The DOI matches its Crossref record; 60 of the 60 references it cites were found in a registry or an index.
Diffusion-weighted imaging of the breast—a consensus and mission statement from the EUSOBI International Breast Diffusion-Weighted Imaging working group
Open accessAbstract
The European Society of Breast Radiology (EUSOBI) established an International Breast DWI working group. The working group consists of clinical breast MRI experts, MRI physicists, and representatives from large vendors of MRI equipment, invited based upon proven expertise in breast MRI and/or in particular breast DWI, representing 25 sites from 16 countries. The aims of the working group are (a) to promote the use of breast DWI into clinical practice by issuing consensus statements and initiate collaborative research where appropriate; (b) to define necessary standards and provide practical guidance for clinical application of breast DWI; (c) to develop a standardized and translatable multisite multivendor quality assurance protocol, especially for multisite research studies; (d) to find consensus on optimal methods for image processing/analysis, visualization, and interpretation; and (e) to work collaboratively with system vendors to improve breast DWI sequences. First consensus recommendations, presented in this paper, include acquisition parameters for standard breast DWI sequences including specifications of b values, fat saturation, spatial resolution, and repetition and echo times. To describe lesions in an objective way, levels of diffusion restriction/hindrance in the breast have been defined based on the published literature on breast DWI. The use of a small ROI placed on the darkest part of the lesion on the ADC map, avoiding necrotic, noisy or non-enhancing lesion voxels is currently recommended. The working group emphasizes the need for standardization and quality assurance before ADC thresholds are applied. The working group encourages further research in advanced diffusion techniques and tailored DWI strategies for specific indications. Key Points • The working group considers breast DWI an essential part of a multiparametric breast MRI protocol and encourages its use. • Basic requirements for routine clinical application of breast DWI are provided, including recommendations on b values, fat saturation, spatial resolution, and other sequence parameters. • Diffusion levels in breast lesions are defined based on meta-analysis data and methods to obtain a reliable ADC value are detailed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PI-RADS Prostate Imaging – Reporting and Data System: 2015, Version 2
Weinreb, J. C., Barentsz, J. O., Choyke, P. L., Cornud, F., Haider, M. A., Macura, K. J., Margolis, D., Schnall, M. D., Shtern, F., Tempany, C. M., et al. (2016) · European Urology · doi:10.1016/j.eururo.2015.08.052 · Cited by 2,951
Breast imaging reporting and data system (BI-RADS)
Liberman, L., & Menell, J. H. (2002) · Radiologic Clinics of North America · doi:10.1016/s0033-8389(01)00017-3 · Cited by 2,155
Magnetic resonance imaging of the breast: Recommendations from the EUSOMA working group
Sardanelli, F., Boetes, C., Borisch, B., Decker, T., Federico, M., Gilbert, F. J., Helbich, T., Heywang-Köbrunner, S. H., Kaiser, W. A., Kerin, M. J., et al. (2010) · European Journal of Cancer · doi:10.1016/j.ejca.2010.02.015 · Cited by 992
Self-citationBreast MRI: guidelines from the European Society of Breast Imaging
Mann, R. M., Kuhl, C. K., Kinkel, K., & Boetes, C. (2008) · European Radiology · doi:10.1007/s00330-008-0863-7 · Cited by 839
Self-citationPorter, D. A., & Heidemann, R. M. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22024 · Cited by 593
Image reconstruction in SNR units: A general method for SNR measurement†
Kellman, P., & McVeigh, E. R. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20713 · Cited by 535
Le Bihan, D. (2013) · Radiology · doi:10.1148/radiol.13130420 · Cited by 397
Self-citationDiffusion changes precede size reduction in neoadjuvant treatment of breast cancer
Pickles, M. D., Gibbs, P., Lowry, M., & Turnbull, L. W. (2006) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2005.11.005 · Cited by 370
Diffusion-weighted breast MRI: Clinical applications and emerging techniques
Partridge, S. C., Nissan, N., Rahbar, H., Kitsch, A. E., & Sigmund, E. E. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25479 · Cited by 340
Self-citationADC Mapping of Benign and Malignant Breast Tumors
WOODHAMS, R., MATSUNAGA, K., KAN, S., HATA, H., OZAKI, M., IWABUCHI, K., KURANAMI, M., WATANABE, M., & HAYAKAWA, K. (2005) · Magnetic Resonance in Medical Sciences · doi:10.2463/mrms.4.35 · Cited by 329
Cited by
Current State of Breast Cancer Diagnosis, Treatment, and Theranostics
Bhushan, A., Gonsalves, A., & Menon, J. U. (2021) · Pharmaceutics · doi:10.3390/pharmaceutics13050723 · Cited by 298
Huang, Y., Wei, L., Hu, Y., Shao, N., Lin, Y., He, S., Shi, H., Zhang, X., & Lin, Y. (2021) · Frontiers in Oncology · doi:10.3389/fonc.2021.706733 · Cited by 82
Metadata
- Authors
- On behalf of the EUSOBI international Breast Diffusion-Weighted Imaging working group, Baltzer, P., Mann, R. M., Iima, M., Sigmund, E. E., Clauser, P., Gilbert, F. J., Martincich, L., Partridge, S. C., Patterson, A., Pinker, K., Thibault, F., Camps-Herrero, J., & Le Bihan, D.
- Venue
- European Radiology
- Published
- 2019-11-30
- Volume
- 30
- Issue
- 3
- Pages
- 1436-1450
- ISSN
- 0938-7994 (ISSN-L)
- 1432-1084
- OpenAlex
- W2991278755
- Cited by
- 437
- References
- 60
- FWCI
- 25.20
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diffusion-weighted imaging of the breast—a consensus and mission statement from the EUSOBI International Breast Diffusion-Weighted Imaging working group. https://app.cochat.ai/papers/10.1007/s00330-019-06510-3
- The paper
- On behalf of the EUSOBI international Breast Diffusion-Weighted Imaging working group, Baltzer, P., Mann, R. M., Iima, M., Sigmund, E. E., Clauser, P., Gilbert, F. J., Martincich, L., Partridge, S. C., Patterson, A., Pinker, K., Thibault, F., Camps-Herrero, J., & Le Bihan, D. (2020). Diffusion-weighted imaging of the breast—a consensus and mission statement from the EUSOBI International Breast Diffusion-Weighted Imaging working group. European Radiology. https://doi.org/10.1007/s00330-019-06510-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.