Curve, Skull, Tomography, X-Ray Computed, Randomized Controlled Trials as Topic, Neural Networks, Computer, Imaging, Three-Dimensional

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automated deep-neural-network surveillance of cranial images for acute neurologic events. https://app.cochat.ai/papers/10.1038/s41591-018-0147-y
The paper
Titano, J. J., Badgeley, M., Schefflein, J., Pain, M., Su, A., Cai, M., Swinburne, N., Zech, J., Kim, J., Bederson, J., Mocco, J., Drayer, B., Lehar, J., Cho, S., Costa, A., & Oermann, E. K. (2018). Automated deep-neural-network surveillance of cranial images for acute neurologic events. Nature Medicine. https://doi.org/10.1038/s41591-018-0147-y

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.